ULQ Models www.murata-ps.com Single Output, Low-Profile, Quarter-Brick 8-25 Amp Isolated DC-DC Converters Typical units Features For applications requiring improved electrical and thermal perfomance at reduced cost DATEL s new ULQ SeriesQuarter-Bric DC-DC Converters suit perfectly. They measure just 1.45 x 2.30 x Standard quarter-brick package/pinout 0.35 inches (36.8 x 58.4 x 8.9mm) and fit the industry-standard footprint. You can alsopick-and- in through-hole or SMT version plac the ULQ-SMT version optimizing your automated SMT process. Low cost Low profile, 0.35 (8.9mm) From an 18-36V or 36-75V input, ULQ s deliver outputs of 1.2, 1.5, 1.8, or 2V fully rated at 15 or 24V and 48V nominal inputs 25A, 2.5 or 3.3V at 15 or 20A, 5V at 15A and 12V at 8-10A. They Output current: 8 to 25 Amps employ an interleaved, synchronous-rectifier topology that exploits 100% of their duty cycle. They simultaneously achieve ultra-high efficiency (to 91%), tight line/load regulation (0.125/0.25%), low Output voltages: 1.2/1.5/1.8/2/2.5/3.3/5/12V noise (25-70mVp-p), and quick step response (200sec). Interleaved synchronous-rectifier topology A state of the art, single-board, open-frame design with reduced component count, high Ultra high efficiency efficiency, low-on-resistance FET s, and planar magnetics embedded in heavy-copper pc boards all No output reverse conduction contribute to impressive thermal derating. Outstanding thermal performance The ULQ s feature set includes high isolation (2250Vdc), input pi filters, input undervoltage shut - On/off control, trim & sense functions down, output overvoltage protection, current limiting, short-circuit protection and thermal shutdown. The standard footprint carries on/off control (positive or negative logic), output trim (+10/20%) and Fully isolated, 2250Vdc (BASIC) output sense functions. Output overvoltage protection All ULQ quarter-bricks are designed to meet the BASIC-insulation requirements of UL/EN/ Fully I/O protected Thermal shutdown IEC60950 and they will carry the CE mark. Safety certifications, EMC compliance testing and qualifi - UL/EN/IEC60950 safety approvals cation testing (including HALT) are currently in progress. Contact DATEL for latest updates. Qual/HALT/EMI tested +SENSE (7) +VIN +VOUT (1) (8) SWITCH CONTROL VOUT (4) VIN (3) SENSE (5) PWM OPTO REFERENCE & CONTROLLER ISOLATION ERROR AMP VOUT TRIM (6) INPUT UNDERVOLTAGE, INPUT OVERVOLTAGE, AND OUTPUT OVERVOLTAGE COMPARATORS * Can be ordered with positive (standard) or negative (optional) polarity. REMOTE ON/OFF CONTROL* (2) Figure 1. Simplified Schematic Typical topology is shown. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support Typical topology is shown MDC ULQ-15A.E05 Page 1 of 17ULQ Models Single Output, Low-Profile, Quarter-Brick 8-25 Amp Isolated DC-DC Converters Performance Specifications and Ordering Guide ORDERING GUIDE Output Input Package Efficiency Regulation (Max.) (Case, Root Model Vout Iout R/N (mVp-p) Vin Nom. Range IIN Pinout) (Volts) (Amps) Typ. Max. Line (Volts) (Volts) (mA/A) Min. Typ. Load ULQ-1.5/15-D48N-C 1.5 15 25 50 0.125% 0.25% 48 36-75 35/0.5 87% 89% C37, P32 ULQ-1.5/25-D24P-C 1.5 25 50 100 0.125% 