90W Constant Voltage PWM Output LED Driver PW M -90 series Users Manual 2 (for DA2-Type only) (for DA Type only) IS 15885(Part 2/Sec13) THOMAS SAMUEL THOMAS SAMUEL I P 6 7 R-41027766 File Name:PWM-90-SPEC 2021-09-1790W PWM Output LED Driver PWM -90 s e ri e s SPECIFICATION MODEL PWM-90-12 PWM-90-24 PWM-90-36 PWM-90-48 DC VOLTAGE 12V 24V 36V 48V RATED CURRENT 7.5A 3.75A 2.5A 1.88A RATED POWER 90W 90W 90W 90.24W DIMMING RANGE 0 ~ 100% OUTPUT PWM FREQUENCY (Typ.) 1.47kHz for Blank/DA-Type, 2.5kHz for DA2-Type Note.2 SETUP, RISE TIME 500ms, 80ms/ 115VAC or 230VAC Note.9 HOLD UP TIME (Typ.) 16ms/115VAC or 230VAC 90 ~ 305VAC 127 ~ 431VDC VOLTAGE RANGE Note.3 (Please refer toSTATIC CHARACTERISTI section) FREQUENCY RANGE 47 ~ 63Hz PF>0.98/115VAC, PF>0.96/230VAC, PF>0.92/277VAC full load POWER FACTOR (Typ.) (Please refer toPOWER FACTOR (PF) CHARACTERISTI section) THD< 20%( load60%/115VAC, 230VAC load75%/277VAC) TOTAL HARMONIC DISTORTION (Please refer to TOTAL HARMONIC DISTORTION section) EFFICIENCY (Typ.) 88% 90.5% 90.5% 90.5% INPUT AC CURRENT (Typ.) 0.95A / 115VAC 0.5A / 230VAC 0.4A / 277VAC INRUSH CURRENT (Typ.) COLD START 60A(twidth=550 s measured at 50% Ipeak) at 230VAC Per NEMA 410 MAX. NO. of PSUs on 16A 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC CIRCUIT BREAKER LEAKAGE CURRENT <0.25mA / 277VAC <0.5W 108 ~ 130% rated output power OVERLOAD Hiccup mode, recovers automatically after fault condition is removed Shut down o/p voltage, re-power on to recover(except for DA2-type) SHORT CIRCUIT Hiccup mode,recovers automatically after fault condition is removed (only for DA2-type) PROTECTION 15 ~ 17V 28 ~ 34V 41 ~ 46V 54 ~ 60V OVER VOLTAGE Shut down o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover OVER TEMPERATURE WORKING TEMP. Tcase=-40 ~ +85 (Please refer to OUTPUT LOAD vs TEMPERATURE section) MAX. CASE TEMP. Tcase=+85 WORKING HUMIDITY 20 ~ 95% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80, 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750(except for DA-Type), CSA C22.2 No. 250.13-12 ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, SAFETY STANDARDS Note.5 BS EN/EN62384, IP67,BIS IS15885(for 12,24,48 Blank Type only), EAC TP TC 004,GB19510.1, GB19510.14 approved Design refer to BS EN/EN60335-1 According to BS EN/EN61347 -2 -13 appendix J suitable for emergency installations DALI STANDARDS IEC62386-101, 102, 207,251 for DA/DA2-Type only,Device type 6(DT6) SAFETY & WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-DA:1.5KVAC O/P-DA:1.5KVAC EMC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C ( load60%) BS EN/EN61000-3-3,GB17743 and EMC EMISSION Note.6 GB17625.1,EAC TP TC 020 Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11 BS EN/EN61547, light industry level (surge immunity Line-Line 2KV), EMC IMMUNITY EAC TP TC 020 MTBF 902.4K hrs min. Telcordia SR-332 (Bellcore) 224.2K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 171*63*37.5mm (L*W*H) PACKING 0.77Kg 18pcs/14.9Kg/0.97CUFT NOTE ,