D1U54P-W-650-12-HBxC Series 54mm 1U Front End AC-DC Power Supply Converter PRODUCT OVERVIEW The D1U54P-W-650-12-HBxC series are very high efciency 650 watt power factor corrected front end supplies with a 12V main output and a 12V Standby. An active (analogue) current share characteristic is provided to allow units to operate in parallel. The power supply may be hot plugged recovers from overtemperature faults, and has status LEDs on the front panel in addition to hardware signal logic and PMBus status signals. The low prole 1U package and 21.4W/cubic inch power density make them ideal for delivering reliable, efcient power to networking equipment, workstations, storage systems and other 12V distributed power architectures. ORDERING GUIDE Murata Internal Power Output Main Standby Part Number Airow Part Number 90 to 264Vac Output Output D1U54P-W-650-12-HB3C M1877 Front to Back 650W 12Vdc 12Vdc D1U54P-W-650-12-HB4C M1876 Back to front FEATURES INPUT CHARACTERISTICS 650W output power Parameter Conditions Min. Nom. Max. Units 94% efciency at 50% load Input Source Voltage Operating Range 90 115/230 264 Vac 12V main output Input Source Frequency 47 50/60 63 Hz 12V standby output Turn-on Input Voltage Ramp up 74 84 Vac 1U height: Turn-off Input Voltage Ramp down 70 80 2.15 x 9.0 x 1.57 Maximum current at Vin = 100Vac 650W 10 Arms 54.5mm x 228.6mm x 40mm Inrush Current Cold start between 0 to 200msec 25 Apk Full digital control At 230Vac, 100% load 0.96 Power Factor 21.4 Watts per cubic inch density At 230Vac, 50% load 0.95 N+1 redundancy capable, including hot plugging At 230Vac, 20% load 90 Active (analogue) current sharing on 12V main Efficiency (excluding fan load) At 230Vac, 50% load 94 % output ORING FET At 230Vac, 100% load 91 Overvoltage, Overcurrent, Overtemperature OUTPUT VOLTAGE CHARACTERISTICS protection Nominal Internal cooling fan (variable speed) Parameter Conditions Min. Typ. Max. Units Output PMBus/I2C interface with status indicators Voltage RoHS compliant Output Set Point Accuracy 50% load Tamb =25C 11.96 12.00 12.04 Vdc Two Year Warranty Setpoint temperature line % Line and Load Regulation -1.0% +1.0 and load 1, 2 12V Ripple Voltage & Noise 20MHz Bandwidth 120 mV p-p Output Current Range 0 54.2 A Load Capacitance 500 4000 F Output Set Point Accuracy 50% load Tamb = 25C 11.96 12.00 12.04 Setpoint temperature line Vdc Line and Load Regulation 11.7 12.3 12VSB and load 1 Ripple Voltage & Noise 20MHz Bandwidth 120 mV p-p Output Current 0 2 A www.murata-ps.com/en/3d/acdc.html 1 Ripple and noise are measured with 0.1 F of ceramic capacitance and 10 F of tantalum capacitance on each of www.murata-ps.com/en/3d/acdc.html the power supply outputs. A short coaxial cable to the measurement scope input, is used. www.murata-ps.com/en/3d/acdc.html 2 Measurements assume the use of the minimum load capacitance as specified for the main 12V output and a www.murata-ps.com/en/3d/acdc.html minimum load of 5%. www.murata-ps.com/en/3d/acdc.html Below 5% loading the overall voltage deviation shall be within 500mV due to zero load skip cycle mode of www.murata-ps.com/en/3d/acdc.html operation. Available now at: www.murata-ps.com/en/3d/acdc.html Test Certificate For full details go to and Test Report www.murata-ps.com/rohs www.murata-ps.com/support D1U54P-W-650-12-HBxC.A02 Page 1 of 9 D1U54P-W-650-12-HBxC Series 54mm 1U Front End AC-DC Power Supply Converter OUTPUT CHARACTERISTICS Max. Parameter Conditions Min. Typ. Units Startup Time AC ramp up Note: Following a turn off of the 12V Main output (for any reason whatsoever) the 3 s output shall not be allowed to turn on again for 1sec (even if all necessary operating conditions are met). Main 12V, 50% load step, 1A/s di/dt 5 % Transient Response 500 s 12VSB, 50% load step, 1A/s di/dt Current sharing accuracy (Main 12V output) >10% load (* percentage of full load) 5* % 5 % Hot Swap Transients Holdup Time (Total Effective Hold Up - See Timing Waveforms) Full AC Input Source Range full load 12 ms ENVIRONMENTAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Storage Temperature Range -40 70 C Operating Temperature Range 90V-264Vac, 650W -5 50 Operating Humidity Noncondensing +45C 5 90 % Storage Humidity 5 95 Altitude (without derating at 40C) 3000 m Shock 30G non-operating Sine sweep 5-200Hz, 2G Operational Vibration random vibration, 5-500Hz, 1.11G MTBF(Target) Per Telcordia SR-332 M1C1 40C 576K hrs CAN/CSA C22.2 No 60950-1-07, Am.1:2011, Am 2:2014 ANSI/UL 60950-1-2014 IEC60950-1:2005 (2nd Ed.), Am 1:2009 + Am 2:2013 Safety Approvals EN 60950-1:2006+A11:2009 +A1:2010 +A12:2011 +A2:2013 BSMI CNS14336-1 (099/09/30) CNS13438 ((095/06/01) CCC GB4943.1-2011 GB9254-1-2008 GB17625, 1-2012 Input Fuse Power Supply has internal 12.5A/250V fast blow fuse on the AC line input Weight 1.63 lbs (0.741 kg) AIRFLOW PRESSURE VS. FLOW (PQ) CURVES D1U54P-W-650-12-HB3C & D1U54P-W-650-12-HB4C D1U54-W-650-12-HBxC P & Q CURVE Orignal curve in Excel spreadsheet at following location: M1845 airflow meas 01-12-2015.xlsx 250 200 150 Airflow Front to Back 100 Airflow Back to Front 50 0 0 2 4 6 8 10 PSU airflow (CFM) Notes: 1. The above curves represent performance based upon the use of a 20mm thickness fan. 2. Curves recorded at room ambient (circa 25C). 3. Curves generated with intermal fan running at 100% duty cycle www.murata-ps.com/support D1U54P-W-650-12-HBxC.A02 Page 2 of 9 Back Pressure (Pa)