Slim Relay G2RV Industrial Slim Relay Rated at 6 Amps Large plug-in terminals for reliable connection. LED indicator, clear case, and mechanical flag allows easy and immediate visual operation verification. Has a maximum switching voltage of 440 VAC. Slim outline to save space in high volume rack and PLC applications. Low power consumption for system energy savings. VDE X Model Number Structure Model Number Legend G2RV-SL - 12 3 4 5 1. Auxiliary Type Designation 3. Relay LED SL: Slim relay and socket combination 0: Without LED 2. Wire Connection 4. Relay Pushbutton 7: Screw terminals 0: Without pushbutton 5: Push-in terminals 5. Input Voltage (Complete part numbers listed in the Relay and Socket Combinations Chart below) Note: LED indicator standard feature on Socket. Ordering Information List of Models Classification Enclosure rating Input voltage Type of Contact form connection SPDT Plug-in terminals General-purpose Unsealed AC/DC Screw terminals G2RV-SL700 Push-in terminals G2RV-SL500 Relay and Socket Combinations Input voltage Screw terminals Push-in terminals 12 VDC G2RV-SL700-DC12(DC11) G2RV-SL500-DC12(DC11) LISTED 24 VDC G2RV-SL700-DC24(DC21) G2RV-SL500-DC24(DC21) Note: Relay and Socket Combinations 24 VAC/DC G2RV-SL700-AC/DC24 G2RV-SL500-AC/DC24 are UL listed. c us 48 VAC/DC G2RV-SL700-AC/DC48 G2RV-SL500-AC/DC48 110 VAC G2RV-SL700-AC110 G2RV-SL500-AC110 230 VAC G2RV-SL700-AC230 G2RV-SL500-AC230 Slim Relay G2RV 257Specifications Coil Ratings 23C Rated voltage Rated current Operate Release Power consumption Input voltage voltage voltage AC DC % of rated voltage AC (VA) DC (mW) % of rated Approx. Approx. voltage 50 Hz 60 Hz 12 VDC --- --- 27.2 80% max. 10% min. --- 300 mW 10% 24 VDC --- --- 13.3 --- 300 mW 24 VAC/DC 21.1 22.5 13.0 0.5 VA 300 mW 48 VAC/DC 8.5 9.0 5.2 0.4 VA 250 mW 110 VAC 7.1 7.5 --- 0.8 VA --- 230 VAC 7.3 7.9 --- 1.7 VA --- Contact Ratings Number of poles 1 pole Load Resistive load Inductive load (cos = 1) (cos = 0.4, L/R = 7 ms) Rated load 6 A at 250 VAC 2.5 A at 250 VAC 6 A at 30 VDC 2 A at 30 VDC Rated carry current 6 A Max. switching voltage 400 VAC, 125 VDC Max. switching current 6 A Max. switching power 1,500 VA 500 VA 180 W 60 W -6 Minimum permissible load = 0.1 x 10 /operation 10 mA at 5 VDC : P level: 60 Characteristics Item 1 pole Contact resistance 100 m max. Operate (set) time 20 ms max. Release time 40 ms max. Max. operating frequency Mechanical: 18,000 operations/hr Electrical: 1,800 operations/hr (under rated load) Insulation resistance 1,000 M min. (at 500 VDC) Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between coil and contacts 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity Vibration resistance Destruction: 10 to 55 Hz, 1.0 mm double amplitude Malfunction: 10 to 55 Hz, 1.0 mm double amplitude 2 Shock resistance Destruction: 1,000 m/s (approx. 100G) 2 2 Malfunction: 200 m/s (approx. 20G)when energized 100 m/s (approx. 10G) when not energized Life expectancy Mechanical: 5,000,000 operations min. Electrical: 100,000 typical NO 70,000 operations min. NC 50,000 operations min. Ambient temperature Operating: 40C to 55C (with no icing or condensation) Ambient humidity Operating: 5% to 85% Weight Approx. 35 g Overvoltage category III Pollution degree 2 Contact Material AgSnIn Creepage distance 7.0 mm Clearance distance 5.5 mm Note: Data shown are of initial values. 258 Slim Relay G2RV