100W Railway Single Output DC-DC Converter RSD-100 series 2 2 . * * , >+ < 6 < 6 6 , < 9 6 9< , 6 ( . , A * 07 , , B2 * C . 0 * SPECIFICATION MODEL RSD-100B-5 RSD-100B-12 RSD-100B-24 RSD-100C-5 RSD-100C-12 RSD-100C-24 RSD-100D-5 RSD-100D-12 RSD-100D-24 DC VOLTAGE 5V 12V 24V 5V 12V 24V 5V 12V 24V RATED CURRENT 20A 8.4A 4.2A 20A 8.4A 4.2A 20A 8.4A 4.2A CURRENT RANGE 0 ~ 20A 0 ~ 8.4A 0 ~ 4.2A 0 ~ 20A 0 ~ 8.4A 0 ~ 4.2A 0 ~ 20A 0 ~ 8.4A 0 ~ 4.2A RATED POWER 100W 100.8W 100.8W 100W 100.8W 100.8W 100W 100.8W 100.8W RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 150mVp-p 100mVp-p 120mVp-p 150mVp-p 100mVp-p 120mVp-p 150mVp-p OUTPUT VOLTAGE TOLERANCE Note.3 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% LINE REGULATION 0.5% 0.3% 0.2% 0.5% 0.3% 0.2% 0.5% 0.2% 0.2% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 800ms, 50ms at full load HOLD UP TIME (Typ.) B/C- type comply with S1 level full load, comply with S2 level 70% load D-type comply with S2 level full load CONTINUOUS 16.8 ~ 31.2VDC 33.6 ~ 62.4VDC 67.2 ~ 143VDC VOLTAGE RANGE 14.4 ~ 33.6VDC 28.8 ~ 67.2VDC 57.6 ~ 154VDC 1 SEC. EFFICIENCY (Typ.) 88% 89% 89% 89% 91% 91% 89.5% 91% 90% INPUT DC CURRENT (Typ.) 4.8A/24V 4.8A/24V 4.8A/24V 2.4A/48V 2.4A/48V 2.4A/48V 1.2A/110V 1.2A/110V 1.2A/110V INRUSH CURRENT (Typ.) 30A/48VDC 30A/110VDC 30A/24VDC 105 ~ 135% rated output power OVERLOAD Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTION 5.75 ~ 7V 13.8 ~ 16.2V 27.6 ~ 32.4V 5.75 ~ 7V 13.8 ~ 16.2V 27.6 ~ 32.4V 5.75 ~ 7V 13.8 ~ 16.2V 27.6 ~ 32.4V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover -40 ~ +55(no derating) +70 60% load by free air convection +70 no derating with external base plate, TX class compliance WORKING TEMP. 5 ~ 95% RH non-condensing WORKING HUMIDITY ENVIRONMENT -40 ~ +85, 5 ~ 95% RH STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes Mounting : compliance to IEC61373 SAFETY STANDARDS Meet IEC60950-1(LVD) WITHSTAND VOLTAGE I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC EMC EMISSION Compliance to EN55022 (CISPR22) Conduction Emission: Class A, Radiation Emission: Class B (Note 4) EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A RAILWAY STANDARD Meet EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC EN45545-2 for fire protection MTBF 254.1K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 161*68*36mm (L*W*H) 0.6Kg 24pcs/15.4Kg/0.98CUFT PACKING NOTE % & () * + , - * .* * + & / 0 , , + * *+ + * 1 + 2 3 , + 07 407 * + + 5 + 1 . + 2 6 , + * + 2 82 9 , * : 6 + <<*** * = > , + 3 + 3 File Name:RSD-100-SPEC 2015-08-062-R1.75 100W Railway Single Output DC-DC Converter RSD-100 series Mechanical Specification Case No.999A Unit:mm 12max. 12max. 156 2.5 161 156 2.5 LED I/P O/P 1 1 2 2 3 4-R1.75 Input Terminal Pin No. Assignment : Output Terminal Pin No. Assignment : Pin No. Assignment Pin No. Assignment 1 DC INPUT V+ 1 DC OUTPUT -V 2 DC INPUT V- 2 DC OUTPUT +V 3 FG Block Diagram fosc : 130KHz RECTIFIERS EMI POWER +V I/P & FILTER SWITCHING -V FILTER FG DETECTION PWM CIRCUIT O.L.P. CONTROL O.V.P. Input Fuse There is one fuse connected in series to the positive input line, which is used to protect against abnormal surge. Fuse specifications of each model are shown as below. Type Fuse Type Reference and Rating B Time-Lag Conquer UDA-A, 10A, 250V C Time-Lag Conquer UDA-A, 5A, 250V D Time-Lag Conquer UDA-A, 3.15A, 250V File Name:RSD-100-SPEC 2015-08-06 8.2 9.5 55 25 6.5 68 36