Temperature Controllers
E5CSV
Simple to Set and Operate 1/16 DIN Size
Controllers
Easy setting using internal DIP and rotary switches
ON/OFF or PID control (with on-demand auto-tuning)
selectable
Clearly visible digital display with character height of 13.5 mm
Deviation indicator makes monitoring more effective
Multiple temperature sensor input (thermocouple/platinum
resistance thermometer) models stocked; thermocouple
input only and platinum RTD input only models available
Models with two alarms are ideal for temperature alarm
C or F field selectable
applications
Black or white cases available to match panel aesthetics
Setting change protection prohibits tampering
RoHS compliant
Sampling rate (500 ms) and selectable control period (2 and
20 s) improves response
Water-resistant front panel rated NEMA 4X/IP66
8-mode alarm output and sensor error detection
Compact: measures 48 H x 48 W x 78 D mm
Input shift function adjusts display to reflect known sensor
Accuracy 0.5% of value
offsets
Model Number Structure
Model Number Legend
Models with Terminal Blocks
1 2 3 4 5 6
1. Output type 4. Power supply voltage
R: Relay Blank: 100 to 240 VAC
Q: Voltage for driving SSR D: 24 VAC/VDC
2. Number of alarms 5. Case color / Display scale
Blank:No alarm Blank: Black
1: 1 alarm W: Light gray
2: 2 alarms F: Scale marked in F (Black case only)
3. Input type 6. Power supply voltage
T: Thermocouple/platinum resistance thermometer AC100-240: 100 to 240 VAC
(multi-input)
AC/DC24: 24 VAC/VDC
KJ: Thermocouple
P: Platinum resistance thermometer
Note: A functional explanation is provided here for illustration, but models are not necessarily available for all possible combinations.
Please refer to Ordering Information when ordering.
Examples
Voltage control output, without alarm, multi-input, light gray case: 115 VAC: E5CSV-QT-W AC100-240
Relay control output, one alarm output, multi-input, black case: 24 VDC: E5CSV-R1TD AC/DC24
Temperature Controllers E5CSVOrdering Information
List of Models
Size Power
Number Control output TC/Pt multi-input TC input Pt input TC/Pt multi-input
supply of alarm Case color: Black Case color: Case color: Case color: Black
voltage points Scale marked in C Light gray Light gray Scale marked in F
Scale marked in C Scale marked in C
1/16 DIN 100 to 240 0 Relay E5CSV-RT AC100-240 E5CSV-RT-F AC100-240
48 48 78 mm VAC
Voltage (for driving SSR) E5CSV-QT AC100-240 E5CSV-QT-F AC100-240
(W H D)
1 Relay E5CSV-R1T AC100-240 E5CSV-R1KJ-W E5CSV-R1P-W E5CSV-R1T-F AC100-240
Voltage (for driving SSR) E5CSV-Q1T AC100-240 E5CSV-Q1KJ-W E5CSV-Q1P-W E5CSV-Q1T-F AC100-240
2 Relay E5CSV-R2T AC100-240 E5CSV-R2T-F AC100-240
(See note)
Voltage (for driving SSR) E5CSV-Q2T AC100-240 E5CSV-Q2T-F AC100-240
24 VAC/ 0 Relay E5CSV-RTD AC/DC24
VDC
Voltage (for driving SSR) E5CSV-QTD AC/DC24
1 Relay E5CSV-R1TD AC/DC24 E5CSV-R1TD-F AC/DC24
Voltage (for driving SSR) E5CSV-Q1TD AC/DC24 E5CSV-Q1TD-F AC/DC24
2 Relay E5CSV-R2TD AC/DC24
(See note)
Voltage (for driving SSR) E5CSV-Q2TD AC/DC24
Note: Models with two alarm outputs always use the upper limit alarm mode for the alarm 2 output.
Accessories (Order Separately)
Protective Cover
Type Model
Hard Protective Cover Y92A-48B
Terminal Cover
Model
E53-COV10
Specifications
Ratings
Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC/VDC, 50/60 Hz
Operating voltage range 85% to 110% of rated supply voltage
Power consumption 5 VA 3 VA/2 W
Sensor input Thermocouple input type: K, J, L
Platinum resistance thermometer input type: Pt100, JPt100
Multi-input (thermocouple/platinum resistance thermometer) type: K, J, L, T, U, N, R, Pt100, JPt100
Control Relay output SPST-NO, 250 VAC, 3A (resistive load)
output
Voltage output (for driving the SSR) 12 VDC, 21 mA (with short-circuit protection circuit)3
Control method ON/OFF or 2-PID (with auto-tuning)
Alarm output SPST-NO, 250 VAC, 1A (resistive load)
Setting method Digital setting using front panel keys
Indication method 3.5 digit, 7-segment digital display (character height: 13.5 mm) and deviation indicators
Other functions Setting change prohibit (key protection)
Input shift
Temperature unit change ( C/ F)
Direct/reverse operation
Temperature range, Sensor switching (K/J/L, Pt100/JPt100)
Switching is performed between a thermocouple and platinum resistance thermometer for multi-input models.
Control period switching
8-mode alarm output
Sensor error detection
Ambient temperature 10 to 55 C (with no condensation or icing)
Ambient humidity 25% to 85%
Storage temperature 25 to 65 C (with no condensation or icing)
2 Temperature Controllers E5CSV