Product Information

RNPP-302

RNPP-302 electronic component of Novatek

Datasheet
Module: voltage monitoring relay; DIN; SPDT; OUT1:250VAC/8A

Manufacturer: Novatek
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 71.058 ea
Line Total: USD 71.06

3 - Global Stock
Ships to you between
Fri. 17 May to Thu. 23 May
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
3 - WHS 1


Ships to you between Fri. 17 May to Thu. 23 May

MOQ : 1
Multiples : 1

Stock Image

RNPP-302
Novatek

1 : USD 71.058
5 : USD 68.445

     
Manufacturer
Product Category
Mounting Type
Kind Of Display Used
Controlled Parameter
Controlled Parameter Range
Kind Of Output 1
Ip Rating
Power Supply
Leads
Additional Functions
Output 1 Electrical Parameters
Type Of Module
Contact Actuation Delay
Body Dimensions
Operating Temperature
Voltage Between Phases For Three Phase System
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
RNPP-311M electronic component of Novatek RNPP-311M

Module: voltage monitoring relay; DIN; SPDT; 0÷600s; 35x93x65mm
Stock : 8

TK-415 electronic component of Novatek TK-415

Timer; Range:0,1s÷99h; relay SPST x15; 85÷270VAC; DIN
Stock : 0

UBZ-302 electronic component of Novatek UBZ-302

Module: monitoring relay; asynchronous motors; SPDT; 3x400VAC
Stock : 0

RNPP-311.1 electronic component of Novatek RNPP-311.1

Module: voltage monitoring relay; DIN; SPDT; OUT1:250VAC/5A
Stock : 0

RNPP-312 electronic component of Novatek RNPP-312

Module: voltage monitoring relay; DIN; SPDT; OUT1:250VAC/5A
Stock : 0

TR-12 electronic component of Novatek TR-12

Module: regulator; digital; temperature; Temp: -10÷45°C; 230VAC
Stock : 0

TR-100 electronic component of Novatek TR-100

Module: regulator; temperature; 24÷260VAC; DIN; 24÷260VDC
Stock : 4

TR-100M electronic component of Novatek TR-100M

Module: regulator; temperature; 24÷265VAC; on panel; 24÷265VDC
Stock : 1

UBZ-304 electronic component of Novatek UBZ-304

Module: monitoring relay; asynchronous motors; SPDT; 3x400VAC
Stock : 1

TR-101 electronic component of Novatek TR-101

Module: regulator; temperature; 24÷260VAC; DIN; 24÷260VDC
Stock : 0

Image Description
K70B881 electronic component of TE Connectivity K70B881

High Voltage Relays
Stock : 0

K81A335 electronic component of TE Connectivity K81A335

General Purpose Relays RELAY VACUUM SPST-NO
Stock : 9

K81A345 electronic component of TE Connectivity K81A345

Contactors - Electromechanical RELAY VACUUM SPST-NO
Stock : 17

K81AA57 electronic component of TE Connectivity K81AA57

General Purpose Relays RELAY VACUUM SPST-NO
Stock : 0

K81B-09 electronic component of TE Connectivity K81B-09

General Purpose Relays K81B-09
Stock : 5

K81B335 electronic component of TE Connectivity K81B335

K81B335=RELAY, VACUUM, SPST-NC
Stock : 217

K81C-02 electronic component of TE Connectivity K81C-02

General Purpose Relays RELAY VACUUM SPDT
Stock : 25

K81C235 electronic component of TE Connectivity K81C235

General Purpose Relays 1FormA SPST 12V 10 A
Stock : 17

K8AK-PA2 electronic component of Omron K8AK-PA2

Module: voltage monitoring relay; DIN; SPDT; 0.1÷30s; IP20
Stock : 0

K8AK-PH1 electronic component of Omron K8AK-PH1

Module: voltage monitoring relay; phase sequence, phase failure
Stock : 18

NOVATEK-ELECTRO LTD Intellectual Industrial Electronics RNPP-302 MULTIFUNCTIONAL THREE PHASE VOLTAGE MONITORING RELAY OPERATING MANUAL Quality control system on the production complies with requirements ISO 9001:2008 Review the Operating manual before using the unit. Store the unit in the operating environment for 2 hours before switching to the mains. Do not use abrasives or organic compounds for cleaning (spirit, gasoline, solvents, etc.). NEVER ATTEMPT TO REMOVE AND REPAIR THE UNIT. Some of the unit components may be live. NEVER ATTEMPT TO OPEN AND REPAIR THE PROTECTED EQUIPMENT, IF SWITCHED TO THE UNIT SOCKET. Do not allow any water on the contacts of the connecting blocks or inner elements of the unit. Do not use the unit in corrosive environments with the air containing acids, alkalis, oils, etc. www.novatek-electro.com - 2 - APPLICATION Universal Three phase voltage monitoring relay RNPP-302 (hereinafter RNPP-302) is designed for the permanent voltage monitoring, control and protection of the equipment with rated voltage parameters of 220/380V and 230/400V or 240/415V at rated frequency of 50Hz. RNPP-302 protects the power load from the following alarm situations and power faults: - over/under voltage, voltage surges and fluctuations, - phase loss, - phase coincidence, - wrong phase sequence, - phase imbalance in the AC power circuits - control over the full phase switching of the contactor - remote control input signal to