Filename: tfs 800.doc Version 1.3 03.04.2008 VI TELEFILTER Filter specification TFS 800 1/5 Measurement condition Ambient temperature: 23 C Input power level: 0 dBm Terminating impedance: Input: 50 Output: 50 Characteristics Remark: The maximum attenuation in the pass band is defined as the insertion loss a . The nominal frequency f is fixed at 800 MHz without any tolerance or limit. N e The values of absolute attenuation a are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating abs temperature range is included in the production tolerance scheme. D a t a typ. value tolerance / limit Insertion loss a 1,7 dB max. 3,0 dB e Nominal frequency f - 800,0 MHz N Passband PB - f 6,0 MHz N Pass band ripple 0,5 dB max. 1,0 dB Absolute attenuation a abs 0,3 MHz 770 MHz 43 dB min. 40 dB 820 MHz 836 MHz 44 dB min. 10 dB 881 MHz 1200 MHz 48 dB min. 40 dB 1200 MHz 2000 MHz 33 dB min. 20 dB VSWR within PB 1,8 : 1 max. 2,2 : 1 Input power level - max. 10 dBm Operating temperature range OTR - - 40 C ... + 80C Storage temperature range - - 40 C ... + 85C Temperature coefficient of frequency TC * - 42 ppm / K - f *) f(Hz) =TC (ppm/K) x(T-T ) x f (MHz) f 0 To Generated: Checked / Approved: Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft vectron.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 800.doc Version 1.3 03.04.2008 VI TELEFILTER Filter specification TFS 800 2/5 Filter characteristic 0 0 5 -1 4.5 -10 -2 4 -20 -3 3.5 -4 3 -30 -5 2.5 -40 -6 2 -7 1.5 -50 -8 1 -60 -9 0.5 -70 -10 0 0 200 400 600 800 1000 1200 1400 1600 1800 2000 778800 778855 779900 779955 880000 880055 881100 881155 882200 frequency in MHz frequency in MHz Construction and pin connection (All dimensions in mm) 1 Ground 7 5 2 Input 3 Ground 4 Ground 5 Ground 800 6 Output 7 Ground W14 8 Ground 1 3 Date code 2,54 1 3 Date code: Year + week W 2008 X 2009 A 2010 ... 7 5 1,78 50 Test circuit L1 2 6 L2 SAW 1, 3, 4, 5, 7, 8 Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft vectron.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. 120%%d magnitude in dB 0,1 0,6 1,2 Max. SQ 3,81 +0,2/-0,1 1,78 magnitude in dB VSWR