3000W True Sine Wave DC-AC Inverter with Solar Charger T N- 3000 se ri e s Features : ETrue sine wave output (THD<3%) EHigh surge power up to 6000W EU.P.S. mode and energy saving mode (selectable) EHigh efficiency up to 92% EPower ON-OFF switch EStandby saving mode can be selectable EFront panel indicator for operation status EThermostatically controlled cooling fan EProtections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input polarity reverse / Overload / AC circuit breaker EApplication : Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. EBuilt-in solar / AC charger EOptional monitoring software and connection cable (MW order No.: DS-TN-1500) E3 years warranty E13 SPECIFICATION MODEL TN-3000-112 TN-3000-124 TN-3000-148 TN-3000-212 TN-3000-224 TN-3000-248 RATED POWER (Typ.) 3000W MAXIMUM OUTPUT POWER (Typ.) 3450W for 180 sec. / 4500W for 10 sec. / surge power 6000W for 30 cycles Factory setting set at 110VAC Factory setting set at 230VAC AC VOLTAGE 100 / 110 / 115 / 120VAC selectable by setting button S.W 200 / 220 / 230 / 240VAC selectable by setting button S.W FREQUENCY 60 0.1Hz 50/60Hz selectable by setting button S.W 50 0.1Hz 50/60Hz selectable by setting button S.W OUTPUT WAVEFORM True sine wave (THD<3%) at rated input voltage AC REGULATION (Typ.) 3% TRANSFER TIME (Typ.) 10ms inverter by pass SAVING MODE (Typ.) Default disabled. Load 5W will be changed to standby mode FRONT PANEL INDICATOR Battery voltage level, output load level, saving mode, fault and operation status 24V 48V 24V 48V BAT. VOLTAGE 12V 12V VOLTAGE RANGE (Typ.) Note.3,6 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC DC CURRENT (Typ.) Note.4 300A 150A 75A 300A 150A 75A INPUT 10W standby saving mode NO LOAD DISSIPATION (Typ.) OFF MODE CURRENT DRAW (Typ.) 1mA EFFICIENCY (Typ.) Note.1 88% 90% 91% 89% 91% 92% BATTERY TYPES Open & sealed lead acid battery FUSE 40A*12 40A*6 20A*6 40A*12 40A*6 20A*6 BATTERY 11.3V 22.5V 45V 11.3V 22.5V 45V BAT. LOW ALARM Note.6 INPUT BAT. LOW SHUTDOWN Note.6 10.5V 21V 42V 10.5V 21V 42V PROTECTION REVERSE POLARITY By internal fuse open 90J J5 85J J5 85J J5 80J J5 75J J5 75J J5 OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover OUTPUT SHORT Protection type : Shut down o/p voltage, re-power on to recover OUTPUT 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. PROTECTION OVER LOAD (Typ.) Protection type : Shut down o/p voltage, re-power on to recover CIRCUIT BREAKER AC output: 40A, AC receptacle:15A AC output: 20A, AC receptacle: 15A GFCI PROCTECTION Optional (Only type F) None WORKING TEMP. Note.2 0 ~ +40J 100% load 60J 50% load WORKING HUMIDITY 20% ~ 90% RH non-condensing ENVIRONMENT o STORAGE TEMP., HUMIDITY -30 ~ +70J / -22 ~ +158 F, 10 ~ 95% RH VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes UL458 (only for Type G ) None SAFETY STANDARDS LVD None EN60950-1 SAFETY & WITHSTAND VOLTAGE Bat I/P - AC I/P:3.0KVAC Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC EMC ISOLATION RESISTANCE Bat I/P - AC O/P, Bat I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25J/ 70% RH EMC EMISSION Compliance to FCC class A Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark None EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11 12A 6A 12A 6A CHARGE CURRENT (Typ.) 25A 25A AC CHARGER CHARGE VOLTAGE Note.6 14.3V 28.5V 57V 14.3V 28.5V 57V 45V 75V 45V 75V MAX OPEN CIRCUIT VOLTAGE 25V 25V SOLAR PANEL SHORT CIRCUIT CURRENT (max.) 30A CONTROL WIRING RJ11 -RS232 (Option) OTHERS DIMENSION 466.8*283.5*100mm (L*W*H) 12.9Kg 1pcs/14Kg/1.98CUFT PACKING 1.Efficiency is tested by 2100W, linear load at 13V, 26V, 52V input voltage. NOTE 2.Output derating capacity referenced by curve 1. 3.Input derating capacity referenced by curve 2. 4.DC current is tested by 3000W, linear load at 12V, 24V, 48V input voltage. 5.All parameters not specified above are measured at rated load, 25J of ambient temperature. 6.The tolerance of each voltage value by models is:112/212 0.5V 124/224 1V 148/248 2V File Name:TN-3000-SPEC 2013-01-143000W True Sine Wave DC-AC Inverter with Solar Charger TN- 300 0 series Instructions for TN-3000 monitoring software 1. Installation of TN-3000 unit and PC 5 9 1 4 8 3 7 2 6 6 1 Phone Jack RJ11 DB9 FEMALE RJ11 2 3 4 PIN NO. DB9 3 5 2 PIN NO. Figure 1 2. Explanation of Monitoring Manu 2.1 Main Page Inverter TN V1.38 Setting Statistics R.C. Power off Pause Exit 1 2 3 4 Solar Charge INVERTER 100 100 AC Charge 0 0 5 Battery Loading O/P Voltage 230 V Battery Voltage 13.5 V O/P Frequency 50.0 Hz Internal Temperature 10.0J AC In By pass Utility Voltage 0.0 V TN-3000-212 Power on Remote off Battery low 6 Start Date 2010/01/01 03:13:33 PM Battery used up Reset Date 2010/01/01 01:40:56 PM Stand by saving mode Abnormal Shutdown Figure 2 1. Setting: Adjustment for output voltage, charging related voltage, frequency, and operation mode. Please refer to Figure 3 for details. 2. Statistics: Calculate for the percentage of operating period for each operation mode. Please refer to Figure 4 for details. 3. R.C. Power off: Power can be turned ON or OFF at the remote location. 4. Pause: Stop refreshing the page of monitoring software. 5. Status of unit: Indicating current operating status of TN-3000. 6. Signals that display current condition of the unit. File Name:TN-3000-SPEC 2013-01-14