40W Single Output LED Power Supply PLM-40 series IP30 0 123 & 123 & 123 & 123 & %& ( ) * + ( , - . / & ) ( ( 14 5 5 . 63 123 ( - )14 5 & & ( & - - ) ( & & ( ( ( - .) & & )14 5 ( & & 2 7 2 8 & 9 -14 5 ( & * ( & ( & & 81 5 - :& I6 ( & ( 0 & & ( - :( ( & 14 5 ) (& & << = ) 14 5 2 ) (& & <> = -:& ( & ) ( & & ) ) ) < ) <5 < ) - 0 << = 2 <> = ( % File Name:PLM-40-SPEC 2018-05-0240W Single Output LED Power Supply PLM-40 series SPECIFICATION MODEL PLM-40 -350 PLM-40 -500 PLM-40 -700 PLM-40 -1050 PLM-40 -1400 PLM-40 -1750 RATED CURRENT 350mA 500mA 700mA 1050mA 1400mA 1750mA OPERATING VOLTAGE RANGE Note.5 53 ~ 105V 40 ~ 80V 29 ~ 57V 19 ~ 38V 15 ~ 29V 12 ~ 23V CURRENT ACCURACY Note.3 8.0% RATED POWER 36.75W 40W 39.9W 39.9W 40.6W 40.25W OUTPUT RIPPLE & NOISE (max.) Note.2 10Vp-p 8Vp-p 6Vp-p 4Vp-p 3Vp-p 2.5Vp-p 115V 86V 63V 43V 34V 27V NO LOAD OUTPUT VOLTAGE (max.) SETUP TIME Blank Type: 500ms /115VAC, 230VAC at full load E Type: 500ms / 230VAC at full load Blank Type: 110 ~ 295VAC 156 ~ 417VDC E Type: 180 ~ 295VAC 254 ~ 417VDC VOLTAGE RANGE Note.4 FREQUENCY RANGE 47 ~ 63Hz Blank type PF0.97/115VAC,PF 0.95/230VAC,PF>0.9/277VAC(at full load)(Please refer toPower Factor Characteristi curve) POWER FACTOR (Typ.) PF0.95/230VAC,PF>0.9/277VAC(at full load)(Please refer toPower Factor Characteristi curve) E type Blank type THD< 20% when output loading60% at 115VAC/230VAC input and output loading 75% at 277VAC input TOTAL HARMONIC INPUT DISTORTION E type THD< 20% when output loading60% at 230VAC input and output loading 75% at 277VAC input EFFICIENCY (Typ.) 88% 88% 87% 87% 86% 86% AC CURRENT (Typ.) Blank Type: 0.5A/115VAC 0.3A/230VAC 0.25A/277VAC E Type: 0.3A/230VAC 0.25A/277VAC INRUSH CURRENT(Typ.) COLD START 15A(twidth=75s measured at 50% Ipeak) at 230VAC MAX. No. of PSUs on 16A 47 units (circuit breaker of type B) / 47 units (circuit breaker of type C) at 230VAC CIRCUIT BREAKER <0.5mA / 240VAC LEAKAGE CURRENT Hiccup mode, recovers automatically after fault condition is removed. SHORT CIRCUIT PROTECTION OVER TEMPERATURE Hiccup mode, recovers automatically after temperature goes down. -30 ~ +40 (Refer toDerating Curv) WORKING TEMP. 20 ~ 95% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80, 10 ~ 95% RH TEMP. COEFFICIENT 0.06%/ (0 ~ 40) VIBRATION 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes SAFETY STANDARDS UL8750, CSA C22.2 No. 250.13-12 ENEC EN61347-1, EN61347-2-13, EN62384,GB19510.14,GB19510.1,EAC TP TC 004,IP30 approved WITHSTAND VOLTAGE I/P-O/P:3.75KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH EMC EMC EMISSION Compliance to EN55015, GB17743, GB17625.1,EN61000-3-2 Class C (75% load) EN61000-3-3,EAC TP TC 020 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level, criteria B (Surge 2KV),EAC TP TC 020 EMC IMMUNITY MTBF 822.7Khrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 175*42*24mm (L*W*H) 0.175Kg 60pcs/11.5kg/0.68CUFT PACKING <- + : ) - NOTE - A B 4/C ( & < D ( ( ( & -< B 5 - - - & - 5- 3 ( ) & 0 & & - - ( & E =< E - :& & 123 ) 7 - F- :& ( & ( ( & 7 - % 24 ( & ) & 7 7 24 3 & - - 3 123 ) - >- :& - 6< ( & 6< ( & & & & F - File Name:PLM-40-SPEC 2018-05-02