60W PWM Output LED Driver PW M -60 series 2 (for DA2-Type only) (for DA-Type only) IS 15885(Part 2/Sec13) THOMAS SAMUEL THOMAS SAMUEL I P 6 7 R-41027766 File Name:PWM-60-SPEC 2021-04-0160W PWM Output LED Driver PWM -60 s e ri es SPECIFICATION MODEL PWM-60-12 PWM-60-24 PWM-60-36 PWM-60-48 DC VOLTAGE 12V 24V 36V 48V RATED CURRENT 5A 2.5A 1.67A 1.25A RATED POWER 60W 60W 60.12W 60W OUTPUT DIMMING RANGE 0 ~ 100% PWM FREQUENCY (Typ.) 1.47kHz for Blank/DA-Type, 2.5kHz for DA2-Type Note.2 SSEETTUUPP, R, RIISSE TE TIIMMEE 500ms, 80ms/ 115AC or 230VAC Note.9 HOLD UP TIME (Typ.) 16ms/115VAC or 230VAC 90 ~ 305VAC 127 ~ 431VDC VOLTAGE RANGE Note.3 (Please refer toSTATIC CHARACTERISTI section) FREQUENCY RANGE 47 ~ 63Hz PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC full load POWER FACTOR (Typ.) (Please refer toPOWER FACTOR (PF) CHARACTERISTI section) THD< 20%( load60%/115VAC, 230VAC load75%/277VAC) TOTAL HARMONIC DISTORTION (Please refer to TOTAL HARMONIC DISTORTION section) EFFICIENCY (Typ.) 86% 89% 90% 90% INPUT AC CURRENT (Typ.) 0.8A / 115VAC 0.4A / 230VAC 0.32A / 277VAC INRUSH CURRENT (Typ.) COLD START 50A(twidth=270s measured at 50% Ipeak) at 230VAC Per NEMA 410 MAX. NO. of PSUs on 16A 9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC CIRCUIT BREAKER LEAKAGE CURRENT <0.25mA / 277VAC <0.5W 108 ~ 130% rated output power OVERLOAD Hiccup mode, recovers automatically after fault condition is removed Shut down o/p voltage, re-power on to recover(except for DA2-type) SHORT CIRCUIT Hiccup mode,recovers automatically after fauit condition is removed (only for DA2-type) PROTECTION 15 ~ 17V 28 ~ 34V 41 ~ 46V 54 ~ 60V OVER VOLTAGE Shut down o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover OVER TEMPERATURE WORKING TEMP. Tcase=-40 ~ +85 (Please refer to OUTPUT LOAD vs TEMPERATURE section) MAX. CASE TEMP. Tcase=+85 20 ~ 95% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80, 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750( type HL )( except for DA-Type), UL879( for 12V,24V Blank Type only), CSA C22.2 No. 250.13-12 ENEC EN61347-1, EN61347-2-13 independent, EN62384, IP67,BIS IS15885(for 12,24,48 Blank Type only), EAC TP TC 004, GB19510.1,GB19510.14 SAFETY STANDARDS Note.5 approved Design refer to EN60335-1 According to EN61347-2-13 appendix J suitable for emergency installations DALI STANDARDS IEC62386-101, 102, 207,251 for DA/DA2-Type only,Device type 6(DT6) WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-DA:1.5KVAC O/P-DA:1.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH EMC EMC EMISSION Note.6 Compliance to EN55015, EN61000-3-2 Class C ( load60%) EN61000-3-3,GB17743 and GB17625.1,EAC TP TC 020 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11 EN61547, light industry level (surge immunity Line-Line 2KV),EAC TP TC 020 MTBF 996K hrs min. Telcordia SR-332 (Bellcore) 271.03K hrs min. MIL-HDBK-217F (25) 150*53*35mm (L*W*H) OTHERS DIMENSION PACKING 0.49Kg 30pcs/15.7Kg/1.0CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25of ambient temperature. NOTE 2. De-rating may be needed under low input voltages. Please refer to STATIC CHARACTERISTIC sections for details. 3. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time. 4. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 5. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75or less. 6. Please refer to the warranty statement on MEAN WELL s website at