Embedded Power for
Business-Critical Continuity
Rev. 10.23.12_131
LCM600 Series
1 of 6
LCM600
600 Watts
Bulk Front End
Total Power: 600 W
# of Outputs: Single
Output: 12 to 60 V
Optional 5.0 V standby
Electrical Specifications
Input
Input ra nge: 85 - 264 Vac (Operating)
Special Features
115/230 Vac (Nominal) Input through standard IEC connector/
TERMINAL BLOCK
600 W output power
Low Cost Frequency: 47 - 440 Hz, Nominal 50/60
2.4 x 4.5 x 7.5
Input fusing: Internal 10 A fuses, both lines fused
7.41 W/cu-in
Inrush current: 25 A peak, either hot or cold start
Industrial/Medical safety
Power factor: 0.99 typical, meets EN61000-3-2
-40 C to 70 C with derating
Optional 5 V @ 2 A Housekeeping Harmonics: Meets IEC 1000-3-2 requirements
High Efficiency: 89% typical
Input current: 8 A RMS max input current, at 100 Vac
Variable speed Smart Fans
Hold up time: 20 ms minimum for Main O/P, at full rated load
DSP controlled front end
Efficiency: > 89% at full load
Conformal coat option
Leakage current: < 0.3 mA at 264 Vac
20% adjustment range
Margin programming
ON/OFF power switch: N/A
O R-ing FE T
Power line transient: MOV directly after the fuse
Ter minal block input option
Isolation:
PRI-Chassis 2000 VAC Basic
PRI-SEC 3000 VAC Reinforced
Compliance
SEC-Chassis 500 VDC
EMI Class B
LCM600Q Efficiency Without the 5 Vsb
EN61000 Immunity
92.00
90.00
88.00
86.00
100 Vac
Safety
84.00
230 Vac
82.00
UL 60950-1
508/1598/1433 80.00
60601-1
78.00
CSA 60950-1
76.00
VDE 60950-1
25 50 75 100
60601
Loading %
China CCC
CB Scheme Report/Cert
Efficiency %Embedded Power for
Business-Critical Continuity
Rev. 10.23.12_131
LCM600 Series
2 of 6
Output
Output rating: See table 1 85 - 264 Vac
Set point: 0.5% 85 - 264 Vac
Total regulation range: Combined line/load/transient when measured at output terminal
Main output 2%
5 Vsb 1%
Rated load: 600 W maximum Derate linear to 50% from 50 C to 70 C
Minimum load: No loss of regulation
Main output @ 0.0 A
5 Vsb @ 0.0 A
Output noise (PARD): 1% max p-p
Main output
50 mV max p-p
5 Vsb output
Measured with a 0.1 F Ceramic and 10 F Tantalum Capacitor on
any output, 20 MHz
Output voltage overshoot:
No overshoot/undershoot outside the regulation band during on or
off cycle
Transient response: < 300 Sec
50% load step @ 1 A/s
Step load valid between 10% to 100% of output rating
Recovery time to within 1% of set point at onset of transient
Max units in parallel: Up to 10
Short circuit protection: Protected, no damage to occur Bounce mode
Remote sense: Compensation up to 500 mV
Output isolation: Standard per safety requirements
Forced load sharing: To within 10% of all shared outputs Analog sharing control
Overload protection (OCP):
105% to 125% Main output
120% to 170% 5 Vsb output
Overvoltage protection (OVP): 125% to 145% 12 V output
110% to 125% 5 Vsb output
Overtemp protection: 10 - 15 C above safe operating area Both PFC and output converter monitored
Fan Fault Protection: For-N option only. Will shutdown output and DC_OK
Environmental Specifications
Operating temperature: -40 C to +70 C, linear derating to 50% from 50 C to 70 C
Storage temperature: -40 C to +85 C
Humidity: 20 to 90%, non-condensing. Operating. Conformal coat option available
Fan noise: < 45 dBA, 80% load at 30 C -N Low Noise Option <35 dBA,80% Load at 30 C
Altitude: Operating - 15,000 feet
Storage - 30,000 feet
Shock: MIL-STD-810F 516.5, Procedure I, VI. Storage
Vibration: MIL-STD-810F 514.5, Cat. 4, 10. Storage
Ordering Information
Current
Model Nominal Output Set Point Adjustment Output Ripple Power Combined Line/
Output
Number* Voltage Set Point Tolerance Range P/P Max. Load Regulation
Min Max
LCM600L 12 V 12 V 0.5% 9.6 - 14.4 V 0 A 52 A 120 mV 600 W 2%
LCM600N 15 V 15 V 0.5% 12.0 - 19.5 V 0 A 44 A 150 mV 600 W 2%
LCM600Q 24 V 24 V 0.5% 19.2 - 28.8 V 0 A 27 A 240 mV 600 W 2%
LCM600U 36 V 36 V 0.5% 28.8 - 43.2 V 0 A 16.7 A 240 mV 600 W 2%
LCM600W 48 V 48 V 0.5% 38.4 - 57.6 V 0 A 14 A 280 mV 600 W 2%
*Note: Add -T for terminal block instead of IEC input.
Add-4 For 5V, SB