DIFFEREnTIAL PRESSURE TRAnSDUcERS High 0.08% Accuracy MicRO-MAcHineD SilicOn TRAnSDUceRS WeT/DRy DiFFeRenTiAl PReSSURe MODelS mV/V, 0 to 5 or 0 to 10 Vdc, or 4 to 20 mA Outputs Uni-Directional Ranges 0-10 inH O to 0-1000 psid 2 Standard PX409 Series U 5-Point nIST Traceable calibration U Precision micro-machined Silicon core PX409-015DDUV, U High Stability, Low Drift 15 psid range, 10 mV/V output, U Welded Stainless Steel construction shown smaller metric threads than actual size. U 316L SS Wetted Parts on Wet Side available, visit us clean Dry Gases in Dry Side online U Digital Dynamic Thermal compensation Across Temperature and Pressure Range B U Premium Temperature Performance U Broad compensated Temperature Range U Durable, 1 million cycle Life U Ruggedized with Secondary containment U customized Specifications Available These rugged stainless steel transducers are ideal PX459: m12 connector IP65 for industrial, automotive, or aerospace applications environmental rating. where only one side of the transducer is exposed to wet media. These wet/dry transducers deliver the great performance characteristics of the Micro-Machined Silicon Series Transducers at a lower price than the wet/wet models. They can be used in test benches, filter monitoring, air flow, factory or pneumatic air, pitot tubes, air speed and other industrial or aerospace applications requiring a very rugged wet/dry transducer. The solid Five Electrical state silicon core will provide long, reliable service life Termination Styles with excellent long term stability. To obtain their high PX459, m12 connector accuracy and stability, the PX409 Series use state of IP65 environmental IP67 the art digital mapping of the temperature, pressure rating. environmental and output performance of the silicon sensor in rating. conjunction with a custom ASIC to provide dynamic thermal compensation across the temperature and pressure parameters. common SPEcIFIcATIonS Accuracy: 0.08% BSL linearity, hysteresis and repeatability combined minimum Resistance Between Transducer Body and Any Wire: 100 M PX419, mini DIn. PX409, 2 m (6 ) cable. operating Temperature: IP67 mV/V and 5 to 10 Vdc output: -45 to 121C (-49 to 250F) environmental mA output: -45 to 115C (-49 to 239F) rating. compensated Temperature Range: 10 inH o to 5 psi: -17 to 85C (1 to 185F) 2 15 to 1000 psi: -29 to 85C (-20 to 185F) Thermal Accuracy: Zero Span % Span Shift over compensated temperature range 10 inH o to 5 psi: 1.00% 1.00% 2 IP65 15 to 1000 psi: 0.50% 0.50% environmental rating. Pressure cycles: 1 million minimum Long Term Stability (1-Year): 0.1% FS typical PX409c, conduit cable. PX429, twist-lock. B-232 cable style. Fast Delivery Stock to 2 Weeks On Most ModelsMicRO-MAcHineD SilicOn TRAnSDUceRS WeT/DRy DiFFeRenTiAl PReSSURe MODelS Bandwidth: DC to 1 kHz typical Response Time: <1 ms cE compliant: Meets EN61326-1: 2006 Dimensions: mm (inch) for industrial locations Shock: 50 g, 11 mS half sine, vertical and horizontal axis Conduit backend PX409C Vibration: 5-2000-5 Hz, 30 minute cycle, Curve L, Mil-Spec 810 figure 28 (1.1) 514-2-2, vertical and horizontal axis 22.8 NPT THD (0.9) media compatibility: 22.8 High Side: All fluids and gases (0.9) compatible with 316L SS Low Side: Clean, dry, Integral cable backend PX409 non-ionic gases 5 (0.2) Line/Static Pressure: 500 psi maximum applied to both sides simultaneously Proof Pressure (Differential): mating 25.4 (1.0) hex 10 inH O range = 10 times range 2 22.8 (0.875) hex connector each end 1 psi range = 6 times range each end PT06F10-6S 71.1 (2.8) 71.1 (2.8) - 18 NPT 2.5 to 750 psi ranges = 4 times range Twist-lock backend PX429 - 18 NPT each end 1000 psi range = 3 times range 5 (0.2) each end Hi Side containment Pressure (Differential): Ranges 10 inH o to 5 psi: to 1000 psi 2 Vent with porous plug 2 connector Ranges 15 to 1000 psi: to 3000 psi m12 connector (gage units only) bac end 1 backend PX459 Serial and range Pressure Ports: 4 NPT male Serial and range 20.2 20.2 identify high port mini DIN backend PX419 50.8 (2.0) Electrical Terminations: (0.8)(0.8) identify high port 50.8 (2.0) PX409: 2 m (6 ) cable 5 (0.2) 78.7 (3.1) 1 78.7 (3.1) PX409c: 2 m (6 ) cable with 2 NPT m12 x 1 2 conduit thread 30 psid and above 15 psid and below PX419: mini DIN (0.2)5 (0.2) (mating connector included) Vent with porous plug PX429: Twist-lock (mating connector (gage units only) sold separately) PX429 mating connector: PT06F10-6S PX459: M12 connector Vented Weight: 200 g (7 oz) maximum through cable Conduit backend PX409C 28 (1.1) 22.8 NPT THD (0.9) Dimensions: mm (inch) 22.8 = diameter (0.9) Integral cable backend PX409 5 (0.2) 25.4 (1.0) hex 22.8 (0.875) hex each end each end 71.1 (2.8) 71.1 (2.8) - 18 NPT Twist-lock backend PX429 - 18 NPT each end 5 (0.2) each end Vent with porous plug (gage units only) Serial and range Serial and range identify high port mini DIN backend PX419 50.8 (2.0) identify high port 50.8 (2.0) 5 (0.2) 78.7 (3.1) 78.7 (3.1) 30 psid and above 15 psid and below Vent with porous plug (gage units only) B-233