G3VM-41GR4 MOS FET Relays MOS FET Relays with Low Output Capacitance and ON Resistance (C R = 10pF ) in a 40-V Load Voltage Model. ON resistance of 2 (typical) suppresses output signal attenuation. Leakage current of 1.0 nA max. when output relay is open. RoHS compliant Note: The actual product is marked differently from the image shown here. Application Examples Terminal Arrangement/Internal Connections Semiconductor test equipment 43 Test & Measurement equipment Mold pin mark * Communication equipment OMRON logo Model name Data loggers 932 LOT.No. Pin 1 mark 12 Note:The actual product is marked differently from the image shown here. * The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. List of Models Minimum package quantity Load voltage Package type Contact form Terminals Model (peak value) * Number per tube Number per tape and reel G3VM-41GR4 100 - 1a SOP4 Surface-mounting Terminals 40 V (SPST-NO) G3VM-41GR4 (TR) -2,500 * The AC peak and DC value are given for the load voltage. Absolute Maximum Ratings (Ta = 25 C) Item Symbol Rating Unit Measurement conditions LED forward current IF 50 mA LED forward current reduction rate IF/C 0.5 mA/C Ta 25C LED reverse voltage VR 5 V Connection temperature TJ 125 C Load voltage (AC peak/DC) VOFF 40 V Continuous load current (AC peak/DC) IO 250 mA ON current reduction rate IO/C 2.5 mA/C Ta 25C Connection temperature TJ 125 C Dielectric strength between VI-O 1500 Vrms AC for 1 min I/O (See note 1.) Note: 1. The dielectric strength between the input and Ambient operating temperature Ta 20 to +85 C With no icing or condensation output was checked by applying voltage Ambient storage temperature Tstg 55 to +125 C With no icing or condensation between all pins as a group on the LED side and Soldering temperature -260 C 10 s all pins as a group on the light-receiving side. Electrical Characteristics (Ta = 25 C) Item Symbol Minimum Typical Maximum Unit Measurement conditions LED forward voltage VF 1.0 1.15 1.3 V IF = 10 mA Note: 2. Turn-ON and Turn-OFF Times Reverse current IR - - 10 A VR = 5 V IF 1 4 RL VDD Capacity between terminals CT - 15 - pF V = 0, f = 1 MHz VOUT 2 3 Trigger LED forward current IFT - - 4 mA IO =100 mA Maximum resistance with output ON RON - 2.0 3.0 IF = 5 mA, IO = 250 mA, t < 1 s Current leakage when the relay is open ILEAK - - 1.0 nA VOFF = 30 V, Ta = 50 C Capacity between terminals COFF - 5 7 pF V = 0, f = 100 MHz, t < 1 s IF Capacity between I/O terminals CI-O - 0.8 - pF f = 1 MHz, VS = 0 V Insulation resistance between I/O terminals RI-O 1000 - - M VI-O = 500 VDC, ROH 60 % 90% VOUT Turn-ON time tON -- 0.5 ms IF = 10 mA, RL = 200 , 10% VDD = 20 V (See note 2.) t ON t OFF Turn-OFF time tOFF -- 0.5 ms 1 Output Input Output InputG3VM-41GR4 MOS FET Relays Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) VDD -- 32 V Operating LED forward current IF 10 - 30 mA Continuous load current (AC peak/DC) IO -- 250 mA Ambient operating temperature Ta 25 - 60 C Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature LED forward current vs. LED forward voltage IF - Ta IO - Ta IF - VF 100 500 100 Ta = 25 C 50 80 400 30 10 60 300 5 3 40 200 1 0.5 20 100 0.3 0.1 0 0 -20 020 40 60 80 100 120 -20 020 40 60 80 100 120 0.6 0.8 1 1.2 1.4 1.6 1.8 Ambient temperature Ta (C) Ambient temperature Ta (C) LED forward voltage VF (V) Continuous load current vs. On-state voltage On-state resistance vs. Ambient temperature Trigger LED forward current vs. Ambient temperature IO - VON RON - Ta IFT - Ta 300 5 5 IO = 250 mA Ta = 25 C IO = 100 mA IF = 5 mA t < 1s IF = 5 mA t < 1s 200 4 4 100 3 3 0 2 2 -100 1 1 -200 0 0 -300 -20 020 40 60 80 100 -20 020 40 60 80 100 -1 -0.5 0 0.5 1 Ambient temperature Ta (C) Ambient temperature Ta (C) On-state voltage VON (V) Turn ON, Turn OFF time vs. LED forward current Turn ON, Turn OFF time vs. Ambient temperature Current leakage vs. Load voltage tON, tOFF - IF tON, tOFF - Ta ILEAK - VOFF 1000 300 15 VDD = 10 V Ta = 25 C Ta = 25 C RL = 200 VDD = 10 V, RL = 200 IF = 10 mA 250 300 200 10 tOFF 100 tOFF 150 30 100 5 tON tON 10 50 0 3 -20 020 40 60 80 100 1 10 100 0 10 20 30 40 LED forward current IF (mA) Ambient temperature Ta (C) Load voltage (V) Output terminal capacitance vs. Load voltage COFF - VOFF 1 Ta = 25 C 0.8 0.6 0.4 0.2 0 10 20 30 40 50 Load voltage (V) Safety Precautions Refer toCommon Precaution for all G3VM models. 2 Continuous load current IO (mA) LED forward current IF (mA) Output terminal capacitance COFF/COFF (0V) Turn ON, Turn OFF time tON, tOFF (s) Turn ON, Turn OFF time tON, tOFF (s) Continuous load current IO (mA) On-state resistance RON ( ) LED forward current IF (mA) Current leakage ILEAK (pA) Trigger LED forward current IFT (mA)