35W Single Output with Battery Charger(UPS Function) PSC-35 series Bauart gepruft Sicherheit egelma ge od os be wac g www.tuv.com ID 2000000000 UL62368-1 BS EN/EN62368-1 TPTC004 IEC62368-1 %& % ( ) * + , -& . &/ . 0 + 1 1 2 + 1 3445 1 + - -6 7 . + 849 : 9 + 1 < . + - 11 =:5> 4 4 1 . 2 + > 1 - + , % & %0 * File Name:PSC-35-SPEC 2021-06-2135W Single Output with Battery Charger(UPS Function) PSC-35 series - / . / . > > / / / / SPECIFICATION MODEL PSC-35A PSC-35B OUTPUT NUMBER CH1 CH2 CH1 CH2 DC VOLTAGE 13.8V 13.8V 27.6V 27.6V RATED CURRENT 1.7A 0.9A 0.85A 0.45A CURRENT RANGE 0 ~ 2.6A -------- 0 ~ 1.3A -------- RATED POWER 35.88W 35.88W RIPPLE & NOISE (max.) Note.2 120mVp-p -------- 240mVp-p -------- OUTPUT VOLTAGE ADJ. RANGE CH1: 12 ~ 15V CH1: 24 ~ 29V VOLTAGE TOLERANCE Note.3 1.0% -------- 1.0% -------- LINE REGULATION 0.5% -------- 0.5% -------- LOAD REGULATION 0.5% -------- 0.5% -------- SETUP, RISE TIME Note.4 800ms, 50ms/230VAC 1600ms, 50ms/115VAC at full load HOLD UP TIME (Typ.) 50ms/230VAC 10ms/115VAC at full load VOLTAGE RANGE 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz 86% EFFICIENCY (Typ.) 84% INPUT AC CURRENT (Typ.) 0.75A/115VAC 0.5A/230VAC INRUSH CURRENT (Typ.) COLD START 20A/115VAC 40A/230VAC LEAKAGE CURRENT <1mA / 240VAC 105 ~ 150% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION CH1:14.49 ~ 19.5V CH1:28.98 ~ 39.5V OVER VOLTAGE Protection type : Shut down O/P Voltage, repower on to recover BATTERY CUT OFF 100.5V 201V TTL open collector output, ON : AC OK OFF : AC Fail Ice : max. 30mA 50VDC AC OK FUNCTION TTL open collector output, ON : Battery Low OFF : Battery OK Ice : max. 30mA 50VDC BATTERY LOW Battery low voltage : < 11V Battery low voltage : < 22V -30 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY STORAGE TEMP., HUMIDITY -20 ~ +85, 10 ~ 95% RH ENVIRONMENT TEMP. COEFFICIENT 0.03%/ (0~50) on CH1 output VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & EMC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH (Note 4) Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 EMC EMISSION EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, light industry level, criteria A, EAC TP TC 020 MTBF 658.4 K hrs min. MIL-HDBK-217F (25) PCB:84.6*50.8*24mm (L*W*H) Enclosed type:86.4*59.6*30mm (L*W*H) OTHERS DIMENSION PACKING PCB:0.092Kg 90pcs/9.28Kg/0.97CUFT Enclosed type: 0.145Kg 100pcs/15.5Kg/1.03CUFT 3 A 49 . - 1 + NOTE B C 4)D( 1 + + 3 % 4 3 1 C 1 . * 1 1 A 1 - D D 3.D + : D D 3 1 + 1 E 1 E + 1 ) 1 ) . 1 F )< 1 G (as available on