Sealed e nclo Sure c ooling Air Conditioners SPec Tracool narro W indoor /ou Tdoor Fea Ture S Narrow design accommodates 12-in. (300-mm) deep cabinets E nergy efficient reciprocating compressor on N28 models Energy efficient rotary compressor on N36 and N43 models R407c and R134a earth-friendly refrigerants Models for 115, 230 and 400/460 3-phase VAC power input UL Listed to save customers time and money with agency approvals O utdoor model operating temperature range from -40 F/-40 C to 131 F/55 C (125 F/52 C on N28 Series) A ttractive industrial design with minimal use of visible fasteners R eliable mechanical thermostat on enclosure side of the unit indoor Air Conditioner models include digital display on ambient side G alvanized sheet-metal cover for rugged factory and outdoor environments Easy-mount flanges for simple installation C ut-out adapter options for enclosures with GENESIS air conditioners enable users to easily transition to the new unit Dust-resistant condenser coil allows the unit to be run filterless in most applications Cleanable, reusable aluminum mesh filter protects coils for maximum cooling performance Mounting hardware, gaskets and user manual furnished with the unit Every unit functionally tested before shipping Standard Indoor Air Conditioner models also include: NN4343 NN3636 NN2828 - Active condensate management with heater strip - Power-off relay for door switch and other system 11000 BTU/Hr. 6000/8000 BTU/Hr. 4000 BTU/Hr. requirements 3223 Watt 1758/2344 Watt 1172 Watt - Malfunction switch S tandard Outdoor Air Conditioner models also include: - Telcordia GR-487 capable - Corrosion-resistant components - Malfunction switch indu STr Y STandard S - Compressor heater - Head pressure control UL/cUL Listed Type 12, 3R, 4 4X optional File No. SA6453 - 1300 W enclosure heater CE SPeci Fica Tion S IP 56 Internal Loop Nom inal cooling capacity: IP 34 on External Loop N28 4000 BTU/Hr. (1172 W) Telcordia GR-487 capable (Outdoor) N36 6000 & 8000 BTU/Hr. (1758 and 2344 W) N43 11000 BTU/Hr. (3223 W) a PPlica Tion O utdoor model operating temperature range from -40 F/-40 C to I n du s t r ial au t o m a t io n 131 F/55 C (125 F/52 C on N28 Series) W aste water treatment systems P ackage handling equipment Fini Sh Security and defense systems RAL 7035 light-gray, semi-textured powder-coat paint O ther colors and textures available no TeS Visit www.PentairProtect.com to download 2D and 3D CAD drawings into the overall design of your electrical system. 1 Thermal managemen T SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Spec-00732 MSealed e nclo Sure c ooling Air Conditioners Performance Data n 28 4000 BTu /h r. (1172 Watt) caTalog numBer Indoor Model N280416G050 N280426G050 N280446G050 Indoor Model Stainless Steel Type 4X N280416G051 N280426G051 N280446G051 Indoor Model with Remote Access Control* N280416G060 N280426G060 N280446G060 Outdoor Model without Heat Pkg. N280416G100 N280426G100 N280446G100 Outdoor Model without Heat Pkg. Stainless Steel Type 4X N280416G102 N280426G102 N280446G102 Outdoor Model with Heat Pkg. N280416G150 N280426G150 Outdoor Model with Heat Pkg. Stainless Steel Type 4X N280416G151 N280426G151 cooling PerFormance nominal: BTus/hr. 3800 / 4000 3800 / 4000 4000 Watts 1114 / 1172 1114 / 1172 1172 At 125 F / 125 F (50 C / 50 C): BTU/Hr. (50 / 60 Hz) 3940 / 4104 4269 / 4703 4703 Watts (50 / 60 Hz) 1150 / 1000 1250 / 1378 1378 At 95 F / 95 F (35 C / 35 C): BTU/Hr. (50 /60 Hz) 3754 / 4011 3700 / 4291 4291 Watts (50 / 60 Hz) 1100 / 1175 1086 / 1257 1257 Refrigerant R134a R134a R134a Refrigerant Charge (ounces/grams) 10 / 283 11 / 312 11 / 312 Operating Temperature Range: Maximum (F / C) 125/52 125/52 125/52 Minimum (F / C) -40/-40 -40/-40 -40/-40 Air Flow at 0 Static Pressure: 3 138 / 234 N/A N/A Internal loop 50 Hz (CFM / M /Hr) 3 268 / 455 N/A N/A External loop 50 Hz (CFM / M /Hr) 3 143 / 362 143 / 243 143 / 243 Internal loop 60 Hz (CFM / M /Hr) 3 288 / 728 288 / 489 288 / 489 External loop 60 Hz (CFM / M /Hr) Max. Heater W (Outdoor Models) 1300 1300 1300 elecTrical daTa rated Voltage 110 / 115 230 460 Frequency (Hz) 50 / 60 50 / 60 60 Operating Range +/-10% +/-10% +/-10% Max. Power Consumption (Watts at 50 / 60 Hz) 971 / 1116 975 / 1104 1104 Max. Nominal Current (Amps at 50 / 60 Hz) 10.6 / 10.0 4.9 / 5.0 2.5 Starting Current (Amps) 40 24.5 12.5 Agency Approvals cUL Listed CE Others available upon request Power Input Description Terminal Block encloSure ProTecTion UL Type Type 12, 3R, 4 Standard Type 4X Stainless Steel Optional conTroller Description Basic Mechanical Thermostat Thermostat Location Enclosure Side Factory Thermostat Setting (F / C) 80 / 27 Sound leVel At 1.5 Meters 64.4 dBA 65.5 dBA 65.5 dBA uniT conSTrucTion Material Galvanized sheet metal standard Stainless steel optional Finish RAL 7035 light-gray, semi-textured powder-coat paint standard Other colors available acceSSorieS EASYSWAP Adaptor Plenum (GENESIS M33) Enables SPECTRACOOL to be mounted to a GENESIS M33 air conditioner cutout Catalog Number PLM33N28 uniT dimenSionS Height (in / mm) 28 / 711.2 Width (in / mm) 11.50 / 292.1 Depth (in / mm) 14.00 / 355.6 Weight (lb / kg) 84/38 84/38 92/41.7 *Units with Remote Access Control utilize a digital controller and communicate via EtherNet/IP, Profinet, Modbus TCP/IP and SNMP over ethernet or modbus RTU over USB. EQUIPMENT PROTECTION PH 763.422.2211 FAX 763.576.3200 PENTAIRPROTECT.COM Thermal managemen T 2 Spec-00732 M