300W Reliable Green Medical Power Supply RPS-300 series Users Manual 89 , , 8 , , + + - *9 :**5 8 , , 89:89 , , 8 , , ( > > 6 5 + 3& 1 56 7 G *9 :**5 8 , , 8 : 89:89 , , 5 + & + 2 9 A 69 8 81 / ) 2 ,&) 2 B 2 C : 6+ : 6+ + : 6+ . D E ( F %& ()* + + ,&) (- . / 0 1 . 1 / , 2 3&456 7 85 89:89 ,,2 / < = 3 7 Type 6 + / / . 8 . / File Name:RPS-300-SPEC 2022-01-04300W Reliable Green Medical Power Supply RPS-300 series SPECIFICATION MODEL RPS-300-12 RPS-300-15 RPS-300-24 RPS-300-27 RPS-300-48 DC VOLTAGE 24V 48V 12V 15V 27V 25A 12.5A RATED CURRENT (20.5CFM) 20A 11.12A 6.25A 0 ~ 16.67A Convection 0 ~ 7.4A 0 ~ 13.33A 0 ~ 8.33A 0 ~ 4.17A CURRENT 0 ~ 25A 0 ~ 12.5A 0 ~ 11.12A 20.5CFM 0 ~ 20A 0 ~ 6.25A 200W 200W 200W Convection 200W 200.2W RATED POWER 300W 300W 20.5CFM 300W 300W 300W OUTPUT RIPPLE & NOISE (max.) Note.2 120mVp-p 150mVp-p 200mVp-p 250mVp-p 120mVp-p VOLTAGE ADJ. RANGE (main output ) 22.8 ~ 25.2V 25.65 ~ 28.35V 45.6 ~ 50.4V 11.4 ~ 12.6V 14.25 ~ 15.75V VOLTAGE TOLERANCE Note.3 3.0% 2.0% 2.0% 3.0% 2.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 2500ms, 30ms/230VAC 3000ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 13ms/230VAC/115VAC at full load VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.93/230VAC PF>0.98/115VAC at full load EFFICIENCY (Typ.) 90% 90% 92.5% 93% 93% INPUT AC CURRENT (Typ.) 3.5A/115VAC 1.8A/230VAC INRUSH CURRENT (Typ.) COLD START 35A/115VAC 70A/230VAC PCB Type: Earth leakage current <150A / 264VAC, Touch current <70 A/264VAC LEAKAGE CURRENT(max.) Note.5 Enclosed Type: Earth leakage current <200A / 264VAC, Touch current <70 A/264VAC 105 ~ 135% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed 13.5 ~ 15V 16.2 ~ 18.5V 26 ~ 30V 29.5 ~ 33.5V 52 ~ 59.5V OVER VOLTAGE PROTECTION Protection type : Shut down o/p voltage, re-power on to recover Protection type : (TSW1)Shut down o/p voltage, recovers automatically after temperature goes down OVER TEMPERATURE Protection type : (TSW2)Shut down o/p voltage, re-power on to recover 5V STANDBY 5Vsb : 5V 0.6A without fan, 1A with fan 20.5CFM tolerance 2%, ripple : 150mVp-p(max.) FAN SUPPLY 12V 0.5A for driving a fan Tolerance -15% ~ +10% at main output 20% rated current (20.5CFM) FUNCTION Power on: PS-ON =H or > 2 ~ 5 Power off: PS-ON =Lo or < 0 ~ 0.5 PS-ON INPUT SIGNAL 500ms>PG>10ms The TTL signal goes high with 10ms to 500ms delay after power set up POWER GOOD / POWER FAIL The TTL signal goes low at least 1ms before Vo below 90% of rated value -30 ~ +70 (Refer toDerating Curv) WORKING TEMP. WORKING HUMIDITY 20 ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH non-condensing ENVIRONMENT TEMP. COEFFICIENT0.03%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes OPERATING ALTITUDE Note.6 2000 meters File Name:RPS-300-SPEC 2022-01-04