MGJ6 Three Phase Bridge Series www.murata-ps.com 5.7kVDC 6W Quad Output Isolated Gate Drive SM DC-DC Converters SELECTION GUIDE Output 1 VHA / Output 2 VHB Output 3 Output 4 VL VHC 1 Order Code Input Voltage FEATURES Range No opto feedback VmA W VmA W V Patent protected MGJ6Q05P24MC 4.5 - 9 24 42 1 24 125 3 Four isolated output voltages suitable MGJ6Q12P24MC 9 - 18 24 42 1 24 125 3 for po wering IGBT/SiC & Mosfet ga te drives MGJ6Q24P24MC 18 - 36 24 42 1 24 125 3 simultaneously in a three phase bridge SELECTION GUIDE (Continued) conguration Output 1 VHA / Output 2 VHB Output 4 VL Reinforced insulation to UL60950 with 8mm Output 3 VHC creepage & clearance recognition pending ANSI/AAMI ES60601-1 recognition pending Characterised dv/dt immunity 80kV/ s at 1 Order Code 1.6kV Input Characterised partial discharge performance Voltage Range 5.7kVDC isolation test voltage Hi Pot Test % mVp-p % mVp-p V Ultra low coupling capacitance typically 15pF MGJ6Q05P24MC 4.5 - 9 2 3 100 150 2 3 100 150 MGJ6Q12P24MC 9 - 18 2 3 70 120 2 3 70 120 DC link voltage 3kVDC MGJ6Q24P24MC 18 - 36 2 3 70 120 2 3 70 120 5V, 12V & 24V input voltages SELECTION GUIDE (Continued) 105C operating temperature 3 MTTF PRODUCT OVERVIEW Offering four isolated output voltages of 24V, the 1 Order Code MGJ6 series of DC-DC converters is ideal for powering high side and low side gate drive circuits simultaneously for IGBTs, Silicon and Silicon V mA % kHrs Carbide Mosfets in three phase circuits.The MGJ6 MGJ6Q05P24MC 5 1500 76 79.5 series is characterised for high isolation and dv/dt MGJ6Q12P24MC 12 600 81 84 requirements commonly seen in bridge circuits used in motor drives and inverters. MGJ6Q24P24MC 24 300 82 85 1. Components are supplied in tape and reel packaging, please refer to tape and reel specication section. Orderable part numbers are ww MGJ6QXXP24MC-R7 (23 pieces per reel), or MGJ6QXXP24MC-R13 (92 pieces per reel). 2. See ripple & noise test method. 3. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model at TA=25C with nominal input voltage at full load. All specications typical at TA=25C, nominal input voltage and rated output current unless otherwise specied. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support KDC MGJ6C-3P.B02 Page 1 of 14 Nominal Input Voltage Load Regulation (Typ) Rated Output Voltage Input Current at Rated Load Load Regulation (Max) Rated Output Current Efciency 2 Ripple & Noise (Typ) (Min) Output Power 2 Ripple & Noise (Max) Efciency (Typ) Load Regulation (Typ) Rated Output Voltage Load Regulation (Max) MIL 217 Rated Output Current 2 Ripple & Noise (Typ) Telecordia Output Power 2 Ripple & Noise (Max)MGJ6 Three Phase Bridge Series 5.7kVDC 6W Quad Output Isolated Gate Drive SM DC-DC Converters INPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 5V input types 4.5 5 9 Voltage range 12V input types 9 12 18 V 24V input types 18 24 36 Turn on threshold MGJ6Q05 3.8 Turn off threshold MGJ6Q05 3.2 Turn on threshold MGJ6Q12 8.1 Under voltage lock out V Turn off threshold MGJ6Q12 7.5 Turn on threshold MGJ6Q24 16.7 Turn off threshold MGJ6Q24 16.3 5V input types 30 mA Input ripple current 12V input types 45 p-p 24V input types 25 OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Minimum load Below 10% load, output may rise to 30V maximum voltage 10 % 5V output types +4 / -1 Voltage set point accuracy % All other output types +3 / -2 Total regulation 10 % Line regulation Low line to high line 0.5 1 % ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Flash tested for 1 second (input to output) 4000 VAC Flash tested for 1 second (output to output) 2500 Isolation test voltage Qualication tested for 1 minute (input to output) 5700 VDC Qualication tested for 1 minute (output to output) 3000 Resistance Viso = 1kVDC 100 G Continuous barrier withstand voltage Non-safety barrier application 3000 VDC Input to output 8 Creepage & clearance mm Output to output 8 Primary to Output 1 VHA 15 Primary to Output 2 VHB 15 Isolation capacitance pF Primary to Output 3 VHC 15 Primary to Output 4 VL 15 GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Power Consumption Disable pin pulled low 45 mW Switching frequency 100 kHz TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Operation See derating graphs -40 105 Storage -55 125 C 5V input types 25 Product temperature rise above ambient 100% Load, Nom VIN, Still Air All other input types 19 ABSOLUTE MAXIMUM RATINGS Short-circuit protection Continuous Input voltage, MGJ6 5V input types 12V Input voltage, MGJ6 12V input types 20V Input voltage, MGJ6 24V input types 40V www.murata-ps.com/support KDC MGJ6C-3P.B02 Page 2 of 14