Document Number: MMA1210 Freescale Semiconductor Rev 6, 09/2011 Data Sheet: Technical Data Surface Mount Micromachined Accelerometer MMA1210 The MMA series of silicon capacitive, micromachined accelerometers feature signal conditioning, a 4-pole low pass filter and temperature compensation. Zero-g offset full scale span and filter cutoff are factory set and require no external devices. A full system self-test capability verifies system functionality. Features Integral Signal Conditioning Linear Output Ratiometric Performance 4th Order Bessel Filter Preserves Pulse Shape Integrity Calibrated Self-test 16-LEAD SOIC Low Voltage Detect, Clock Monitor, and EPROM Parity Check Status Pb-FREE CASE 475-01 Transducer Hermetically Sealed at Wafer Level for Superior Reliability Robust Design, High Shocks Survivability Qualified AECQ100, Rev. F Grade 2 (-40C/+105C) Top View Typical Applications Vibration Monitoring and Recording 16 N/C 1 N/C Impact Monitoring N/C 15 N/C 2 N/C 14 3 N/C ORDERING INFORMATION ST 13 N/C 4 V 12 5 N/C OUT Device Name Temperature Range Case No. Package 11 N/C STATUS 6 10 7 N/C V MMA1210EG 40 to 125C 475-01 SOIC-16 SS 9 N/C 8 V DD MMA1210EGR2 40 to 125C 475-01 SOIC-16, Tape & Reel Pin Connections MMA1210KEG 40 to 125C 475-01 SOIC-16 MMA1210KEGR2 40 to 125C 475-01 SOIC-16, Tape & Reel K suffix indicates device manufactured with an alternate silicon sourcing. Freescale Semiconductor, Inc., 2011. All rights reserved.V DD Temp G-Cell Integrator Gain Filter V OUT Comp Sensor ST Control Logic & Clock Self-test Oscillator EPROM Trim Circuits Generator V SS STATUS Figure 1 Simplified Accelerometer Functional Block Diagram Table 1. Maximum Ratings (Maximum ratings are the limits to which the device can be exposed without causing permanent damage.) Rating Symbol Value Unit Powered Acceleration (all axes) G 1500 g pd Unpowered Acceleration (all axes) G 2000 g upd Supply Voltage V 0.3 to +7.0 V DD (1) Drop Test D 1.2 m drop Storage Temperature Range T 40 to +125 C stg 1. Dropped onto concrete surface from any axis. ELECTRO STATIC DISCHARGE (ESD) WARNING: This device is sensitive to electrostatic discharge. Although the Freescale accelerometers contain internal performance or cause failure of the chip. When handling the 2 kV ESD protection circuitry, extra precaution must be taken accelerometer, proper ESD precautions should be followed by the user to protect the chip from ESD. A charge of over to avoid exposing the device to discharges which may be 2000 volts can accumulate on the human body or associated detrimental to its performance. test equipment. A charge of this magnitude can alter the MMA1210 Sensors 2 Freescale Semiconductor