200W Railway Single Output DC-DC Converter RSD-200 series 2 2 . * * , >+ < 6 < 6 6 , < 6 < 9 6 9< , 6 ( . , A * , , B2 * C . 0 * SPECIFICATION MODEL RSD-200B-12 RSD-200B-24 RSD-200B-48 RSD-200C-12 RSD-200C-24 RSD-200C-48 RSD-200D-12 RSD-200D-24 RSD-200D-48 DC VOLTAGE 12V 24V 48V 12V 24V 48V 12V 24V 48V RATED CURRENT 16.7A 8.4A 4.2A 16.7A 8.4A 4.2A 16.7A 8.4A 4.2A CURRENT RANGE 0 ~ 16.7A 0 ~ 8.4A 0 ~ 4.2A 0 ~ 16.7A 0 ~ 8.4A 0 ~ 4.2A 0 ~ 16.7A 0 ~ 8.4A 0 ~ 4.2A RATED POWER 200.4W 201.6W 201.6W 200.4W 201.6W 201.6W 200.4W 201.6W 201.6W RIPPLE & NOISE (max.) Note.2 120mVp-p 150mVp-p 180mVp-p 120mVp-p 150mVp-p 180mVp-p 120mVp-p 150mVp-p 180mVp-p OUTPUT VOLTAGE TOLERANCE Note.3 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% LINE REGULATION 0.2% 0.2% 0.5% 0.2% 0.2% 0.5% 0.2% 0.2% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 800ms, 50ms at full load HOLD UP TIME (Typ.) B/C- type comply with S1 level full load, comply with S2 level 70% load D-type comply with S2 level full load 16.8 ~ 31.2VDC 33.6 ~ 62.4VDC 67.2 ~ 143VDC CONTINUOUS VOLTAGE RANGE 1 SEC. 14.4 ~ 33.6VDC 28.8 ~ 67.2VDC 57.6 ~ 154VDC INPUT EFFICIENCY (Typ.) 89% 89% 89% 91% 91% 91% 91% 91% 91% 9.6A/24V 9.6A/24V 9.6A/24V 4.8A/48V 4.8A/48V 4.8A/48V 2.1A/110V 2.1A/110V 2.1A/110V DC CURRENT (Typ.) INRUSH CURRENT (Typ.) 45A/24VDC 45A/48VDC 45A/110VDC 105 ~ 135% rated output power OVERLOAD Protection type : Constant current limiting, recovers automatically after fault condition is removed 13.8 ~ 16.2V 27.6 ~ 32.4V 55.2 ~ 64.8V 13.8 ~ 16.2V 27.6 ~ 32.4V 55.2 ~ 64.8V 13.8 ~ 16.2V 27.6 ~ 32.4V 55.2 ~ 64.8V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, recovers automatically after temperature goes down OVER TEMPERATURE -40 ~ +55(no derating) +70 60% load by free air convection +70 no derating with external base plate, TX class compliance WORKING TEMP. 5 ~ 95% RH non-condensing WORKING HUMIDITY ENVIRONMENT -40 ~ +85, 5 ~ 95% RH STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes Mounting : compliance to IEC61373 Meet IEC60950-1(LVD) SAFETY STANDARDS WITHSTAND VOLTAGE I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC EMC EMISSION Compliance to EN55022 (CISPR22) Conduction Emission: Class A, Radiation Emission: Class B (Note 4) EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A RAILWAY STANDARD Meet EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC EN45545-2 for fire protection MTBF 218.2K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 191*86*40mm (L*W*H) 0.94Kg 12pcs/12.3Kg/0.8CUFT PACKING NOTE % & () * + , - * .* * + & / 0 , , + * *+ + * 1 + 2 3 , + 07 407 * + + 5 + 1 . + 2 6 , + * + 2 82 9 , * : 6 + <<*** * = > , + 3 + 3 File Name:RSD-200-SPEC 2015-08-062-R2.1 200W Railway Single Output DC-DC Converter RSD-200 series Mechanical Specification Case No.203A Unit:mm 10max. 15max. 183 4 191 183 4 LED I/P O/P 1 1 2 2 3 4-R2.1 Input Terminal Pin No. Assignment : Output Terminal Pin No. Assignment : Pin No. Assignment Pin No. Assignment 1 DC INPUT V+ 1 DC OUTPUT -V 2 DC INPUT V- 2 DC OUTPUT +V 3 FG Block Diagram fosc : 130KHz RECTIFIERS EMI POWER +V I/P & FILTER SWITCHING -V FILTER FG DETECTION O.L.P. PWM CIRCUIT CONTROL O.T.P. O.V.P. Input Fuse There are one or two fuses connected in series to the positive input line, which are used to protect against abnormal surge. Fuse specifications of each model are shown as below. Type Fuse Type Reference and Rating B Time-Lag 2*Conquer UDA-A, 10A, 250V C Time-Lag Conquer UDA-A, 10A, 250V D Time-Lag Conquer UDA-A, 5A, 250V File Name:RSD-200-SPEC 2015-08-06 9.5 8.2 10 13 28 72 7 40 86