500W Enclosed Type Reliable Railway DC-DC Converter RSD-500 series IEC62368-1 UL62368-1 AS/NZS62368-1 TPTC004 6 - * 9 : %& < ( = ) * + , + , + > ,, , + - + - ./ -+, 01 2 , 0 3 2 4 5 1* 3 = + 73& 5537/+5537 783 /+783 / < 9 / 57/ &/ 8 / 7/ /3/ / / &/ 3 = < %& A ./ -+, 3 - 3 , 0 + + &/ 2 - 06 73& 5537/ 5537 783 / 783 / 2 1 * File Name:RSD-500-SPEC 2020-06-01500W Enclosed Type Reliable Railway DC-DC Converter RSD-500 series SPECIFICATION MODEL RSD-500B-12 RSD-500B-24 RSD-500B-48 RSD-500C-12 RSD-500C-24 RSD-500C-48 RSD-500D-12 RSD-500D-24 RSD-500D-48 DC VOLTAGE 12V 24V 48V 12V 24V 48V 12V 24V 48V RATED CURRENT 35A 17.5A 8.8A 35A 19.2A 9.6A 35A 20.8A 10.4A CURRENT RANGE 0 ~ 35A 0 ~ 17.5A 0 ~ 8.8A 0 ~ 35A 0 ~ 19.2A 0 ~ 9.6A 0 ~ 35A 0 ~ 20.8A 0 ~ 10.4A RATED POWER 420W 420W 422.4W 420W 460.8W 460.8W 420W 499.2W 499.2W OUTPUT RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 150mVp-p 100mVp-p 120mVp-p 150mVp-p 100mVp-p 120mVp-p 150mVp-p VOLTAGE ADJ. RANGE 12 ~ 14V 24 ~ 28V 48~ 56V 12 ~ 14V 24 ~ 28V 48~ 56V 12 ~ 14V 24 ~ 28V 48~ 56V VOLTAGE TOLERANCE Note.3 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 500ms, 60ms HOLD UP TIME (Typ.) Please refer to page 4 hold up time (Load de-rating curve ) VOLTAGE CONTINUOUS 16.8 ~ 33.6Vdc 33.6 ~ 67.2Vdc 67.2 ~ 154Vdc RANGE 1s 14.4 ~ 16.8Vdc 28.8 ~ 33.6Vdc 57.6 ~ 67.2Vdc Note.4 EFFICIENCY (Typ.) 92% 92% 92% 93% 93% 93% 93% 93% 93% INPUT DC CURRENT (Typ.) 21.5A 24Vdc 11A 48Vdc 5A 110Vdc INRUSH CURRENT (Typ.) 30A INTERRUPTION OF EN50155:2017-B/C/D type comply with S1 level (3ms) full load VOLTAGE SUPPLY B/C type comply with S2 level (10ms) 70% load, D- type comply with S2 level (10ms) full load OVERLOAD Constant current limiting 105~135% rated output power with auto-recovery 14.4 ~ 17.5V 28.8 ~ 35V 57.6 ~ 65V 14.4 ~ 17.5V 28.8 ~ 35V 57.6 ~ 65V 14.4 ~ 17.5V 28.8 ~ 35V 57.6 ~ 65V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover PROTECTION Shut down o/p voltage, re-power on to recover OVER TEMPERATURE REVERSE POLARITY By internal, MOSFET, no damage, recovers automatically after fault condition is removed 24Vin :Power ON16.8V , 48Vin :Power ON33.6V , 110Vin :Power ON67.2V , UNDER VOLTAGE LOCKOUT OFF16.5V O3FF3V O6FF5V -40 ~ +80 (Refer toDerating Curv) WORKING TEMP. 5 ~ 95% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 5 ~ 95% RH non-condensing TEMP. COEFFICIENT 0.03%/ (0 ~ 55) Component:10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes Mounting: Compliance to IEC61373 VIBRATION OPERATING ALTITUDE Note.5 5000 meters / OVC SAFETY STANDARDS UL62368-1, IEC 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved WITHSTAND VOLTAGE I/P-O/P:4KVdc I/P-FG:2.5KVdc O/P-FG:2.5KVdc ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500Vdc / 25/ 70% RH Parameter Standard Test Level / Note Conducted EN55032 (CISRP32) Class A EN55032 (CISRP32) EMC EMISSION Radiated Class B ----- Voltage Flicker EN61000-3-3 SAFETY & Harmonic Current ----- ----- EMC EN55035 (Note 6 ) Parameter Standard Test Level / Note ESD EN61000-4-2 Level 3, 8KV air Level 3, 6KV contact criteria A Level 3, 10V/m criteria A Radiated EN61000-4-3 EMC IMMUNITY EFT / Burst EN61000-4-4 Level 3, 2KV criteria A Surge EN61000-4-5 Level 3, 1KV/Line-Line Level 3, 2KV/Line-Line-FG criteria A Conducted EN61000-4-6 Level 3, 10V criteria A Magnetic Field EN61000-4-8 Level 4, 30A/m criteria A RAILWAY STANDARD Compliance to EN45545-2 for fire protection EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC MTBF 277.9K hrs min. Telcordia SR-332 (Bellcore) 99.1K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 237*100*41mm (L*W*H) PACKING 1.45Kg 10pcs/15.5Kg/0.8CUFT 3 B ,= 06 / &/ / 2 3 3 1 C A>D E 3 C 8 3 53 = 3 3 3 ) < 3 3 = 53 + + 07 23 NOTE 73 = 9 A 3 : A F A- 3G 0 ++ 3 3 2 File Name:RSD-500-SPEC 2020-06-01