process yellow 116 1375 1797 375 3405 313 2985 240 Embedded Power for Business-Critical Continuity 242 2607 Rev.11.02.11 65 NFS40 Series 1 of 4 652 NFS40 Series SIngle and triple output Total Power: 40 - 50 W Input Voltage: 85 - 264 Vac 120 - 370 Vdc of Outputs: Single, triple Electrical Specifications Input Special Features Voltage adjustability: +5 V output on triples 5.0% 5.0 x 3.0 x 1.2 inch package Vout on singles 5.0% (1U applications) Line regulation: Main output 0.2% Industry standard package LL to HL, FL Auxiliary outputs 1.0% Overvoltage and Load regulation: Main output 2.0% short circuit protection FL to NL Auxiliary outputs 5.0% 40 W with free air convection Transient response: +5 V (1.5 - 3 A) 120 mV max. dev. 50 W with 20 CFM forced air 500 s recovery EN55022, EN55011 conducted noise level B Temperature coefficient: All outputs 0.02%/C UL, VDE and CSA Overvoltage protection: +5 V output S3.15 A, 250 Vac In live and neutral safety approvals Output power limit: Primary power limited 90 W input power limit Available RoHS compliant 2 year warranty Short circuit protection: Single outputs Continuous Multiple outputs Short term Output Input voltage range: Universal input 85 - 264 Vac 120 - 370 Vdc Input frequency range: 47-440 Hz Max. input surge current: 132 Vac, cold start 12 A max. Safety 264 Vac, cold star 24 A max. VDE0805/EN60950/ Safety ground leakage current: 110 Vac, 60 Hz 0.13 mA, max. IEC950/IEC1010 230 Vac, 50 Hz 0.32 mA, max. File No. 10401-3336-0044 License No. 2559 UL60950-1 File No. E13002 CSA C22.2 No. 950 File No. LR41062Cprocess yellow 116 1375 1797 375 3405 313 2985 240 242 Embedded Power for Business-Critical Continuity 2607 Rev.11.02.11 65 NFS40 Series Specifications 2 of 4 652 All specifications are typical at nominal input, full load at 25 C unless otherwise stated (11, 12) EMC Charateristics Conducted emissions: EN55022, FCC part 15 Level B Radiated emissions: EN55022 Level A ESD air: EN61000-4-2, level 3 Perf. criteria 1 ESD contact: EN61000-4-2, level 4 Perf. criteria 1 Surge: EN61000-4-2, level 3 Perf. criteria 1 Fast transients: EN61000-4-4, level 3 Perf. criteria 1 Radiated immunity: EN61000-4-3, level 3 Perf. criteria 2 Conducted immunity: EN61000-4-6, level 3 Perf. criteria 2 General Specifications Hold-up time: 110 Vac, 40 W 14 ms 230 Vac, 40 W 110 ms Efficiency: 70% typical Isolation voltage: Input/output 3000 Vac Input/chassis 1500 Vac Switching frequency: Variable Approvals and standards: (see VDE0805, EN60950, IEC950, IEC1010, Notes 9, 13) UL1950, CSA C22.2 No. 950 Weight: 280 g (9.88 oz) MTBF demonstrated: MIL-HDBK-217E 170,000 hours Environmental Specifications Thermal performance: Operating 0 C to +70 C (See notes 8, 10) Non-operating -40 C to +85 C 50 C ambient temp., 40 W convection cooled Forced air cooling 50 W 20 CFM +50 C to +70 C ambient Derate linearly to 50% load Peak (60 seconds) 60W Relative humidity: Non-condensing 5 to 80% RH Altitude: Operating 10,000 feet max. Non-operating 40,000 feet max. Vibration (See Note 11): 5-500 Hz 2.4 G rms peak