1500W True Sine Wave DC-AC Inverter with Solar Charger T N- 1 5 0 0 s e ri e s Features : True sine wave output (THD<3%) High surge power up to 3000W U.P.S. mode and energy saving mode (selectable) High efficiency up to 91% Power ON-OFF switch Standby saving mode can be selectable Front panel indicator for operation status Thermostatically controlled cooling fan Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input polarity reverse / Overload / AC circuit breaker Application : Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. Built-in solar / AC charger Optional monitoring software 2 years warranty 13 E SPECIFICATION MODEL TN-1500-112 TN-1500-124 TN-1500-148 TN-1500-212 TN-1500-224 TN-1500-248 RATED POWER (Typ.) 1500W MAXIMUM OUTPUT POWER 1725W for 180 sec. / 2250W for 10 sec. / surge power 3000W for 30 cycles Factory setting set at 110VAC Factory setting set at 230VAC AC VOLTAGE 100 / 110 / 115 / 120VAC selectable by setting button S.W 200 / 220 / 230 / 240VAC selectable by setting button S.W FREQUENCY 60 0.1Hz 50/60Hz selectable by setting button S.W 50 0.1%Hz 50/60Hz selectable by setting button S.W OUTPUT WAVEFORM True sine wave (THD<3%) at rated input voltage AC REGULATION (Typ.) 3.0% TRANSFER TIME t<10ms inverter by pass Load 5W will be changed to standby mode SAVING MODE (Typ.) FRONT PANEL INDICATOR Battery voltage level, output load level, saving mode, fault and operation status BAT. VOLTAGE 12V 24V 48V 12V 24V 48V VOLTAGE RANGE (Typ.)Note.1 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC DC CURRENT (Typ.) Note.5 75A 37.5A 150A 150A 75A 37.5A INPUT 18W standby saving mode NO LOAD DISSIPATION OFF MODE CURRENT DRAW 1mA EFFICIENCY (Typ.) Note.2 87% 89% 90% 88% 90% 91% BATTERY TYPES Open & sealed Lead Acid FUSE 40A*5 30A*3 30A*2 40A*5 30A*3 30A*2 BATTERY 11.3 4% 22.5 4% 45 4% 11.3 4% 22.5 4% 45 4% BAT. LOW ALARM INPUT BAT. LOW SHUTDOWN 10.5 4% 21 4% 42 4% 10.5 4% 21 4% 42 4% PROTECTION By internal fuse open REVERSE POLARITY 82 5 82 5 96 5 68 5 68 5 68 5 OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover by internal RTH3 detect on heatsink of power transistor OUTPUT SHORT Protection type : Shut down o/p voltage, re-power on to recover OUTPUT 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. PROTECTION OVER LOAD (Typ.) Protection type : Shut down o/p voltage, re-power on to recover CIRCUIT BREAKER 20A 10A GFCI PROCTECTION Optional (Only type F) None WORKING TEMP. Note.3 0 ~ +40 100% load 60 50% load 20% ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT o -30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH STORAGE TEMP., HUMIDITY VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes UL458 (only forGFC receptacles-Type F ) EN60950-1 SAFETY STANDARDS Bat I/P - AC I/P:3.0KVAC Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC SAFETY & WITHSTAND VOLTAGE EMC EMI CONDUCTION&RADIATION Compliance to FCC class A Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE, E-Mark ----- Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204 EMS IMMUNITY CHARGE CURRENT (Typ.) 5.5A 2.7A 1.35A 2.7A 1.35A 5.5A AC CHARGER CHARGE VOLTAGE 14.3V 4% 28.5V 4% 57V 4% 14.3V 4% 28.5V 4% 57V 4% MAX OPEN CIRCUIT VOLTAGE 25V 45V 75V 45V 75V 25V SOLAR CHARGE CURRENT (max.) 30A CHARGER 28.5V 4% 57V 4% 28.5V 4% 57V 4% CHARGE VOLTAGE 14.3V 4% 14.3V 4% CONTROL WIRING RJ11 -RS232 (Option) OTHERS DIMENSION 420*220*88mm (L*W*H) 6.85Kg 2pcs/14.7Kg/1.61CUFT PACKING 1.Output derating capacity referenced by curve 1. NOTE 2.Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage. 3.Output derating capacity referenced by curve 2. 4.All parameters not specified above are measured at rated load, 25 of ambient temperature. 5.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage. File Name:TN-1500-SPEC 2008-07-291500W True Sine Wave DC-AC Inverter with Solar Charger TN-1500 s e ri e s Instructions for TN-1500 monitoring software 1. Installation of TN-1500 unit and PC 5 9 1 4 8 3 7 2 6 6 1 Phone Jack RJ11 DB9 FEMALE RJ11 2 3 4 PIN NO. DB9 3 5 2 PIN NO. Figure 1 2. Explanation of Monitoring Manu 2.1 Main Page Inverter TN V.1.1 Setting Statistics R.C. Power off Pause Exit 1 2 3 4 Solar Charge INVERTER 100 100 AC Charge 0 0 5 Battery Loading O/P Voltage 110 V Battery Voltage 54.1 V O/P Frequency 60.0 Hz Internal Temperature 10.0 AC In By pass Utility Voltage 0.0 V TN-1500-143 Power on Remote off Battery low 6 Start Date 2007/12/07 03:13:33 PM Battery used up Reset Date 2007/12/21 01:40:56 PM Stand by saving mode Abnormal Shutdown Figure 2 1. Setting: Adjustment for output voltage, charging related voltage, frequency, and operation mode. Please refer to Figure 3 for details. 2. Statistics: Calculate for the percentage of operating period for each operation mode. Please refer to Figure 4 for details. 3. R.C. Power off: Power can be turned ON or OFF at the remote location. 4. Pause: Stop refreshing the page of monitoring software. 5. Status of unit: Indicating current operating status of TN-1500. 6. Signals that display current condition of the unit. File Name:TN-1500-SPEC 2008-07-29