*LAST TIME BUY: 3/31/2015. CLICK HERE FOR OBSOLESCENCE NOTICE OF 10/31/2014. cPCI200A-1C Series www.murata-ps.com 200W 3Ux4HP AC/DC CompactPCI SELECTION GUIDE Output Current To Be Discontinued* Model Number Power 5V 3.3V 12V -12V For full details go to www.murata-ps.com/rohs CPCI200A-1C 200W 25A 30A 5A 1A Yes Yes INPUT CHARACTERISTICS Parameter Conditions Min Typ Max Units Input Operating Voltage 90 264 Vac Input Frequency 47 63 Hz Input Current 3.5 A rms Power Factor 0.95 0.98 0.99 FEATURES Inrush Current 240Vac 35 A pk n 3Ux4HP package Leakage Current 240VAC, 63Hz 1 mA n 200W power at 0-50C OUTPUT CHARACTERISTICS n PICMG 2.11 Compliant Output Current n Widerange 90-264VAC Input 1 Output Nominal Voltage Total Regulation Min Max n Active power factor correction to EN61000-3-2 2 3 V1 +5.0Vdc 1A 25A +4/-2% n Class A conducted EMI performance 2 3 V2 +3.3Vdc 1 A 30A +4/-2% n 47-pin I/O Connector V3 +12Vdc 0A 5A 4% V4 -12Vdc 0A 1A 4% n 80% efficiency Parameter Conditions Min Typ Max Units n Full power with just 250lfm airflow Temperature Coefficient 0.02 %/C n Hot-swap capable PARD (V1 & V2) 20MHz bandwidth 50 mV p-p PARD (V3 & V4) 20MHz bandwidth 120 180 mV DESCRIPTION p-p Output Power 50C, 250lfm airflow 0 200 W The cPCI200A-1C is a high-reliability, 200W, 3Ux4HP CompactPCI power supply developed for chassis Output Power 70C, 250lfm airflow 0 100 W with airflows as low as 250lfm. The use of resonant V, 50% load step 5 %V nom conversion and ORing FETs yields high efficiency which Transient Response consequently permits packaging of this product in a Settling time 500 sec compact, single card slot format (4HP). Over-Voltage Protection V1, V2, & V3 125 135 %V nom The ORing FETs, current sharing, and synchronous start 4 Minimum Load V1 or V2 1 A control allow the cPCI200A-1C to be operated in N+n Output Holdup Time Full load, low line 12 16 msec parallel-redundant configurations. The low leakage current permits redundant configurations to comply 5 Remote Sense Compensation V1, V2, & V3 250 mV with safety standards. The unit is capable of hot-swap Current Share Tolerance V1-V3 I >25% 10 % o performance to support high-availability enterprise applications. Pri-Sec 3 kVac With a widerange input of 90-264VAC, safety Isolation Pri-Chassis 1.5 kVac agency approvals to UL60950 and EN60950, EMI Sec-Chassis 500 Vac compliance to Class A FCC and EN55022 standards, the cPCI200A-1C was designed with globally-deployed Notes: 1. Total regulation includes line, load, and cross regulation. systems in mind. Additional features include remote 2. Maximum combined power from V1 & V2 not to exceed 125W. sense compensation, unit enable control (EN ), output 3. Minimum load requirement of 1A may be fulfilled on either V1 or V2, but need not be applied to both. inhibit control (INH ), output fault signal (FAL ), and The unit will operate with less than the stated minimum, but full load on V3 & V4 is only achievable with the minimum load requirement met on V1 and/or V2. thermal warning signal (DEG ). LEDs are provided for 4. Minimum load is for a single unit units operated in parallel may require additional load to achieve full visual indication of input power presence and output power on outputs V3 and V4. fault condition. 5. Unit automatically reverts to local sensing if the sense lines are opened. Unit is protected against shorted or reversed sense lines. www.murata-ps.com/support cPCI200A-1C Series.E01 Page 1 of 4cPCI200A-1C Series 200W 3Ux4HP AC/DC CompactPCI GENERAL CHARACTERISTICS Parameter Conditions Min Typ Max Units Efficiency Full load, 240Vac 79 81 % PFC Converter 100 kHz Switching Frequency Main Converter 130 kHz MTBF Calculated per Telcordia SR-332, Issue 1, 50C, 250lfm, ground benign 200 khrs Weight Unpackaged 620 g PROTECTION Inception Parameter Conditions/Response Units Min Typ Max Thermal Shutdown Automatic recovery upon restoration to operational temperatures 100 C Input Current Limit 3 A rms Input Protection Internal line fuse Schurter 0034.6981 or equivalent 4 A rms Over-voltage Protection V1, V2, & V3 125 135 %V nom Parameter Conditions/Response Outputs are individually protected against overloads and indefinite short circuit with automatic recovery upon removal of the fault condition. Output Overload Protection Overload response for outputs V1-V3 is constant-current mode. Overload response for V4 is foldback hiccup mode in response to a hard short. Design Verification Testing (DVT) confirms that voltage excursions on the output buses resulting from insertion/extraction events do not exceed the specified maximum of 5%. However, routing of power and signal lines in the mating backplane is critical to minimization of such excursions. Hot-Swap Capability In addition, performance can be critically affected by load characteristics including resistance, negative resistance, and reactive components. While the control loop responses have been designed for optimum hot-swap performance over a wide range of load characteristics, there may be in- stances where the voltage excursions exceed published specifications. In such cases, the control loop responses can be modified to perform optimally. Output Fault Isolation Output isolation devises are present in all outputs to isolate faults within a failed power supply. STATUS & CONTROL SIGNALS & INDICATORS Name Description Short pin on connector will enable the outputs when the mating pin is grounded. Supply will not power up until this pin is engaged Enable (EN ) to its mate in the backplane. Unit output will be inhibited as pin is disengaged from the mating connector. Output Inhibit (INH ) Secondary referenced active low, TTL compatible. Logic 0 or short circuit to output return inhibits all outputs. Output Fault (FAL ) Secondary referenced TTL compatible. Logic 0 denotes that one of the output voltages has fallen below the lower regulation limit. Connection of the sense leads across the load at the desired point of regulation will compensate for voltage distribution drops up to 250mV Remote Sense (RS+, RS-) between the output terminals of the power supply and the point of connection. The output is protected against shorted or open leads. Each of the Remote Sense lines must be terminated to the corresponding output and return lines in order guarantee all performance specifications. Thermal Warning (DEG ) Secondary referenced TTL compatible. Logic 0 denotes a thermal warning nominally, 10C prior to thermal shutdown. Interconnection of the sync start leads between cPCI200A-1 units connected in parallel permits synchronous starting to support loads Sync Start (Sync) that exceed the maximum for a single unit. Pin 35 (V1 Share) is used for the synchronous start function. An LED will illuminate red if the output voltages are not within specification, coincident with assertion of the FAL signal. This LED Fault Indicator LED will also illuminate amber if the output is inhibited. Power Present Indicator LED A green LED will be illuminated when the input voltage is present and above the minimum requirement. ENVIRONMENTAL CHARACTERISTICS Parameter Conditions Min Typ Max Units Ambient Operating Temperature 0 50 C Ambient Storage Temperature -40 125 C Operating Humidity Non-condensing 10 90 % Storage Humidity Non-condensing 5 90 % Operating. De-rate operating ambient temperature by 2C per 1000ft above 5000ft. -200 10000 ft Altitude Storage -200 50000 ft www.murata-ps.com/support cPCI200A-1C Series.E01 Page 2 of 4