OKDL-T/60-W12-xxx-C 60A Digital PoL DC-DC Converter Series Typical units FEATURES PRODUCT OVERVIEW Input voltage range of 4.5 to 14Vdc The OKDL-T/60-W12 series are high efficiency, digital Apart from standard PoL performance and safety Point-of-Load (PoL) DC-DC power converters capable features like OVP, OCP, OTP, and UVLO, these 0.6 V - 1.8 V output voltage range digital converters have advanced features: digital of delivering 60A/108W. Available in a Land Grid High efficiency, typ. 94.9% at 5Vin, current sharing (full power, no derating), non-linear Array Package, these converters have a typical 1.8Vout half-load transient response, optimized dead time control, efficiency of 94.9%. PMBus compatibility allows LGA Package: 25.1 x 14.1 x 7.0 mm synchronization, and phase spreading. These monitoring and configuration of critical system-level (0.99 x 0.556 x 0.276 in) converters are ideal for use in telecommunications, performance requirements. networking, and distributed power applications. Configuration & Monitoring via PMBus Synchronization & phase spreading Current sharing, Voltage Tracking & Voltage margining Power Management via PMBus Applications MTBF 50 Mhrs Configurable soft-start/stop Distributed power architectures Non-Linear Response for reduction of Intermediate bus voltage applications Configurable output voltage (Vout) and voltage decoupling capacitor margins (Margin low and Margin high) Servers and storage applications Remote On/Off control & Power Good Configurable protection limits for OVP, input over Network equipment Output short-circuit, output over voltage, input under voltage, over current, on/off, voltage, & over temperature protection and temperature Certified to UL/IEC 60950-1 Status monitor Vout, Iout, Vin, Temp, Power Good, and On/Off PART NUMBER STRUCTURE OKD L - T / 60 W12 - xxx - CC Digital Non-isolated PoL RoHS Hazardous Substance Compliance C = RoHS-6 (does not claim EU RoHS exemption 7b lead in solder) L = Land Grid Array (LGA) Software Conguration Digits Trimmable Output (001 is positive turn-on logic) Voltage Range (002 is negative turn-on logic)* 0.6 - 1.8Vdc *Special quantity order is required Maximum Rated Output contact Murata Power Solutions for Input Voltage Range Current in Amps MOQ and lead times. 4.5-14Vdc www.murata-ps.com/support MDC OKDL-T/60-W12-xxx-C.A02 Page 1 of 73 OKDL-T/60-W12-xxx-C 60A Digital PoL DC-DC Converter Series Ordering Guide Model Number Package Type Output Input Range On/Off Logic OKDL-T/60-W12-001-C Land Grid Array 0.6-1.8V, 60A/108W 4.5V to 14V Positive Absolute Maximum Ratings Characteristics Min Typ Max Unit T Operating temperature (see Thermal Consideration section) -40 150 C P1 T Storage temperature (Ambient) -40 125 C S Input voltage (See Operating Information Section for input VI -0.3 16 V Signal I/O voltage CTRL, SA0, SA1, SALERT, SCL, SDA, VSET, SYNC, PG, VTRK -0.3 6.5 V Ground voltage -S, PREF, GND -0.3 0.3 V differential Analog pin voltage VO, +S -0.3 6.5 V General and Safety Conditions Min Typ Max Unit Safety Designed for UL/IEC/EN 60950 1 Calculated MTBF Telcordia SR-332, Issue 2 Method 1 50.15 Mhrs Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only functional operation of the device at these or any other conditions above those indicated in the Electrical Specification section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Configuration File This product is designed with a digital control circuit. The control circuit uses a configuration file which determines the functionality and performance of the product. The Electrical Specification table shows parameter values of functionality and performance with the Standard configuration, unless otherwise specified. The Standard configuration is designed to fit most application needs. Changes in Standard configuration might be required to optimize performance in specific application. Note that current sharing operation requires changed configuration. www.murata-ps.com/support MDC OKDL-T/60-W12-xxx-C.A02 Page 2 of 73