Rocker Switch A8A
Safety-considered Power Rocker Switch
Low heat radiation with a Unique leaf spring
mechanism.
Positive-opening mechanism incorporated.
AC operated Neon lamp illumination models
available.
Contact gap of 3 mm minimum.
Variety of color models available
UL and CSA standards approved. Conforms to
EN standard.
RoHS Compliant
Caution
Refer to Precautions
List of Models
Non-illuminated Models
2 1
Contact Form
Quantity per box
4 3
Color of cases White Black Gray
White A8A-201 A8A-201-1 -
Red A8A-202 A8A-202-1 A8A-202-2
Green A8A-203 A8A-203-1 A8A-203-2
Color of caps 50
Blue A8A-204 A8A-204-1 -
Yellow A8A-205 A8A-205-1 -
Black A8A-207 A8A-207-1 A8A-207-2
Note: Marking of Non-illuminated Models
The cap of the above mentioned models is without marking.
Models with marking is with suffix-@ such as A8A-201-F and A8A-201-1F.
Models with marking is with suffix-@ such as A8A-201-D and A8A-201-1D.
Consult your Omron sales representative for details.
Illuminated Models
2 1
Contact Form
Quantity per box
4 3
Rated voltage 100 VAC 200 to 220 VAC
Color of cases White Black Gray White Black Gray
Red A8A-212 A8A-212-1 A8A-212-2 A8A-222 A8A-222-1 A8A-222-2
Color of caps Green A8A-213 A8A-213-1 A8A-213-2 A8A-223 A8A-223-1 A8A-223-2 50
Orange A8A-216 A8A-216-1 A8A-216-2 A8A-226 A8A-226-1 A8A-226-2
Note: Marking of illuminated Models
The cap of the above mentioned models is without marking.
Models with marking is with suffix-@ such as A8A-212-A and A8A-212-1A.
Models with marking is with suffix-@ such as A8A-212-G and A8A-212-1G.
Consult your Omron sales representative for details.
1A8A A8A
Ratings Neon lamps
Non-inductive Inductive Models Rated voltage Rated current
Rated load
Resistive Inductive Inductive A8A-21@-@ 100 VAC 1.5 mA
Lamp load
load load motor load
A8A-22@-@ 200 to 220 VAC 1.5 mA
125 VAC 16A 10A 16A 16A
Note: 1. Life expectancy: 15,000 Hr min.
250 VAC 16A 10A 8A 16A
2. Lamp is not exchangeable.
Note: 1. The above value shows steady current.
Approved Safety Standards
2. The inductive load has a power factor of 0.4 min (AC) and a time
constant of 7 ms min (DC). UL (UL508)
3. Lamp load has an inrush current of 10 times the steady current.
16A 125 VAC, 16A 250 VAC
4. Motor load has an inrush current of 6 times the steady current.
5. The above ratings were tested under the following conditions:
CSA (CSA C22.2 No.55)
(1) Ambient temperature: 202 C
16A 125 VAC, 16A 250 VAC
(2) Ambient humidity: 655 %RH
(3) Switching frequency: 20 times/min. VDE (EN61058-1)
16A 250 VAC
Characteristics
Permissible operating speed 1 to 500 mm/s
Mechanical 30 operations / min max.
Permissible operating
frequency
Electrical 20 operations / min max.
Insulation resistance 100 M min. (at 500 VDC with insulation tester)
Contact resistance (initial value)
20 m max. (6 to 8 VDC, 1 A, voltage drop method)
Between terminals of
2.000 VAG, 50/60 Hz, for 1 min
the same polarity
Between terminals of
2.000 VAG, 50/60 Hz, for 1 min (See Note *)
Dielectric strength the different polarity
Between charged
metal parts and the 4.000 VAG, 50/60 Hz, for 1 min
ground terminal
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude
2
Shock resistance Malfunction 300 m/s max.
Mechanical 40,000 operations min.
Durability
Electrical 20,000 operations min.
Weight Non-illuminated: Approx 15g. Illuminated: Approx 16g.
Inrush current 100A max. (100 ms max.)
Ambient operating temperature - 25 to +50 C (with no icing or condensation)
Ambient operating humidity 45 to 85 %RH
Degree of protection IEC IP40
Electric shock protection class Class II
PTI (proof tracking index) 175
Pollution degree 2
Note: For the condition in individual standard, contact your OMRON sales representative.
* Condition in the Neon lamp illuminated models are excluded.
2