30W Reliable Green Medical Power Supply RPS-30 series Users Manual + + 4/4 3 ()*( % % + % , -* . //0 %% %& % % Suitable for BF application with appropriate system consideration % Cooling by free air convection EMI class B for class configuration No load power consumption<0.1W Extremely low leakage current Protections: Short circuit / Overload / Over voltage 1 , 2 5K hours 3 Description RPS-30 is a 30W highly reliable green PCB type medical power supply with a high power density on the 3 by 2 footprint. It accepts 80~264VAC input and offers various output voltages between 3.3V and 48V. The working efficiency is up to 92% and the extremely low no load power consumption is down below 0.1W. RPS-30 is able to be used for Class(no FG) system design. The extremely low leakage current is less than 80 A. In addition, it conforms to international medical regulations (2*MOPP) and EMC EN55011, perfectly fitting all kinds of BF rated patient contact medical system equipment.a File Name:RPS-30-SPEC 2021-09-1530W Reliable Green Medical Power Supply RPS-30 series SPECIFICATION ORDER NO. RPS--30 3.3 RPS--30 5 RPS--30 75. RPS--30 12 RPS--30 15 RPS--30 24 RPS--30 48 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 48V RATED CURRENT 6A 6A 4A 2.5A 2A 1.25A 0.625A CURRENT RANGE 0 ~ 6.6A 0 ~ 6.6A 0 ~ 4.4A 0 ~ 2.75A 0 ~ 2.2A 0 ~ 1.375A 0 ~ 0.687A RATED POWER 19.8W 30W 30W 30W 30W 30W 30W OUTPUT PEAK LOAD(10sec.) Note.2 21.8W 33W 33W 33W 33W 33W 33W RIPPLE & NOISE (max.) Note.3 80mVp-p 80mVp-p 80mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 3.1~3.6V 47.~.V55 7.12~8.3V 11.4~13.2V 13.5~16.5V 22.8~27.6V 45.6~52.8V VOLTAGE ADJ.RANGE VOLTAGE TOLERANCE 2.0% 2.0% 2.0% 2.0% 2.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 200ms, 30ms / 230VAC 200ms, 30ms / 115VAC at full load HOLD UP TIME (Typ.) 30ms / 230VAC 16ms / 115VAC at full load VOLTAGE RANGE Note.5 80 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY (Typ.) 80% 82% 84% 88% 89% 89.5% 92% AC CURRENT (Typ.) 1A / 115VAC 0.5A / 230VAC INRUSH CURRENT (Typ.) OLD STAR 30A/115VAC 60A/230VAC LEAKAGE CURRENT(max.) Note.6 Touch current< 80 A/264VAC 115 ~ 150% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION 3.8~5V 5.7~6.8V 8.6~11.3V 13.8~16.2V 17.2~20.3V 28.4~32.4V 55.2~64.8V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover WORKING TEMP. -30 ~ +70 (Refer toDerating Curv) WORKING HUMIDITY 20% ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing ENVIRONMENT TEMP. COEFFICIENT 0.03% /(0 ~ 50 ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes OPERATING ALTITUDE Note.7 4000 meters IEC60601-1, TUV BS EN/EN60601-1, EAC TP TC 004, UL ANSI / AAMI ES60601-1 (3.1 version), SAFETY STANDARDS CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 approved Design refer to BS EN/EN60335-1 ISOLATION LEVEL Primary-Secondary: 2xMOPP WITHSTAND VOLTAGE I/P-O/P: 4KVAC I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH ISOLATION RESISTANCE Parameter Standard Test Level / Note Conducted emission BS EN/EN55011 (CISPR11) Class B EMC EMISSION Radiated emission BS EN/EN55011 (CISPR11) Class B SAFETY & Harmonic current BS EN/EN61000-3-2 Class A Voltage flicker BS EN/EN61000-3-3 ----- EMC (Note. 8) BS EN/EN60601-1-2 Parameter Standard Test Level / Note ESD BS EN/EN61000-4-2 Level 4, 15KV air Level 4, 8KV contact Level 3, 10V/m( 80MHz~2.7GHz ) RF field susceptibility BS EN/EN61000-4-3 Table 9, 9~28V/m( 385MHz~5.78GHz ) EFT bursts BS EN/EN61000-4-4 Level 3, 2KV EMC IMMUNITY Surge susceptibility BS EN/EN61000-4-5 Level 4, 2KV/Line-Line Conducted susceptibility BS EN/EN61000-4-6 Level 3, 10V Magnetic field immunity BS EN/EN61000-4-8 Level 4, 30A/m 100% dip 1 periods, 30% dip 25 periods, Voltage dip, interruption BS EN/EN61000-4-11 100% interruptions 250 periods 628.7Khrs min. MIL-HDBK-217(25) MTBF DIMENSION (L*W*H) 76.2*50.8*24mm or 3 * 2 *0.945 inch OTHERS 0.09Kg 120pcs/11.8Kg/0.94CUFT PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1 f & 47 f parallel capacitor. 4. Tolerance : includes set up tolerance, line regulation and load regulation. NOTE 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. Touch current was measured from primary input to DC output. 7. 4& 5 , 67 & , , 7 & , , & & & * - 7 , 06 8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on