Temperature Controller E5C2 DIN-sized (48 x 48 mm) Temperature Controller With Analog Setting Compact, low-cost Temperature Controller. Incorporates proportional control and reset adjust- ment function. Incorporates a plug-in socket, thus allows to DIN-track and flush mounting. Ordering Information Temperature Controllers Settingg Indication Control Output Model methodh d methodh d moded Thermocouple Platinum resistance Thermistor (with sensor burnout thermometer THE detection circuit) JPt100 Diggital No indication ON/OFF Relay E5C2-R20K E5C2-R20J E5C2-R20P E5C2-R20G settini g P Relay E5C2-R40K E5C2-R40J E5C2-R40P --- Note: When placing an order, specify the standard temperature range and supply voltage in addition to the model number. (e.g., E5C2-R20K 0 C to 200 C 100/110 VAC) Accessories (Order Separately) Name Model Front Connecting Socket P2CF-08 Back Connecting Socket (for flush mounting) P3G-08 Watertight Cover Y92A-48N Temperature Ranges Input Thermocouple Platinum resistance Thermistor (see note 2) thermometer K(CA) J(IC) JPt100 THE Chromel vs. alumel Iron vs. constantan Range C 0to200 (5), 0 to 200 (5), --50 to 50 (2), --50 to 50 (2) (6 at 0 C), 0 to 300 (10), 0 to 300 (10), --20 to 80 (2), 0to100 (2)(6 at 0 C), 0 to 400 (10), 0 to 400 (10) 0to50(1), 50 to 150 (2) (30 at 0 C), 0 to 600 (20), 0 to 100 (2), 100 to 200 (2) (550 at 200 C), 0 to 800 (20), 0 to 200 (5), 150 to 300 (2) (4 at 200 C) 0 to 1,000 (25), 0 to 300 (10), 0 to 1,200 (25) 0 to 400 (10) F 32 to 392 (10), 32 to 392 (10), 32 to 212 (5), --- 32 to 572 (20), 32 to 572 (20), 32 to 392 (10) 32 to 752 (20), 32 to 752 (20) 32 to 1,112 (40), 32 to 1,472 (50), 32 to 1,832 (50), 32 to 2,192 (50) Note: 1. Values in parentheses are the smallest division. 2. Values in parentheses are the thermistor resistive value. 1E5C2 E5C2 Specifications Ratings Supply voltage 100/110, 200/220, 110/120, 220/240 VAC, 50/60 Hz Operating voltage range 90% to 110% of rated supply voltage Power consumption Approx. 2 VA Input Thermocouple (with sensor burnout detection circuit), platinum resistance thermometer, or thermistor Control mode ON/OFF or P control Setting method Analog setting Indication method No indication Control output Relay output: SPDT, 3 A at 250 VAC, resistive load (switching capacity: 330 VA) Characteristics Setting accuracy 2% FS max. Hysteresis Approx. 0.5% FS (fixed) Proportional band 3% FS (fixed) Proportional period Approx. 20 s Reset range (see note 1) 3% FS min. Insulation resistance 20 min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between charged terminals and uncharged metallic parts Vibration resistance Malfunction: 10 to 55 Hz, 0.2-mm double amplitude for 10 min each in X, Y, and Z directions Destruction: 16.7 Hz, 4-mm double amplitude for 2 hrs each in X, Y, and Z directions 2 Shock resistance Malfunction: 147 m/s (15G), 3 times each in 6 directions 2 Destruction: 294 m/s (30G), 3 times each in 6 directions Life expectancy Mechanical: 10,000,000 operations min. Electrical: 100,000 operations min. (3 A at 110 VAC, resistive load) Ambient temperature Operating: --10 Cto55 C (with no icing) Ambient humidity Operating: 45% to 85% Enclosure ratings Front panel: IEC standard IP40 (see note 2) Terminals: IEC standard IP00 Weight Approx. 200 g (with flush-mounting adapter) Note: 1. No reset function is incorporated by any E5C2 model with ON/OFF control. 2. The model number of the special watertight cover conforming to IP66, NEMA4 is Y92A-48N. Nomenclature Temperature setting knob Operation indicator RESET shaft No reset function is incorporated by any E5C2 model with ON/OFF control. Operation Indicator Indicator Output Red Lit ON Not lit OFF 2