GL66 SERIES MILD STEEL HINGED COVER WALL-MOUNT ENCLOSURES Hoffman mild steel wall-mount enclosures from Pentair are designed to house and protect electrical and electronic components in industrial environments. An ergonomic and aesthetic styling together with an attractive durable light-gray finish make this solution an excellent choice when style and functionality are important. All types of wall-mount enclosure have an outward formed flange to prevent contaminants from entering the enclosure. Wide range of standard catalogue items makes this solution available fast. INDUSTRY STANDARDS SPECIFICATIONS Solid hinged cover models Mild steel solution constructed from doors thickness 1,2 mm 1,5 mm or 1,8 mm and body thickness 1,2 mm UL 508A listed Type 3,4,12 File No. E61997 or 1,5 mm cUL Listed per CSA C22.2 No.94 Type 3,4,12 90 degree external formed body flange File No. E61997 Seamless foam-in-place gasket NEMA/EEMAC Type 4 and 12 Reversible right to left side hinged door with simple, CSA, File No. 42186: Type 4, 12, 13 easy-to remove and install hinge pins IEC 60529, IP66 IEC/EN62262 IK9 Door opens 210 degrees Quarter-turn latch(es) with 3 mm double-bit insert Finish RAL 7035 textured light-gray polyester powder paint. Grounding studs system Conductive panel available optionally integrated or as an accessory Solution with gland plate Furnished hardware kit includes solid washers for wall-mounting, key hole plugs Weatherproof paint available on request Installation instruction DESIGN WITH CONFIDENCE EQUIPMENT PROTECTION HINGED COVER WALL-MOUNT ENCLOSURES 1GL66 WALL-MOUNT ENCLOSURES, STANDARD PRODUCTS, HINGED COVER MODELS WITHOUT MOUNTING PANEL STANDARD PRODUCT Gland Door Body Conductive Solution with H W D Plate Qty & thickness Thickness mounting mouting panel Item Number Description mm mm mm type mm mm panel integrated M300300210GE GL66 MS HC 300H300W210D 300 300 210 A 1.2 1.2 M300P300GE M300300210GPE M300400210GE GL66 MS HC 300H400W210D 300 400 210 B 1.2 1.2 M300P400GE M300400210GPE M400400210GE GL66 MS HC 400H400W210D 400 400 210 A 1.2 1.2 M400P400GE M400400210GPE M400600210GE GL66 MS HC 400H600W210D 400 600 210 B 1.2 1.2 M400P600GE M400600210GPE M400600350GE GL66 MS HC 400H600W350D 400 600 350 C 1.2 1.2 M400P600GE M400600350GPE M400300210GE GL66 MS HC 400H300W210D 400 300 210 C 1.2 1.2 M400P300GE M400300210GPE M500400210GE GL66 MS HC 500H400W210D 500 400 210 B 1.2 1.2 M500P400GE M500400210GPE M500500210GE GL66 MS HC 500H500W210D 500 500 210 C 1.2 1.2 M500P500GE M500500210GPE M500500300GE GL66 MS HC 500H500W300D 500 500 300 C 1.2 1.2 M500P500GE M500500300GPE M600400210GE GL66 MS HC 600H400W210D 600 400 210 B 1.2 1.2 M600P400GE M600400210GPE M600400350GE GL66 MS HC 600H400W350D 600 400 350 B 1.2 1.2 M600P400GE M600400350GPE M600600210GE GL66 MS HC 600H600W210D 600 600 210 C 1.5 1.5 M600P600GE M600600210GPE M600600250GE GL66 MS HC 600H600W250D 600 600 250 C 1.5 1.5 M600P600GE M600600250GPE M600600350GE GL66 MS HC 600H600W350D 600 600 350 C 1.5 1.5 M600P600GE M600600350GPE M600800300GE GL66 MS HC 600H800W300D 600 800 300 2xB 1.8 1.5 M600P800GE M600800300GPE M700500250GE GL66 MS HC 700H500W250D 700 500 250 C 1.5 1.5 M700P500GE M700500250GPE M800600210GE GL66 MS HC 800H600W210D 800 600 210 C 1.8 1.5 M800P600GE M800600210GPE M800600350GE GL66 MS HC 800H600W350D 800 600 350 C 1.8 1.5 M800P600GE M800600350GPE M800800210GE GL66 MS HC 800H800W210D 800 800 210 2xB 1.8 1.5 M800P800GE M800800210GPE M800800300GE GL66 MS HC 800H800W300D 800 800 300 2xB 1.8 1.5 M800P800GE M800800300GPE M800400300GE GL66 MS HC 800H400W300D 800 400 300 B 1.5 1.5 M800P400GE M800400300GPE M800600250GE GL66 MS HC 800H600W250D 800 600 250 C 1.8 1.5 M800P600GE M800600250GPE M800600400GE GL66 MS HC 800H600W400D 800 600 400 C 1.8 1.5 M800P600GE M800600400GPE M800800225GE GL66 MS HC 800H800W225D 800 800 225 2xB 1.8 1.5 M800P800GE M800800225GPE M1000600250GE GL66 MS HC 1000H600W250D 1000 600 250 C 1.8 1.5 M1000P600GE M1000600250GPE M1000600400GE GL66 MS HC 1000H600W400D 1000 600 400 C 1.8 1.5 M1000P600GE M1000600400GPE M1000800300GE GL66 MS HC 1000H800W300D 1000 800 300 2xB 1.8 1.5 M1000P800GE M1000800300GPE M1000800400GE GL66 MS HC 1000H800W400D 1000 800 400 2xB 1.8 1.5 M1000P800GE M1000800400GPE 8 7 6 534 21 F Q E W D W W-41 19.8 19.1 W-38,2 M8 x 1,25 20,5 (BODY OPENING) Y 12.7 D 22.5 B OMIT MIDDLE C STUDS IF H<700 B Y 13.50 12.20 D-33.4 A Data subject to change without notice Date: 5/28/2014 Dimensioning in mm Pentair Equipment Protection Products Company Part no.: 62512-029 DZI Pentair Poland Sp.z o.o. ul. Strefowa 10 Polska 58-200 Dzieroniw 8 7 6 5 4 3 21 EQUIPMENT PROTECTION HINGED COVER WALL-MOUNT ENCLOSURES 2 Kopiowanie, dystrybucja i wykorzystywanie niniejszego dokumentu, jak rwnie przekazywanie The reproduction, distribution and utilization of this document as well as the communication of its jego treci osobom trzecim bez pisemnej zgody jest zabronione pod grob wypaty contents to others without express authorization is prohibited. Oenders will be held liable for the odszkodowania. W przypadku przyznania patentu, wzoru uytkowego lub projektu, wszelkie payment of damages. All rights reserved in the event of the grant of a patent, utility model or prawa bd zastrzeone. design. H H-41 20.5 (BODY OPENING) P H H-38,2 19.1 22.5 A 13.50