G3VM-351B/E MOS FET Relays General-purpose Series with 350-V Load Voltage. Upgraded G3VM-3 Series. Continuous load current of 120 mA. Dielectric strength of 2,500 Vrms between I/O. Operating time of 0.3 ms (typical). RoHS compliant Note: The actual product is marked differently from the image shown here. Application Examples Terminal Arrangement/Internal Connections 6 54 Test & Measurement equipment OMRON logo Security equipment Model name Amusement equipment Pin 1 mark 932 LOT.NO. 132 Note: The actual product is marked differently from the image shown here. List of Models Minimum package quantity Load voltage Package type Contact form Terminals Model (peak value) * Number per tube Number per tape and reel PCB Terminals G3VM-351B 1a 50 - DIP6 350 V G3VM-351E (SPST-NO) Surface-mounting Terminals G3VM-351E (TR) -1,500 * The AC peak and DC value are given for the load voltage. Absolute Maximum Ratings (Ta = 25 C) Item Symbol Rating Unit Measurement conditions Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on LED forward current IF 50 mA the LED side and all pins as a group on the light-receiving side. Repetitive peak LED forward current IFP 1 A 100 s pulses, 100 pps Connection Diagram LED forward current reduction rate IF/C 0.5 mA/C Ta 25C LED reverse voltage VR 5 V 1 6 Load Connection temperature TJ 125 C Connection 2 5 or AC Load voltage (AC peak/DC) VOFF 350 V A DC 3 4 Connection A 120 Continuous Connection A: AC peak/DC Connection B IO 120 mA load current Connection B and C: DC Connection C 240 1 6 Load Connection Connection A 1.2 ON current 2 5 DC B reduction Connection B IO/C 1.2 mA/C Ta 25C 3 4 rate Connection C 2.4 Connection temperature TJ 125 C 1 6 Load Dielectric strength between I /O (See note 1.) VI-O 2500 Vrms AC for 1 min Connection Ambient operating temperature Ta 40 to +85 C With no icing or condensation 2 5 DC C Ambient storage temperature Tstg 55 to +125 C With no icing or condensation 3 4 Soldering temperature -260 C 10 s Electrical Characteristics (Ta = 25 C) Item Symbol Minimum Typical Maximum Unit Measurement conditions LED forward voltage VF 1.0 1.15 1.3 V IF = 10 mA Reverse current IR - - 10 A VR = 5 V Capacity between terminals CT - 30 - pF V = 0, f = 1 MHz Note: 2. Turn-ON and Turn-OFF Times Trigger LED forward current IFT -1 3 mA IO = 120 mA IF -25 35 IF = 5 mA, IO = 120 mA, t<1 s 1 6 RL Connection A VDD Maximum -35 50 IF = 5 mA, IO = 120 mA VOUT resistance with RON 2 4 Connection B -28 40 IF = 5 mA, IO = 120 mA output ON Connection C -14 20 IF = 5 mA, IO = 240 mA Current leakage when the relay is open ILEAK -- 1.0 A VOFF = 350 V Capacity between terminals COFF - 30 - pF V = 0, f = 1 MHz IF Capacity between I/O terminals CI-O - 0.8 - pF f = 1 MHz, VS = 0 V Insulation resistance between I/O terminals RI-O 1000 - - M VI-O = 500 VDC, ROH 60% 90% VOUT Turn-ON time tON -0.3 1.0 ms IF = 5 mA, RL = 200 , 10% tON tOFF Turn-OFF time tOFF -0.1 1.0 ms VDD = 20 V(See note 2.) 1 Output Input Output InputG3VM-351B/E MOS FET Relays Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) VDD -- 280 V Operating LED forward current IF 5 10 25 mA Continuous load current (AC peak/DC) IO -- 100 mA Ambient operating temperature Ta 20 - 65 C Engineering Data LED forward current vs. Ambient Continuous load current vs. Ambient LED forward current vs. LED forward temperature temperature voltage IF - Ta IO - Ta IF - VF 100 280 100 Ta = 25C Connection C 240 30 80 200 10 60 160 3 Connection A and B 120 40 1 80 20 0.3 40 0 0 0.1 -20 020 40 60 80 100 120 -20 020 40 60 80 100 120 0.6 0.8 1 1.2 1.4 1.6 1.8 Ambient temperature Ta (C) Ambient temperature Ta (C) LED forward voltage VF (V) Continuous load current vs. On-state On-state resistance vs. Ambient Trigger LED forward current vs. voltage temperature Ambient temperature IO - VON RON - Ta IFT - Ta 200 50 5 Ta = 25C IO = 120mA IO = 120mA IF = 5mA IF = 5mA t < 1s t < 1s Connection A 40 4 Connection A 100 30 3 0 20 2 -100 10 1 0 0 -200 -20 020 40 60 80 100 -20 020 40 60 80 100 -4 -3 -2 -1 0 1 2 3 4 On-state voltage VON (V) Ambient temperature Ta (C) Ambient temperature Ta (C) Turn ON, Turn OFF time vs. LED Turn ON, Turn OFF time vs. Ambient Current leakage vs. Ambient forward current temperature temperature tON, tOFF - IF tON, tOFF - Ta ILEAK - Ta 3000 3000 30 Ta = 25C VOFF = 350V VDD = 20V RL = 200 1000 10 1000 tON 3 300 300 tOFF 1 100 100 tOFF 0.3 30 30 VDD = 20V RL = 200 tON IF = 5mA 0.1 10 10 -20 020 40 60 80 100 1 3 10 30 100 300 -20 020 40 60 80 100 Ambient temperature Ta (C) LED forward current IF (mA) Ambient temperature Ta (C) Safety Precautions Refer toCommon Precaution for all G3VM models. 2 Turn ON, Turn OFF time tON, tOFF (s) Continuous load current IO (mA) LED forward current IF (mA) Turn ON, Turn OFF time tON, tOFF (s) On-state resistance RON ( ) Continuous load current IO (mA) Current leakage ILEAK (nA) Trigger LED forward current IFT (mA) LED forward current IF (mA)