200W True Sine Wave DC-AC Power Inverter TS-20 0 serie s Features : ETrue sine wave output (THD<3%) EHigh surge power up to 400W EHigh efficiency up to 88% EFanless design, cooling by free air convention EBuilt-in remote ON-OFF control EFront panel indicator for operation status EPower ON-OFF switch EProtections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input reverse polarity / Overload EApplication : Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. E3 years warranty E13 SPECIFICATION MODEL TS-200-112 TS-200-124 TS-200-148 TS-200-212 TS-200-224 TS-200-248 RATED POWER 200W MAXIMUM OUTPUT POWER 230W for 180 sec. / 300W for 10 sec. / surge power 400W for 30 cycles(typ.) Factory setting set at 110VAC Factory setting set at 230VAC AC VOLTAGE 100 / 110 / 115 / 120VAC selectable by setting button S.W 200 / 220 / 230 / 240VAC selectable by setting button S.W OUTPUT FREQUENCY 60 0.1Hz 50/60Hz selectable by setting button 50 0.1Hz 50/60Hz selectable by setting button WAVEFORM True sine wave (THD<3%) at rated input voltage AC REGULATION Note.1 3.0% at rated input voltage FRONT PANEL INDICATOR Operation status Green : normal, Orange(flashing) : remote control OFF, Red : abnormal BAT. VOLTAGE 12V 24V 48V 12V 24V 48V VOLTAGE RANGE (Typ.) Note.3 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC DC CURRENT (Typ.) 20A 10A 5A 20A 10A 5A INPUT 1.25A NO LOAD CURRENT DRAW (Typ.) 0.63A 0.32A 1.25A 0.63A 0.62A OFF MODE CURRENT DRAW 1mA EFFICIENCY (Typ.) Note.1 86% 87.5% 88% 86% 87.5% 88% BATTERY TYPES Open & sealed Lead Acid FUSE 30A*2 30A*1 15A*1 30A*2 30A*1 15A*1 BATTERY 11.3 4% 22.5 4% 45 4% 11.3 4% 22.5 4% 45 4% BAT. LOW ALARM INPUT BAT. LOW SHUTDOWN 10.5 4% 21 4% 42 4% 10.5 4% 21 4% 42 4% PROTECTION BAT. POLARITY By internal fuse open 85J J5 80J J5 80J J5 85J J5 80J J5 80J J5 OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover by internal RTH1 detect power transistor OUTPUT SHORT Protection type : Shut down o/p voltage, re-power on to recover OUTPUT PROTECTION 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. OVER LOAD (Typ.) Protection type : Shut down o/p voltage, re-power on to recover GFCI PROCTECTION Optional (Only type F) None FUNCTION REMOTE CONTROL Open : Normal work Short : Remote off -10 ~ +35J 100% load +60J 50% load WORKING TEMP. -10 ~ +40J 100% load, +60J 50% load WORKING HUMIDITY 20% ~ 90% RH non-condensing ENVIRONMENT o STORAGE TEMP., HUMIDITY -30 ~ +70J / -22 ~ +158 F, 10 ~ 95% RH VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes None SAFETY STANDARDS Design refer to UL458 LVD None EN60950-1 SAFETY & WITHSTAND VOLTAGE Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC EMC ISOLATION RESISTANCE Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25J/ 70% RH EMC EMISSION Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark Compliance to FCC class A None EMC IMMUNITY Compliance to EN61000-4-2,3,8 o MTBF 106.2K hrs min. MIL-HDBK-217F (25 C) OTHERS DIMENSION 205*158*59mm (L*W*H) 1.63Kg 6pcs/10.8Kg/1.44CUFT PACKING 1.Efficiency & AC regulation is tested by 200W, linear load at 13V/26V/52V input voltage. NOTE 2.All parameters not specified above are measured at rated load, 25J of ambient temperature. 3.The tolerance of each voltage value by models is:112/212 0.5V 124/224 1V 148/248 2V File Name:TS-200-SPEC 2013-01-14 200W True Sine Wave DC-AC Power Inverter TS-20 0 serie s TS 200 112 A A :TYPE A OUTLET B :TYPE B OUTLET 12:12VDC True sine wave inverter C :TYPE C OUTLET Bat. Voltage: 24:24VDC D :TYPE D OUTLET 48:48VDC E :TYPE E OUTLET 1:110VAC F :TYPE F OUTLET Output: O/P Wattage:200W 2:230VAC AC Output Receptacles (optional) Receptacle type TYPE-A TYPE-B TYPE-C TYPE-D TYPE-E TYPE-F Country USA EUROPE AUSTRALIA U.K JAPAN GFCI Certificate E13 E13 E13 Mechanical Specification Derating Curve Unit:mm R.C Connector : JST B-XH or equivalent Open Normal work 100 Short Remote off 24.82 TS-200-2xx 80 60 TS-200-1xx 50 40 20 11 8.9 -10 0 10 20 30 35 40 50 60 70 (HORIZONTAL) ENVIRONMENT TEMPERATURE (J) 9 AC OUTPUT Status Setting Type-A Status AC OUTPUT Setting Type-B 147 158 File Name:TS-200-SPEC 2013-01-14 7 18 12 10.7 120 42.5 59 205 LOAD (%) Reverse Polarity ON Will Damage The Unit. OFF Chassis Ground R.C