G3VM-351A/D MOS FET Relays General-purpose Series with 350-V Load Voltage. Upgraded G3VM-2 Series. Continuous load current of 120 mA. Operating time of 0.3 ms (typical). Note: The actual product is marked differently from the RoHS compliant image shown here. Application Examples Terminal Arrangement/Internal Connections Test & Measurement equipment 43 Security equipment Mold pin mark * OMRON logo Amusement equipment Model name Pin 1 mark 932 LOT.NO. 12 Note: The actual product is marked differently from the image shown here. * The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. List of Models Minimum package quantity Load voltage Package type Contact form Terminals Model (peak value) * Number per tube Number per tape and reel PCB Terminals G3VM-351A 100 - 1a DIP4 350 V G3VM-351D (SPST-NO) Surface-mounting Terminals G3VM-351D (TR) -1,500 * The AC peak and DC value are given for the load voltage. Absolute Maximum Ratings (Ta = 25C) Item Symbol Rating Unit Measurement conditions LED forward current IF 50 mA Repetitive peak LED forward current IFP 1 A 100 s pulses, 100 pps LED forward current reduction rate IF/C 0.5 mA/C Ta 25C LED reverse voltage VR 5 V Connection temperature TJ 125 C Load voltage (AC peak/DC) VOFF 350 V Continuous load current (AC peak/DC) IO 120 mA ON current reduction rate IO/C 1.2 mA/C Ta 25C Pulse ON current Iop 0.36 A t = 100 ms, Duty = 1/10 Connection temperature TJ 125 C Dielectric strength between I /O (See note 1.) VI-O 2500 Vrms AC for 1 min Note: 1. The dielectric strength between the input and Ambient operating temperature Ta 40 to +85 C With no icing or condensation output was checked by applying voltage Ambient storage temperature Tstg 55 to +125 C With no icing or condensation between all pins as a group on the LED side and Soldering temperature - 260 C 10 s all pins as a group on the light-receiving side. Electrical Characteristics (Ta = 25C) Item Symbol Minimum Typical Maximum Unit Measurement conditions LED forward voltage VF 1.0 1.15 1.3 V IF = 10 mA Reverse current IR - - 10 A VR = 5 V Note: 2. Turn-ON and Turn-OFF Times Capacity between terminals CT - 30 - pF V = 0, f = 1 MHz IF 1 4 RL Trigger LED forward current IFT - 1 3 mA IO = 120 mA VDD Turn-OFF LED forward current IFC 0.1 - - mA IOFF = 100 A VOUT 2 3 Maximum resistance -25 35 IF = 5 mA, IO = 120 mA, t<1 s RON with output ON - 35 50 IF = 5 mA, IO = 120 mA Current leakage when the relay is open ILEAK - - 1.0 A VOFF = 350 V Capacity between terminals COFF - 30 - pF V = 0, f = 1 MHz IF Capacity between I/O terminals CI-O - 0.8 - pF f = 1 MHz, VS = 0 V 8 Insulation resistance between I/O terminals RI-O 1000 10 -M VI-O = 500 VDC, ROH 60% 90% VOUT Turn-ON time tON -0.3 1.0 ms 10% IF = 5 mA, RL = 200 , t ON tOFF VDD = 20 V(See note 2.) Turn-OFF time tOFF -0.1 1.0 ms 1 Output Input Output InputG3VM-351A/D MOS FET Relays Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) VDD - - 280 V Operating LED forward current IF 5 7.5 25 mA Continuous load current (AC peak/DC) IO - - 100 mA Ambient operating Ta 20 - 65 C temperature Engineering Data LED forward current vs. Ambient Continuous load current vs. Ambient LED forward current vs. LED forward temperature temperature voltage IF - Ta IO - Ta IF - VF 100 240 100 Ta=25C 200 30 80 10 160 60 120 3 40 1 80 20 40 0.3 0 0.1 0 -20 0 20 40 60 80 100 120 0.6 0.8 1 1.2 1.4 1.6 1.8 -20 0 20 40 60 80 100 120 Ambient temperature Ta (C) Ambient temperature Ta (C) LED forward voltage VF (V) Continuous load current vs. On-state On-state resistance vs. Ambient Trigger LED forward current vs. voltage temperature Ambient temperature IO - VON RON - Ta IFT - Ta 200 50 5 Ta = 25C IO = 120mA IO = 120mA IF = 5mA IF = 5mA t < 1s t < 1s 40 4 100 30 3 0 20 2 -100 10 1 0 0 -200 -4 -3 -2 -1 0 1 2 3 4 -20 0 20 40 60 80 100 -20 0 20 40 60 80 100 On-state voltage VON (V) Ambient temperature Ta (C) Ambient temperature Ta (C) Turn ON, Turn OFF time vs. LED Turn ON, Turn OFF time vs. Ambient Current leakage vs. Ambient forward current temperature temperature tON, tOFF - IF tON, tOFF - Ta ILEAK - Ta 3000 3000 100 Ta = 25C VOFF = 350V VDD = 20V RL = 200 30 1000 1000 tON 10 300 300 tOFF 3 100 100 tOFF 1 30 30 VDD = 20V 0.3 RL = 200 tON IF = 5mA 10 10 0.1 1 3 10 30 100 300 -20 0 20 40 60 80 100 -20 0 20 40 60 80 100 LED forward current IF (mA) Ambient temperature Ta (C) Ambient temperature Ta (C) Safety Precautions Refer toCommon Precaution for all G3VM models. 2 Continuous load current IO (mA) Turn ON, Turn OFF time tON, tOFF (s) LED forward current IF (mA) Turn ON, Turn OFF time tON, tOFF (s) Continuous load current IO (mA) On-state resistance RON () Current leakage ILEAK (nA) LED forward current IF (mA) Trigger LED forward current IFT (mA)