0.25% 24 18-36 50/1.8 85.5% 87.5% C37, P32 ULQ-1.5/25-D48N-C 1.5 25 45 75 0.125% 0.25% 48 36-75 30/0.9 85% 87% C37, P32 ULQ-1.8/15-D48N-C 1.8 15 25 50 0.125% 0.25% 48 36-75 35/0.6 87.5% 89% C37, P32 ULQ-1.8/25-D24P-C 1.8 25 50 100 0.125% 0.25% 24 18-36 90/2.2 85.5% 87.5% C37, P32 ULQ-1.8/25-D48N-C 1.8 25 70 100 0.25% 0.25% 48 36-75 45/1.1 85.5% 87.5% C37, P32 ULQ-2/15-D48N-C 2 15 25 50 0.125% 0.25% 48 36-75 45/0.6 87% 89% C37, P32 ULQ-2/25-D24P-C 2 25 50 100 0.125% 0.25% 24 18-36 50/2.4 86% 88% C37, P32 ULQ-2/25-D48N-C 2 25 70 100 0.25% 0.25% 48 36-75 50/1.2 86% 88% C37, P32 ULQ-2.5/15-D48N-C 2.5 15 35 55 0.125% 0.25% 48 36-75 45/0.9 88% 89.5% C37/C40, P32 ULQ-3.3/15-D48NM-C 3.3 15 45 75 0.125% 0.25% 48 36-75 45/1.2 88.5% 90.5% C37/C40, P32 ULQ-3.3/20-D24PM-C 3.3 20 50 100 0.125% 0.25% 24 18-36 80/3.1 87.5% 89.5% C37/C40, P32 ULQ-3.3/20-D48NM-C 3.3 20 45 75 0.125% 0.25% 48 36-75 45/1.6 88% 90% C37/C40, P32 ULQ-5/15-D24PM-C 5 15 50 100 0.25% 0.25% 24 18-36 50/3.5 89% 91% C37/C40, P32 ULQ-5/15-D48NM-C 5 15 50 100 0.1% 0.4% 48 36-75 50/1.7 89% 91% C37/C40, P32 ULQ-12/8-D24PM-C 12 8 95 130 0.25% 0.25% 24 18-36 90/4.4 89% 90.5% C37/C40, P32 ULQ-12/10-D48NM-C 12 10 90 130 0.25% 0.25% 48 36-75 80/2.9 88% 90% C37/C40, P32 ULQ-3.3/15-D48N-C 3.3 15 45 75 0.125% 0.25% 48 36-75 45/1.2 88.5% 90.5% C37/C40, P32 ULQ-3.3/20-D24P-C 3.3 20 50 100 0.125% 0.25% 24 18-36 80/3.1 87.5% 89.5% C37/C40, P32 ULQ-3.3/20-D48N-C 3.3 20 45 75 0.125% 0.25% 48 36-75 45/1.6 88% 90% C37/C40, P32 ULQ-5/15-D24P-C 5 15 50 100 0.25% 0.25% 24 18-36 50/3.5 89% 91% C37/C40, P32 ULQ-5/15-D48N-C 5 15 50 100 0.1% 0.4% 48 36-75 50/1.7 89% 91% C37/C40, P32 ULQ-12/8-D24P-C 12 8 95 130 0.25% 0.25% 24 18-36 90/4.4 89% 90.5% C37/C40, P32 ULQ-12/10-D48N-C 12 10 90 130 0.25% 0.25% 48 36-75 80/2.9 88% 90% C37/C40, P32 Typical at TA = +25C under nominal line voltage and full-load conditions. All models are Nominal line voltage, no load/full load condition. specified with an external 1F multi-layer ceramic and 10F capacitors across their output pins. Please refer to the Part Number Structure when ordering. Ripple/Noise (R/N) measured over a 20MHz bandwidth. Not all model number combinations are available. Consult Murata Power Solutions. Devices have no minimum-load requirements and will regulate under no-load conditions. Regulation specifications describe the output voltage deviation as the line voltage or load is varied from its nominal/midpoint value to either extreme. (Load step = 50%.) ULQ-12/8-D24N-C ULQ-12/8-D24PL1-C ULQ-3.3/20-D24N-C ULQ-3.3/20-D24PL2-C ULQ-12/8-D24NL1-C ULQ-3.3/15-D48N-C ULQ-3.3/20-D24NL2-C ULQ-5/15-D48N-C ULQ-12/8-D24NL2-C ULQ-3.3/15-D48P-C ULQ-3.3/20-D24P-C ULQ-5/15-D48P-C ULQ-12/8-D24P-C ULQ-3.3/15-D48PL1-C ULQ-3.3/20-D24PL1-C ULQ-5/15-D48PL2-C ULQ-12/10-D48NL1-C ULQ-12/10-D48NL2-C ULQ-12/10-D48PL2-C PART NUMBER STR UCTURE - C U LQ - 3.3 / 20 D48 N M Lx - Output RoHS-6 compliant Configuration Pin Length Option Quarter-Brick Package Surface-Mount Package (see list above) Nominal Output Voltage Maximum Rated Output Remote On/Off Control Logic Input Voltage Range See page 16 for complete Part Number Structure. www.murata-ps.com/support MDC ULQ-15A.E05 Page 2 of 17