60W Reliable Railway DC-DC Converter RSD-60 series File Name:RSD-60-SPEC 2017-02-2860W Reliable Railway DC-DC Converter RSD-60 series SPECIFICATION MODEL RSD-60G-3.3 RSD-60G-5 RSD-60G-12 RSD-60G-24 RSD-60L-3.3 RSD-60L-5 RSD-60L-12 RSD-60L-24 DC VOLTAGE 3.3V 5V 12V 24V 3.3V 5V 12V 24V RATED CURRENT 12A 12A 5A 2.5A 12A 12A 5A 2.5A CURRENT RANGE 0 ~ 12A 0 ~ 12A 0 ~ 5A 0 ~ 2.5A 0 ~ 12A 0 ~ 12A 0 ~ 5A 0 ~ 2.5A RATED POWER 39.6W 60W 60W 60W 39.6W 60W 60W 60W RIPPLE & NOISE (max.) Note.2 60mVp-p 100mVp-p 50mVp-p 50mVp-p 60mVp-p 60mVp-p 50mVp-p 50mVp-p OUTPUT VOLTAGE TOLERANCE Note.3 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% LINE REGULATION 0.5% 0.5% 0.3% 0.2% 0.5% 0.5% 0.3% 0.2% LOAD REGULATION 0.5% 0.5% 0.3% 0.2% 0.5% 0.5% 0.3% 0.2% SETUP, RISE TIME 100ms, 60ms at full load HOLD UP TIME (Typ.) G type comply with S1 level(3ms) full load,S2 level(10ms) 50% load L type comply with S2 level(10ms) full load VOLTAGE RANGE CONTINUOUS 9 ~ 36VDC 18 ~ 72VDC EFFICIENCY (Typ.) 86.5% 88% 92% 90% 88.5% 89% 93% 91.5% INPUT DC CURRENT (Typ.) 2.1A/24VDC 3A/24VDC 0.95A/48VDC 1.5A/48VDC 20A/48VDC INRUSH CURRENT (Typ.) 20A/24VDC 105 ~ 135% rated output power OVERLOAD Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTION 4.3 ~ 4.95V 5.75 ~ 7V 13.8 ~ 16.2V 27.6 ~ 32.4V 4.3 ~ 4.95V 5.75 ~ 7V 13.8 ~ 16.2V 27.6 ~ 32.4V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover -40 ~ +55 (no derating) +70 60% load by free air convection +70 (no derating with external base plate) WORKING TEMP. 5 ~ 95% RH non-condensing WORKING HUMIDITY ENVIRONMENT -40 ~ +85, 10 ~ 95% RH non-condensing STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes Mounting : compliance to IEC61373 SAFETY STANDARDS Meet IEC60950-1 (LVD) WITHSTAND VOLTAGE I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Parameter Standard Test Level / Note Conducted EN55032 Class B Radiated EN55032 Class B SAFETY & EMC EMISSION Harmonic Current EN6100-3-2 Class A EMC Voltage Flicker EN6100-3-3 ----- (Note 4) Parameter Standard Test Level / Note ESD EN61000-4-2 Level 3, 8KV air Level 3, 6KV contact Radiated Field EN61000-4-3 Level X Level 3, 2KV at power EMC IMMUNITY EFT / Burst EN61000-4-4 Level 4, 2KV at signal Surge EN61000-4-5 Level 3,1KV Line-Line, Level 3, 2KV Line-Earth Conducted EN61000-4-6 Level 3 RAILWAY STANDARD Compliance to EN45545-2 for fire protection Meet EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC MTBF 593.8K hrs min. MIL-HDBK-217F (25) DIMENSION 128*60*25mm (L*W*H) OTHERS 0.29Kg 48pcs/14.9Kg/0.76CUFT PACKING NOTE File Name:RSD-60-SPEC 2017-02-28