operate with the power load as per requirement The RNPP-302 operates with the magnetic coil of the external contactor which in its turn operates with the power load. The RNPP-302 constantly checks (before and after turning on) the condition of the power contacts of magnetic contactor and detects the stuck together and burned contacts. When the power parameters return back to normal after the interruption or when the reason of the tripping is eliminated the RNPP-302 performs automatic reclosing and thus restart the equipment. It does so following a time delay (0-600 sec), set previously by the user. RNPP-302 relay may work in four independent modes: 1. phase loss monitoring mode without voltage level control (parameter = 0) 2. minimum voltage monitoring mode (parameter = 1) 3. maximum voltage monitoring mode (parameter = 2) 4. symmetrical min/max voltage monitoring mode (parameter = 3) The LED display of the RNPP-302 indicates: - Acting value (true RMS) of the phase voltage or alternatively line voltage depending on mode of operation - Voltage fault in mains power supply and the type of the interruption - State of output relay contacts (OPEN/CLOSE) NOTICE. The term rated voltage used in this device manual means that the input voltage corresponds all settings and parameters adjusted by user (see Table 2). Time countdown of the autoreclosing delay starts from the moment of the fault detection (not from the moment when the power parameters recovered to their corresponding rated values) During the countdown of the autoreclosing time delay LED indicator REL will blink in case of the normal power parameters. 1. MAIN FEATURES Digital input to turn ON/OFF the RNPP-302 remotely Changeover relay output (8A 250V at cos =1) for the operation by the magnetic contactor to commutate any desired power load Normally Opened relay contact (8A 250V at cos =1) for the signalization Measurement accuracy for tripping thresholds: not exceed 3V Rated phase/line voltage 220/380V (230/400V or 240/415V) The adjustable ranges for minimal voltage maximal voltage tripping phase imbalance time delays for the protection tripping automatic restart (autoreclosing) time and other adjustable parameters are shown in the Table 2. Rated power consumption: not exceed 5 W Protection degree of the enclosure case: IP40 Protection degree of terminal block: IP20 Operational temperature range, C: from - 35 to +55 Storage temperature conditions, C: from - 45 to +75 Weight not more than 0,3 kg Mounting: fit the standard 35 mm DIN-rail Mounting position: arbitrary - as per requirement Dimensions and control buttons are shown on Figure 1. RNPP-302 complies with requirements: IEC 60947-1:2004, D EC 60947-6-2:1992, DT CISPR 11:2004, IDT IEC 61000-4-2:2001, IDT. RNPP-302 NOVATEK-ELECTRO

Tariff Desc

8536.49.00 TC 17103979 RELAYS PRINTED CIRCUIT BOARD

8536.41 TC 8909066 having a continuous contact rating of NOT less than 3A and body dimensions NOT exceeding 40mm x 30mm x 27mm

8536.49.00 TC 9613322 low profile, OTHER THAN reed relays, being EITHER of the following
a) height NOT exceeding 21.24mm
b) height NOT exceeding 35mm and having a continuous current rating NOT less than 8A AC

8536.49 TC 8906734 RELAYS, having ALL of the following
a) one, two or three contacts
b) maximum continuous contact current rating of NOT less than 15A
c) maximum contact voltage rating of NOT less than 380V
d) maximum switched power rating of NOT less than 4000VA

8536.49.00 TC 1122469 RELAYS, having an operating voltage NOT exceeding 250 volts having ANY of the following:
a) spring loaded terminals
b) plug-in screw terminals
c) wire connected terminals

8536.41 TC 8534635 RELAYS, cradle, having ALL of the following
a) maximum switching current NOT exceeding 5A AC or DC
b) switching voltage NOT exceeding 250V AC or DC
c) body dimensions NOT exceeding 31mm x 36mm x 19mm

8536.49 TC 8633667 RELAYS vacuum, hermetically sealed

8536.41.00 TC 19144923 RELAYS SWITCH AMPLIFIER, having a supply voltage NOT greater than 40v

8536.49 8633669 RELAYS, thermal overload, having ALL of the following characteristics
a) trip time NOT exceeding 5 s at 6 times full load current
b) manual reset
c) maximum current 50A

8536.49 TC 8633636 RELAYS, power appliance, 15A, having EITHER 2 contacts or 3 contacts

8536.49 TC 8532678 CONTACTORS, having BOTH of the following
a) normally closed main poles
b) DC rated current 9 A or greater

8536.49.00 TC 1312158 CONTACTORS, single OR multi-pole, for a voltage NOT exceeding 1000V

8536.49.00 solid state having an operating voltage NOT exceeding 600VAC or 300VDC but NOT including protective monitoring TC 9320885

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted