100W Quad Output Switching Power Supply PQ -100 series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection With power good signal output(Optional) 100% full load burn-in test Fixed switching frequency at 45KHz 2 years warranty SPECIFICATION MODEL PQ-100B PQ-100C OUTPUT NUMBER CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 5V 12V -5V -12V 5V 15V -5V -15V RATED CURRENT 10A 3.5A 0.5A 0.5A 8A 3.5A 0.5A 0.5A CURRENT RANGE 2 ~ 10A 0.5 ~ 4.5A 0 ~ 1A 0 ~ 1A 2 ~ 8A 0.5 ~ 4A 0 ~ 1A 0 ~ 1A RATED POWER 100.5W 102.5W RIPPLE & NOISE (max.) Note.2 80mVp-p 250mVp-p 80mVp-p 120mVp-p 80mVp-p 150mVp-p 80mVp-p 150mVp-p OUTPUT VOLTAGE ADJ. RANGE CH1:4.75 ~ 5.5V CH1:4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 3.0% 12% 6.0% 6.0% 2.0% 6.0% 6.0% 6.0% LINE REGULATION 1.0% 5.0% 1.0% 1.0% 1.0% 3.0% 1.0% 1.0% LOAD REGULATION 2.0% 5.0% 1.0% 1.0% 1.0% 5.0% 1.0% 1.0% SETUP, RISE TIME 1200ms, 50ms at full load HOLD UP TIME (Typ.) 80ms at full load VOLTAGE RANGE 100 ~ 264VAC 141 ~370VDC (90 ~ 100VAC 90% load max.) FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY(Typ.) 72% 74% INPUT AC CURRENT (Typ.) 3A/115VAC 1.5A/230VAC INRUSH CURRENT (Typ.) COLD START 50A LEAKAGE CURRENT <1mA /240VAC 105% ~ 135% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION CH1: 5.75 ~ 6.75VDC OVER VOLTAGE Protection type : Hiccup mode, recovers automatically after fault condition is removed 1ms FUNCTION POWER GOOD -10 ~ +50 ,60 with cooling fan (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMC (Note 4) Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC EMISSION EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A MTBF 258.6K hrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION 177.8*107.95*46mm (L*W*H) PACKING 0.56Kg 24pcs/14.5Kg/1.19CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on 100W Quad Output Switching Power Supply PQ -100 series Features : Universal AC input / Full range Protections:Short circuit/Over load/Over voltage Cooling by free air convection With power good signal output(Optional) 100% full load burn-in test Fixed switching frequency at 45KHz 2 years warranty SPECIFICATION MODEL PQ-100D PQ-100E OUTPUT NUMBER CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 5V 12V 24V -12V 5V 12V 15V 24V RATED CURRENT 5A 2A 2A 0.5A 8A 3A 0.6A 0.6A CURRENT RANGE 2 ~ 5A 0.5 ~ 4.5A 0.4 ~ 2A 0 ~ 1A 2 ~ 8A 0.5 ~ 3A 0 ~ 1A 0 ~ 1A RATED POWER 103W 99.4W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 180mVp-p 120mVp-p 80mVp-p 120mVp-p 150mVp-p 120mVp-p OUTPUT VOLTAGE ADJ. RANGE CH1:4.75 ~ 5.5V CH1:4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 6.0% 10% 6.0% 2.0% 6.0% 6.0% 6.0% LINE REGULATION 1.0% 3.0% 1.0% 1.0% 1.0% 3.0% 1.0% 1.0% LOAD REGULATION 1.0% 5.0% 5.0% 1.0% 1.0% 5.0% 1.0% 1.0% SETUP, RISE TIME 1200ms, 50ms at full load HOLD TIME (Typ.) 80ms at full load VOLTAGE RANGE 100 ~ 264VAC 141 ~370VDC (90 ~ 100VAC 90% load max.) FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 77% 74% INPUT AC CURRENT (Typ.) 3A/115VAC 1.5A/230VAC INRUSH CURRENT (Typ.) COLD START 50A LEAKAGE CURRENT <1mA /240VAC 105% ~ 135% rated output power OVER LOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION CH1: 5.75 ~ 6.75VDC OVER VOLTAGE Protection type : Hiccup mode, recovers automatically after fault condition is removed 1ms FUNCTION POWER GOOD WORKING TEMP. -10 ~ +50 ,60 with cooling fan (Refer toDerating Curv) 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMC (Note 4) Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC EMISSION EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A MTBF 258.6K hrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION 177.8*107.95*46mm (L*W*H) 0.56Kg 24pcs/14.5Kg/1.19CUFT PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on