Temperature Controller E5C2 CSM E5C2 DS E 7 2 DIN-sized (48 x 48 mm) Temperature Controller with Analog Setting Compact, low-cost Temperature Controller. Incorporates proportional control and reset adjustment function. Consecutive mounting possible using mounting adapter. Incorporates a plug-in socket, thus allows to DIN-track and flush mounting. Refer to Safety Precautions for All Temperature Controllers. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Model Number Legend E5C2- 12345 1. Control Outputs 3. Input Note: A functional explanation is provided here for illustration, but models are R: Relay K: K-type thermocouple not necessarily available for all 2. Control Method J: J-type thermocouple possible combinations. Refer to 20: ON-OFF control P-D: Platinum resistance thermometer Ordering Information when ordering. (Pt100) 40: Proportional control Examples G: Thermistor with replaceable ele- Relay control output, ON/OFF ment control, type-K thermocouple input: E5C2-R20K Relay control output, proportional control, thermocouple input: E5C2- R40P-D Ordering Information Temperature Controllers Input Thermocouple Resistance Thermometer Thermistor K (CA) J (IC) Platinum resistance Thermistor Chromel vs. alumel Iron vs. constantan thermometer Pt100 (replaceable element) 1,200 Themistor nominal resistance 1,200 1,000 6 k 6 k 30 k 550 4 k Standard 1,000 (0C) (0C) (0C) (200C)(200C) 800 scale 800 600 (C) 600 400 400 400 400 300 300 300 300 300 200 200 200 150 200 200 50 80 50 100 50 100 100 100 150 0 00000 00 0 0 0 000 00 0 50 100 50 20 50 Indica- Minimum Setting tion Control scale division 5 10 10 20 20 25 25 5 10 10 2212 5 10 10 2 2 2 2 2 method method mode Output (C) Analog No ON/OFF Relay Model E5C2-R20K E5C2-R20J E5C2-R20P-D E5C2-R20G setting indi- Propor- E5C2-R40K --- --- --- --- cation tional Relay Model (P) Note: When placing an order, specify the temperature range in addition to the model number. 1E5C2 Standard Models Indication method No indication Indication method No indication Control mode ON/OFF Proportional Control mode ON/OFF (P) Input Output Relay Input Output Relay Input/ Resis- Platinum 50 to 50 E5C2-R20P-D Input/ Thermo- K (CA) 0 to 200 E5C2-R20K E5C2-R40K stan- tance resistance 20 to 80 E5C2-R20P-D stan- couple Chromel dard Ther- thermom- 0 to 300 E5C2-R20K E5C2-R40K dard vs. alumel scale mome- eter Pt100 0 to 50 E5C2-R20P-D scale (C) ter 0 to 400 E5C2-R20K E5C2-R40K 0 to 100 E5C2-R20P-D (C) 0 to 600 E5C2-R20K E5C2-R40K 0 to 200 E5C2-R20P-D 0 to 800 E5C2-R20K E5C2-R40K 0 to 300 E5C2-R20P-D 0 to 1,000 E5C2-R20K --- 0 to 400 E5C2-R20P-D 0 to 1,200 E5C2-R20K --- Ther- THE (re- 50 to 50 E5C2-R20G J (IC) 0 to 200 E5C2-R20J --- mistor placeable 0 to 100 E5C2-R20G Iron vs. element) 0 to 300 E5C2-R20J --- constantan 50 to 150 E5C2-R20G 0 to 400 E5C2-R20J --- 100 to 200 E5C2-R20G 150 to 300 E5C2-R20G Accessories (Order Separately) Sockets Protective Cover Name Model Type Model Front Connecting Socket P2CF-08 Hard Protective Cover Y92A-48B Back Connecting Socket P3G-08 Front Connecting Socket with Finger Protection P2CF-08-E Protective Cover (for finger protection) Y92A-48G Specifications Ratings Characteristics Setting accuracy 2% FS max. (Influence of EMS : 4% FS max.) Supply voltage 100 to 240 VAC 50/60 Hz (See note 1.) Operating voltage 90% to 110% of rated supply voltage Hysteresis Approx. 0.5% FS (fixed) range Proportional band 3% FS (fixed) Power Approx. 3.6 VA Control period Approx. 20 s consumption Reset range 5 1% FS min. (See note 2.) Input Thermocouple (with sensor burnout detection Insulation 20 M min. (at 500 VDC) circuit), platinum resistance thermometer, or resistance thermistor with replaceable element Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between charged termi- Control method ON/OFF or proportional control nals and uncharged metallic parts Setting method Analog setting Vibration Malfunction: 10 to 55 Hz, 0.15-mm single amplitude for resistance 10 min each in X, Y, and Z directions Indication No indication Destruction: 16.7 Hz, 2-mm double amplitude for 2 hrs method each in X, Y, and Z directions Control output Relay output: SPDT, 3 A at 250 VAC, resistive 2 Shock resistance Malfunction: 147 m/s , 3 times each in 6 directions load (switching capacity: 330 VA) 2 Destruction: 294 m/s , 3 times each in 6 directions Ambient operat- 10C to 55C (with no icing or condensation) Life expectancy Electrical: 100,000 operations min. (3 A at 110 VAC, resistive load) ing temperature Weight Approx. 100 g (with flush-mounting adapter) Ambient operat- 45% to 85% ing humidity Degree of protection Front panel: IEC standard IP40 (See note 3.) Terminals: IEC standard IP00 Note: Do not use an inverter output as the power supply. (Refer to Applicable Socket P2CF-08 (order separately), P3G-08 (order separately) Safety Precautions for All Temperature Controllers.) Applicable Protec- Y92A-48B (order separately) tive Cover Note: 1. At EN 61326-1 (Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)) 2. No reset function is incorporated by any E5C2 model with ON/OFF control. The reset function is used to correct offset for proportional control. If there is an offset below the set value, turn the reset adjustment clockwise. 3. A special Watertight Cover is used to achieve this degree of protection (IP66, NEMA4). Refer to Y92A- N. 2