1000W with PFC and Parallel Function PSPA-1000 series Bauart gepruft Sicherheit egelma ge od os be wac g www.tuv.com ID 2000000000 1 ) 2 2 3 ) 2 4 5) 5) ) 5) 3 2 * * <2 67/ 8 5 3 59 522 3 : %& ( ) ) * %( +( , - * . * , % /0 * = ) * . . 59 522 . ) > * < ) 6 %( :( % ( +(8 < File Name:PSPA-1000-SPEC 2018-03-021000W with PFC and Parallel Function PSPA-1000 series SPECIFICATION MODEL PSPA-1000-12 PSPA-1000-15 PSPA-1000-24 PSPA-1000-48 DC VOLTAGE 12V 15V 24V 48V RATED CURRENT 80A 64A 42A 21A CURRENT RANGE 0 ~ 80A 0 ~ 64A 0 ~ 42A 0 ~ 21A RATED POWER 960W 960W 1008W 1008W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 200mVp-p 250mVp-p OUTPUT VOLTAGE ADJ. RANGE 11 ~ 14V 14 ~ 17V 22 ~ 28V 46 ~ 56V VOLTAGE TOLERANCE Note.3 2.0% 1.5% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 2.0% 1.5% 0.5% 0.5% SETUP, RISE TIME 1000ms,50ms/115VAC 1000ms,50ms/230VAC HOLD UP TIME (Typ.) 16ms at full load VOLTAGE RANGE Note.4 90 ~ 264VAC(300VAC for 5 sec.) 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) 0.95/230VAC 0.99/115VAC at full load INPUT EFFICIENCY(Typ.) 92% 93% 93.5% 94% AC CURRENT (Typ.) 8.5A/115VAC 5A/230VAC INRUSH CURRENT (Typ.) 20A/115VAC 40A/230VAC LEAKAGE CURRENT <0.5mA/240VAC 105 ~ 135% rated output power OVERLOAD Protection type : Constant current limiting, recovers automatically after fault condition is removed 14.5 ~ 16.5V 18.2 ~ 20.6V 29 ~ 33V 58 ~ 65V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Up to 4000W or (3+1) units. Please refer to the Function Manual. CURRENT SHARING REMOTE ON-OFF CONTROL Power ON : short Power OFF : open. Please refer to the Function Manual. FUNCTION REMOTE SENSE Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual. The TTL signal out, PSU turn on = 2.4 ~ 5V PSU turn off = 0 ~ 0.4V. Please refer to the Function Manual. POK SIGNAL WORKING TEMP. -20 ~ +70 (Refer toDerating Curv) 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL62368-1, TUV EN62368-1, EAC TP TC 004 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Parameter Standard Test Level / Note Conducted EN55032 (CISPR32) / EN55011 (CISPR11) Class B EMC EMISSION Radiated EN55032 (CISPR32) / EN55011 (CISPR11) Class B Harmonic Current EN61000-3-2 Class A Voltage Flicker EN61000-3-3 ----- SAFETY & EN55024, EN61000-6-2 EMC (Note 5) Parameter Standard Test Level / Note ESD EN61000-4-2 Level 3, 8KV air Level 2, 4KV contact Radiated EN61000-4-3 Level 3 EFT / Burst EN61000-4-4 Level 3 EMC IMMUNITY Surge EN61000-4-5 Level 4, 2KV/Line-Line 4KV/Line-Earth Conducted EN61000-4-6 Level 3 Magnetic Field EN61000-4-8 Level 4 >95% dip 0.5 periods, 30% dip 25 periods, Voltage Dips and Interruptions EN61000-4-11 >95% interruptions 250 periods MTBF 274.3K hrs min. Telcordia SR-332 (Bellcore) 94.4K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 170*120*93mm (L*W*H) PACKING 1.93Kg 8pcs/16.4Kg/1.53CUFT 95 %7 ( . %: * NOTE % < % AB * * %C 0 7 4 . * ) , ) : * = D * > * 7& E7& , = * D ) 2 D . FD G H 6 ) * 4 8 & * 7 : : % 6&: 8 File Name:PSPA-1000-SPEC 2018-03-02