DC Voltmeter, Ammeter, Indicator/ Controller 1 8 DIN Q2000-AB Series U 1,999 or 9,999 Count Display Span U 200 mV to 200 V or 100 mV to 100 V Ranges U 20 A to 2 A or 10 A to 1 A ranges U 1 or 0.1 mV/Count Analog Output U Front-Panel Accessible Adjustments Q2000-AVR4 Meter shown smaller U LED or LCD Display than actual size. U Automatic Polarity U Display Hold and Test U Screw-Terminal Barrier Strip The Q2/9000A and Q2/9000B are a high-quality Control Output Options 1,999 or 9,999 count DC voltmeter and ammeter, Additional outputs can be provided by a horizontal respectively. The base meters are digital indicators for upper board. Available options include single-setpoint use in electrically-noisy industrial environments. With control with one 10 A relay, dual-setpoint control the addition of analog and control outputs, these meters with two 10 A relays, 4 to 20 mA proportional control can provide two-wire current-loop signals to a central (source or sink), time-proportional 2 A solid-state 1 control room and provide local alarm or control. A 8 relay control, and isolated, parallel BCD output. DIN case with screw terminals for signal and power is standard. A wide range of options are available. Power and Display Options Specifications Six types of power supplies are available: 120 Vac, Input Configuration 240 Vac, 24 Vac, 5 Vdc, isolated 9 to 32 Vdc and isolated 26 to 56 Vdc. An LED display is standard, Configuration: Bipolar, single-ended an LCD display is optional and is recommended for Polarity: Automatic viewing in bright ambient light. A NEMA 4 (IP65) Span Adjustment: 4% splash-proof lens cover is available. Conversion Signal input and power connections are made via a Technique: Auto-zero, dual slope, average value rear barrier terminal strip. The motherboard rear edge Signal Integration Period: 100 ms, nominal connector provides access to hold and test, polarity, Reading Rate: 2.5/s, nominal clock, and the standard analog output and optional Display analog outputs. Decimal point positions can be selected by jumpers. LED: Red, 14.2 mm (0.56 ), 7-segment LCD: 12.7 mm (0.50 ), 7-segment Analog Output Options A 1 mV/count (2V full-scale) or 0.1 mV/count Power (1V fullscale) analog output is standard and is AC Voltages: 120, 240 or 24 Vac 10%/-15% ideal for driving a strip-chart recorder. An additional AC Frequency: 49 to 440 Hz analog output can be provided by an optional vertical DC Voltages: plug-in board. Available output signals are 0 to 5 Vdc, 9 to 32 Vdc, isolated to 300 Vp 0 to 10 Vdc, 0 to 1 mA (source or sink) and 4 to 20 mA 26 to 56 Vdc,isolated to 300 Vp (source or sink). The top and bottom of each output 5 Vdc 5%, non-isolated range can be scaled to fit a user-selected display span. Power Consumption: 8 W maximum 1DC Voltage Inputs A Series Common Mode Voltage: 1500 Vp test (354 Vp per IEC spacing) Code Q2000 Q9000 Input Q2000 Q9000 ACC Rejection (DC to 60 Hz): 120 dB * Range Range Imped Res Res 25C NMR 50/60 Hz: 75 dB (Q2), 130 dB (Q9) AVR1 199.9 mV 99.99 mV 1 G 0.1 mV 0.01 mV 0.05% Environmental of Rdg AVR2 1.999 V 999.9 mV 1 mV 0.1 mV 1 M 1 (Q2) Operating Temperature: 0 to 60C (32 to 140F) AVR3 19.99 V 9.999 V 1 M 10 mV 1 mV 2 (Q9) Storage Temperature: -40 to 85C (-40 to 185F) counts AVR4 199.9 V 99.99 V 1 M 100 mV 10 mV Humidity: 95% RH, non-condensing 40C (104F) Mechanical DC Currents Inputs B Series Bezel: 96 W x 48 H x 8 mm D (3.78 x 1.89 x 0.31 ) Code Q2000 Q9000 Input Q2000 Q9000 ACC * Range Range Imped Res Res 25C Depth Behind Bezel: 139.8 mm (5.50 ) BCR1 19.99 A 9.999 A 0.01 A 1 nA Panel Cutout: 92 W x 45 mm H (3.62 x 1.77 ) 10 k Weight: 17 oz (480 g) BCR2 199.9 A 99.99 A 1 k 0.1 A 10 nA 0.05% of Case Material: 94V-0 UL-rated polycarbonate Rdg BCR3 1.999 mA 999.9 A 100 1 A 100 nA 1 (Q2) BCR4 19.99 mA 9.999 mA 10 10 A 1 A 2 (Q9) counts BCR5 199.9 mA 99.99 mA 100 A 10 A 1 BCR6 1.999 A 999.9 mA 0.1 1 mA 100 A Ordering Example: Q2000-BCR3, LED 120 Vac, 1 A/count, DC current between -1.999 mA and 1.999 mA. To Order Visit newportUS.com/q2000a b for Pricing and Details Model No. Description Q2 3-Digit for 1999 Count Q9 4-Digit for 9999 Count 0 0 0 -X A. Power and Display 0 LED 120 Vac (50/60 Hz) 1 LCD 120 Vac (50/60 Hz) (Q2000 only) 2 LED 240 Vac (50/60 Hz) 3 LCD 240 Vac (50/60 Hz) (Q2000 only) 4 LED 9 to 32 Vdc, isolated 5 LCD 9 to 32 Vdc, isolated (Q2000 only) 6 LED 5 Vdc 7 LCD 5 Vdc (Q2000 only) 8 LED 24 Vac 9 LCD 24 Vac (Q2000 only) A LED 26 to 56 Vdc, isolated B LCD 26 to 56 Vdc, isolated (Q2000 only) B. Analog Outputs 0 1 mV/count (Q2000) or 0.1 mV (Q9000) (supplied on all units) 1 0 to 5 Vdc 2 0 to 10 Vdc 3 0 to 1 mA (internally driven) 4 4 to 20 mA (internally driven) 5 4 to 20 mA (externally driven) 6 4 to 20 mA (isolated) C. Control Outputs 0 None 1 Dual setpoint, 10 A relay (SPDT) 2 Proportional 4 to 20 mA 3 Proportional/time proportioning, 2 A relay 4 Parallel BCD, isolated 5 Single setpoint, 10 A relay (SPDT) D. Signal Conditioner Inputs -A(*) DC voltage -B(*) DC current Additional Options ,G Green LED display ,BL Lens without Newport logo in lieu of standard lens * Refer to chart above for code options. 1 Ordering Example: Q2002-AVR2, 3 2 digit, red LED, 120 Vac power, 1mv/count, DC voltage between -1.999 V and 1.999 V. 2