05-2019 Syr-line TMR48D Digital Timer Front Panel 48x48 (1/16 DIN) Large LED or LCD Screen (13.2 mm) Multi-function and single-function Basic & Advance configuration modes Multi-range (0.05 s 9999 h) Multi-voltage (24-240 V AC/DC) 1 or 2 relay outputs (Changeover) Memory option in event of a break in supply Lock function Up or down timing DIN Sized (48x48 mm) Housing Compact body (63 mm long) Water & Dust-proof (IP66) 8-Pins & 11-Pins connections Standard Version Performance Version (MDE1) (MDA2, MDF1, GDF1, GDS2) Product Selection Type Part Number Function Connections Output Supply Voltage Screen MDE1 MDE1R0524U A, B, C, H, D, Di 8-Pins 1 x 5A 24 V AC/DC LCD MDE1 MDE1R05MVA A, B, C, H, D, Di 8-Pins 1 x 5A 100-240 V AC/DC LCD MDA2R10MV2 A 8-Pins 2 x 10A 24-240 V AC/DC LED MDA2 MDF1 MDF1R10MV2 A, Ac, Ad, B, C, H, L, Li, D, Di 8-Pins 1 x 10A 24-240 V AC/DC LED GDF1 GDF1R10MV2 A, Ac, Ad, B, C, H, L, Li, D, Di 11-Pins 1 x 10A 24-240 V AC/DC LED GDS2 GDS2R10MV2 A, Ab, Ac, Ad, AMt, At, B, C, H, Ht, L, Li, T, W, D, Di 11-Pins 2 x 10A 24-240 V AC/DC LED Function A: ON-Delay Power Supply E: Multifunction E MV2: 24-240 V AC/DC F: Multifunction F MVA: 100-240 V AC/DC Output Type S: Multifunction S 24U: 24 V AC/DC R: Relay GD S 2 R 10 MV2 Type Output Quantity Output Power MD: Digital 8-Pins 1: 1 Output 10: 10 A GD: Digital 11-Pins 2: 2 Outputs 05: 5 A Description: The new Syr-line Digital Timers has higher precision and many programming features with the biggest screen ever seen in the timer relays market and the most intuitive programming for ease to use and fast configuration For more information about the Syr-line TMR48D Digital Timer please visit www.crouzet.com. Input Specifications Description M DE 124U M DE 1MV A GDF1 MDF1 MDA2 GDS2 100-240 V 24-240 V 24-240 V 24-240 V 24-240 V Rated supply voltage Un 24 V AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC Voltage supply tolerance -15 %, +10 % AC supply voltage frequency 50 / 60 Hz +/- 5% No Galvanic isolation of supply / inputs Max power consumption Un 2.5 VA (VAC) 1 W (VDC) Immunity to power micro cuts 10 ms Timing Specifications Description M DE 124U M DE 1MV A GDF1 MDF1 MDA2 GDS2 9 IEC 1812-1: 0. 001 s to 9.999 s, 0.01 s to 99.99 s, 0.1 s to 999.9 s, 1 s to 9999 s , 1 s to 99 min 5 Specified time ranges (10) s, 0.1 min to 999.9 min, 1 min to 9999min, 1 min to 99h 59 min , 0.1 h to 999.9 h, 1 h to 9999 h Minimum control pulse duration IEC 1812-1: 1 ms or 20 ms select able Recovery time (after by de-energization) IEC 1812-1 : 120 ms Max - Repeatability IEC 1812 1: 0.03 % 20 ms (VDC) / 5 0 ms (VAC) - Setting Accuracy IEC 1812 1: 0.03 % 20 ms (VDC) / 50 ms (VAC) Temperature drift 0.03 % 20 ms (VDC) / 50 ms (V AC) 0.03 % 20 ms (VDC) / 50 ms ( VAC) Voltage drift Output Specifications Description M DE 124U M DE 1MV A GDF1 MDF1 MDA2 GDS2 Contact arrangement 1 CO (SPDT) 1 CO (SPDT) 2 CO (SPDT) 250 VAC / 10 A resistive / 250 VAC / 10 A resistive / Maximum switching voltage 250 VAC / 30 VDC 125 VDC / 0.3 A resistive 125 VDC / 0.3 A resistive NO/NC: 2x10 A 40 C 250 V NO: 5A 250 VAC / 5 A 30 VDC NO / NC: 10 A 250 VAC / 10 A AC / 2x10 A 40 C 30 VDC Switching current rate (resistive) - NC: 3A 250 VAC / 3 A 30 30 VDC NO / NC: 2x8 A 60 C 250 V VDC AC / 2x8A 60 C 30 VDC NO: 1250 VA / 150 W NC: Maximum switching power (resistive) 2500 VA / 300 W 2 x 2500 VA / 2 x 300 W 750 VA / 90 W 5 5 5 Electrical life at nominal switching current 1x10 cycles NO 1x10 cycles (10 A 250 VAC 1x10 cycles (10 A 250 VAC 4 7x10 cycles NC resistive) resistive) rate (resistive) Minimum switching contact 10 mA / 12 VDC Maximum rate (at max switching power) 360 cycles /hour 6 10 x 10 cycles Mechanical life 1 kV / 1 min / 1 mA / 50 Hz Dielectric strength between open contacts Page 2 of 14