OKY-T/10 & T/16-W5 Series
www.murata-ps.com
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
PRODUCT OVERVIEW
The OKY-T/10 and -T/16 series are SMT non- ef cient Point of Load (POL) module features pro-
isolated Point-of-Load (POL) DC/DC power convert- grammable output voltage and On/Off control. An
ers for embedded applications. The module is fully optional Sequence/Tracking input allows controlled
compatible with Distributed-power Open Standards ramp-up and ramp-down outputs. The Sense input
Alliance (DOSA) industry-standard speci cations provides remote sense. These converters also
(www.dosapower.com). Applications include pow- include under voltage lock out (UVLO), output short
ering CPUs, datacom/telecom systems, program- circuit protection, over-current and over tempera-
TTypical unitypical unit
mable logic and mixed voltage systems. ture protections.
The wide input range is 2.4 to 5.5 Volts DC. Two These units are designed to meet all standard
maximum output currents are offered, 10 Amps UL/EN/IEC 60950-1 safety and FCC EMI/RFI
(T/10 models) or 16 Amps (T/16 models). Based emissions certi cations and RoHS-6 hazardous
on xed-frequency synchronous buck converter substance compliance.
switching topology, the high power conversion
FEATURES
Wide 2.4-5.5 VDC input range
Non-isolated output adjustable from 0.7525 to
3.63 Volts up to 16 Amps
DOSA-compatible SMT package
Contents Page
Drives 1000 F ceramic capacitive loads
Description, Connection Diagram, Photograph 1
Optional sequence/tracking operation Ordering Guide, Model Numbering 2
Mechanical Speci cations, Input/Output Pinout 3
Outstanding thermal performance and derating
Detailed Electrical Speci cations 4
Short circuit protection
Output Voltage Adjustment, Soldering Guidelines 5
On/Off control
Technical Notes 6
Performance Data and Oscillograms OKY2-T/16-W5 9
High ef ciency with no heatsink
Tape and Reel Information 16
Over temperature protection
Designed to meet UL/EN/IEC 60950-1 safety
approvals.
Simpli ed Block Diagram
+Vin +Vout
t4XJUDIJOH
F1
On/Off
Sense
Control
t' JMUFST
Controller
t$VSSFOU4FOTF
External
Trim
DC
Power
Reference and
Open = On
Source
Error Amplier
Closed = Off
(Positive
On/Off)
Common Common
Figure 1. OKY-T/10, -T/16
Sequence/Tracking (OKY2 only)
Note: Murata Power Solutions strongly recommends an external input fuse, F1.
See speci cations.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
MDC_OKY_T10T16.W5.A05 Page 1 of 16OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
Performance Speci cations Summary and Ordering Guide
ORDERING GUIDE
Output Input Package, C83
IOUT R/N (mVp-p) Regulation (Max.) VIN IIN, IIN, Ef ciency
VOUT (Amps Power Nom. Range no load full load
Model Number (Volts) max) (Watts) Max. Line Load (Volts) (Volts) (mA) (Amps) Min. Typ. Case Pinout
1.3x0.53x0.33
OKY-T/10-W5P-C 0.7525-3.63 10 33.0 20 0.2% 1% 5 2.4-5.5 80 7.58 92% 95% Pos. No P66
(33x13.5x8.3)
1.3x0.53x0.33
OKY-T/10-W5N-C 0.7525-3.63 10 33.0 20 0.2% 1% 5 2.4-5.5 80 7.58 92% 95% Neg. No P66
(33x13.5x8.3)
1.3x0.53x0.33
OKY2-T/10-W5P-C 0.7525-3.63 10 33.0 20 0.2% 1% 5 2.4-5.5 80 7.58 92% 95% Pos. Yes P66
(33x13.5x8.3)
1.3x0.53x0.33
OKY2-T/10-W5N-C 0.7525-3.63 10 33.0 20 0.2% 1% 5 2.4-5.5 80 7.58 92% 95% Neg. Yes P66
(33x13.5x8.3)
1.3x0.53x0.33
OKY-T/16-W5P-C 0.7525-3.63 16 52.8 50 0.2% 1% 5 2.4-5.5 80 11.12 92.5% 95% Pos. No P66
(33x13.5x8.3)
1.3x0.53x0.33
OKY-T/16-W5N-C 0.7525-3.63 16 52.8 50 0.2% 1% 5 2.4-5.5 80 11.12 92.5% 95% Neg. No P66
(33x13.5x8.3)
1.3x0.53x0.33
OKY2-T/16-W5P-C 0.7525-3.63 16 52.8 50 0.2% 1% 5 2.4-5.5 80 11.12 92.5% 95% Pos. Yes P66
(33x13.5x8.3)
1.3x0.53x0.33
OKY2-T/16-W5N-C 0.7525-3.63 16 52.8 50 0.2% 1% 5 2.4-5.5 80 11.12 92.5% 95% Neg. Yes P66
(33x13.5x8.3)
Efficiency is shown at Vout=1V.. Use adequate ground plane and copper thickness adjacent to the converter.
All specifications are at nominal line voltage, Vout=nominal (3.3V) and full load, +25 deg.C. unless otherwise Ripple and Noise (R/N) is shown at Vout=1V. See specs for details.
noted.
Dimensions are in inches (mm).
Output capacitors are 1 F ceramic and 10 F electrolytic in parallel. Input cap is 22 F. See detailed specifications.
I/O caps are necessary for our test equipment and may not be needed for your application.
PART NUMBER STRUCTURE
OK Y 2-/T 16 - W5 P - C
Okami Non-isolated PoL RoHS Hazardous
Substance Compliance
C = RoHS-6 (does not claim EU RoHS exemption 7blead in solder)
Surface Mount
Sequence/tracking
On/Off Polarity
Blank=Not installed, delete seq/track contact
P = Positive Polarity
2=Installed, add seq/track contact
N = Negative Polarity
Trimmable Output
Voltage Range
Input Voltage Range
W5 Models = 0.7525-3.63V
W5 = 2.4-5.5V
Maximum Rated Output
Current in Amps
www.murata-ps.com/support
MDC_OKY_T10T16.W5.A05 Page 2 of 16
On/Off
Polarity
Sequence/
Tracking