Solid State Relays G3NA The reliable choice for Hockey-puck-style Solid State Relays. Available in a Wide Range of Currents. All models feature the same compact dimensions to provide a uniform mounting pitch. Built-in varistor effectively absorbs external surges. (except G3NA-D210B-UTU) Operation indicator enables monitoring operation. Protective cover for greater safety. Certified by UL, CSA, and TV. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions for All Solid State Relays. The following models are scheduled to close the order at the end of March 2020. Models without-UT (Not certified by TV) Models with rated input voltageAC 100-120 andAC 200-240 . Model Number Structure Model Number Legend G3NA- - 2 3 4 5 6 7 1 1. Basic Model Name 5. Terminal Type G3NA: Solid State Relay B: Screw terminals 2. Load Power Supply 6. Zero Cross Function Blank: AC output Blank: Equipped with zero cross function (AC-output models only) D: DC output 7. Certification 3. Rated Load Power Supply Voltage UTU: Certified by UL, CSA, and TV 2: 200 VAC or 200 VDC 4: 400 VAC 4. Rated Load Current Note: Not all combinations of current and voltage are available. 05: 5 A 10: 10 A 20: 20 A 25: 25 A 40: 40 A 50: 50 A 75: 75 A 90: 90 A 1G3NA Ordering Information List of Models Isolation Zero cross Indicator Applicable output load Rated input Model function (See note 1.) voltage Phototriac Yes Yes 5 A at 24 to 240 VAC 5 to 24 VDC G3NA-205B-UTU DC5-24 (See note 2.) Photocoupler 100 to 240 VAC G3NA-205B-UTU AC100-240 Phototriac 10 A at 24 to 240 VAC 5 to 24 VDC G3NA-210B-UTU DC5-24 (See note 2.) Photocoupler 100 to 240 VAC G3NA-210B-UTU AC100-240 Phototriac 20 A at 24 to 240 VAC 5 to 24 VDC G3NA-220B-UTU DC5-24 (See note 2.) Photocoupler 100 to 240 VAC G3NA-220B-UTU AC100-240 Phototriac 25 A at 24 to 240 VAC 5 to 24 VDC G3NA-225B-UTU DC5-24 (See note 2.) Photocoupler 100 to 240 VAC G3NA-225B-UTU AC100-240 Phototriac 40 A at 24 to 240 VAC 5 to 24 VDC G3NA-240B-UTU DC5-24 (See note 2.) Photocoupler 100 to 240 VAC G3NA-240B-UTU AC100-240 Phototriac 50 A at 24 to 240 VAC 5 to 24 VDC G3NA-250B-UTU DC5-24 (See note 2.) Photocoupler 100 to 240 VAC G3NA-250B-UTU AC100-240 Phototriac 75 A at 24 to 240 VAC 5 to 24 VDC G3NA-275B-UTU-2 DC5-24 (See note 2.) Photocoupler 100 to 240 VAC G3NA-275B-UTU-2 AC100-240 Phototriac 90 A at 24 to 240 VAC 5 to 24 VDC G3NA-290B-UTU-2 DC5-24 (See note 2.) Photocoupler 100 to 240 VAC G3NA-290B-UTU-2 AC100-240 10 A at 200 to 480 VAC 5 to 24 VDC G3NA-410B-UTU DC5-24 100 to 240 VAC G3NA-410B-UTU AC100-240 20 A at 200 to 480 VAC 5 to 24 VDC G3NA-420B-UTU DC5-24 100 to 240 VAC G3NA-420B-UTU AC100-240 25 A at 200 to 480 VAC 5 to 24 VDC G3NA-425B-UTU-2 DC5-24 100 to 240 VAC G3NA-425B-UTU-2 AC100-240 40 A at 200 to 480 VAC 5 to 24 VDC G3NA-440B-UTU-2 DC5-24 100 to 240 VAC G3NA-440B-UTU-2 AC100-240 50 A at 200 to 480 VAC 5 to 24 VDC G3NA-450B-UTU-2 DC5-24 100 to 240 VAC G3NA-450B-UTU-2 AC100-240 75 A at 200 to 480 VAC 5 to 24 VDC G3NA-475B-UTU-2 DC5-24 100 to 240 VAC G3NA-475B-UTU-2 AC100-240 90 A at 200 to 480 VAC 5 to 24 VDC G3NA-490B-UTU-2 DC5-24 100 to 240 VAC G3NA-490B-UTU-2 AC100-240 --- 10 A at 5 to 200 VDC 5 to 24 VDC G3NA-D210B-UTU DC5-24 100 to 240 VAC G3NA-D210B-UTU AC100-240 *All models are certified by UL, CSA, and TV. Note: 1. The applicable load is the value for when the SSR is used with silicon grease applied to the specified heat sink. The applicable load depends on the ambient temperature. Refer to Load Current vs. Ambient Temperature in Engineering Data on page 6. 2. Loss time increases under 75 VAC. (Refer to page 16.) Confirm operation with the actual load. 2