MGJ6 Series www.murata-ps.com 5.2kVDC Isolated 6W Gate Drive SM DC/DC Converters SELECTION GUIDE Output 1 Output 2 1 Order Code Input Voltage Typical Range Application FEATURES VmA W VmA W V See page 3 No opto feedback MGJ6T05150505MC 4.5 - 9 IGBT +15 240 3.6 -10 240 2.4 Patents Pending MGJ6T12150505MC 9 - 18 IGBT +15 240 3.6 -10 240 2.4 Optimised bipolar output voltages for IGBT/ MGJ6T24150505MC 18 - 36 IGBT +15 240 3.6 -10 240 2.4 SiC & Mosfet gate drives MGJ6T05150505MC 4.5 - 9 SiC +20 240 4.8 -5 240 1.2 Congurable dual outputs for all gate drive applications: +15V/-5V, +15V/-10V & +20V/- MGJ6T12150505MC 9 - 18 SiC +20 240 4.8 -5 240 1.2 5V outputs MGJ6T24150505MC 18 - 36 SiC +20 240 4.8 -5 240 1.2 Reinforced insulation to UL60950 MGJ6T05150505MC 4.5 - 9 MOSFET +15 300 4.5 -5 300 1.5 recognized MGJ6T12150505MC 9 - 18 MOSFET +15 300 4.5 -5 300 1.5 ANSI/AAMI ES60601-1 1MOPP/2MOOPs MGJ6T24150505MC 18 - 36 MOSFET +15 300 4.5 -5 300 1.5 recognized Characterised dv/dt immunity 80kV/ s at 1.6kV SELECTION GUIDE (Continued) Characterised partial discharge performance Output 1 Output 2 5.2kVDC isolation test voltage Hi Pot Test Ultra low coupling capacitance 15pF 1 DC link voltage 3kVDC Order Code 5V, 12V & 24V input voltages Input Voltage Typical 105C operating temperature Range Application % mVp-p % mVp-p V See page 3 PRODUCT OVERVIEW MGJ6T05150505MC 4.5 - 9 IGBT 5 10 120 200 5 10 118 150 Offering congurable dual output voltages of +15V/- 10V, +20V/-5V and +15V/-5V, the MGJ6 series of MGJ6T12150505MC 9 - 18 IGBT 5 10 148 200 5 10 116 150 DC-DC converters is ideal for powering high side MGJ6T24150505MC 18 - 36 IGBT 5 10 148 200 5 10 110 150 and low side gate drive circuits for IGBTs, Silicon and Silicon Carbide Mosfets in bridge circuits. MGJ6T05150505MC 4.5 - 9 SiC 5 10 169 275 5 10 59 75 A choice of asymmetric output voltages allows optimum drive levels for best system efciency MGJ6T12150505MC 9 - 18 SiC 5 10 206 275 5 10 58 75 and EMI. The MGJ6 series is characterised for high MGJ6T24150505MC 18 - 36 SiC 5 10 203 275 5 10 55 75 isolation and dv/dt requirements commonly seen in bridge circuits used in motor drives and inverters. MGJ6T05150505MC 4.5 - 9 MOSFET 5 10 120 200 5 10 59 75 A disable/frequency synchronisation pin simplies MGJ6T12150505MC 9 - 18 MOSFET 5 10 148 200 5 10 58 75 EMC lter design. The MGJ6 protection features include short circuit protection and overload MGJ6T24150505MC 18 - 36 MOSFET 5 10 148 200 5 10 55 75 protection. 1. Components are supplied in tape and reel packaging, please refer to package specication section. Orderable part numbers are MGJ6T05150505MC-R7 (23 pieces per reel), or MGJ6T05150505MC-R13 (92 pieces per reel). 2. See ripple & noise test method. For full details go to 3. Between 75% and 100% rated output current. www.murata-ps.com/rohs All specications typical at TA=25C, nominal input voltage and rated output current unless otherwise specied. www.murata-ps.com/support KDC MGJ6C.E01 Page 1 of 10 3 Load Regulation (Typ) Rated Output Voltage 3 Load Regulation (Max) 2 Rated Output Current Ripple & Noise (Typ) 2 Ripple & Noise (Max) Output Power 3 Load Regulation (Typ) Rated Output Voltage 3 Load Regulation (Max) Rated Output Current 2 Ripple & Noise (Typ) Output Power 2 Ripple & Noise (Max)MGJ6 Series 5.2kVDC Isolated 6W Gate Drive SM DC/DC Converters SELECTION GUIDE (Continued) 1 MTTF Order Code V mA % pF kHrs MGJ6T05150505MC 5 1500 72 78 15 552 6821 MGJ6T12150505MC 12 600 77 81 15 633 7061 MGJ6T24150505MC 24 300 79 83 15 666 6774 INPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 5V input types 4.5 5 9 Voltage range 12V input types 9 12 18 V 24V input types 18 24 36 Turn on threshold MGJ6T05 4.1 Turn off threshold MGJ6T05 3.0 Turn on threshold MGJ6T12 8.1 Under voltage lock out V Turn off threshold MGJ6T12 7.5 Turn on threshold MGJ6T24 16.7 Turn off threshold MGJ6T24 16.3 5V input types 40 mA Input ripple current 12V input types 40 p-p 24V input types 24 OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Minimum load Below 10% load, 5V and 15V outputs are clamped to 6V and 16V respectively 10 % Voltage set point accuracy All output types 4 % Line regulation Low line to high line 2 % Peak deviation (50-100% & 100-50% load swing) 0.4 %Vout Transient response Settling time 0.1 ms ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Flash tested for 1 second 5200 Isolation test voltage VDC Qualication tested for 1 minute 5200 Resistance Viso = 1kVDC 100 G Continuous barrier withstand voltage Non-safety barrier application 3000 V GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Switching frequency 100 kHz TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Operation See derating graphs -40 105 Storage -50 125 C Product temperature rise above ambient 100% Load, Nom VIN, Still Air 25 ABSOLUTE MAXIMUM RATINGS Short-circuit protection Continuous Input voltage, MGJ6 5V input types 12V Input voltage, MGJ6 12V input types 20V Input voltage, MGJ6 24V input types 40V 1. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model at TA=25C with nominal input voltage at full load. www.murata-ps.com/support KDC MGJ6C.E01 Page 2 of 10 Nominal Input Voltage Input Current at Rated Load Efciency (Min) Efciency (Typ) Isolation Capacitance MIL 217 Telecordia