G3VM-601AY/DY MOS FET Relays Compact, General-purpose, Analog- switching MOS FET Relays, with Dielectric Strength of 5 kVAC between I/O Using Optical Isolation. Trigger LED forward current of 2 mA (maximum) facilities power saving designs. Switches minute analog signals. Continuous load current of 90 mA. Note: The actual product is marked differently from the image RoHS compliant shown here. Refer to Common Precautions. Application Examples Power meter Measurement devices Security systems Industrial equipment List of Models Contact form Terminals Load voltage (peak value) Model Number per stick Number per tape (See the note.) SPST-NO PCB terminals 600 V G3VM-601AY 100 --- Surface-mounting G3VM-601DY terminals G3VM-601DY(TR) --- 1,500 Note: The AC peak and DC value are given for the load voltage. Dimensions Note: All units are in millimeters unless otherwise indicated. G3VM-601AY 0.25 G3VM-601DY 4.58 4.580.25 0.25 6.4 0.25 6.4 7.620.25 0.25 7.62 0.80.25 +0.15 +0.15 3.65 +0.25 0.25 3.65 0.25 4.0 0.2 1.0 +0.1 0.25 0.05 min. 0.15 Note: The actual product Note: The actual product 1.2 0.15 1.0 min. 1.2 is marked different- 2.5 min. is marked different- 10.0 max. 7.85 to 8.80 0.50.1 0.25 ly from the image ly from the image 2.54 shown here. 0.25 shown here. Weight: 0.25 g 2.54 Weight: 0.25 g Terminal Arrangement/Internal Connections (Top View) G3VM-601AY 43 G3VM-601DY43 Mold pin mark OMRON logo Model name Pin 1 mark LOT.NO. 12 12 Note: The actual product is marked differently from the image shown here. PCB Dimensions (Bottom View) Actual Mounting Pad Dimensions (Recommended Value, Top View) G3VM-601AY Four 0.8-dia. holes 2.54 (0.61) G3VM-601DY 2.54 2.54 8.3 to 8.8 (0.61) (1.52) (1.52) 1.3 1.5 1G3VM-601AY/DY G3VM-601AY/DY Absolute Maximum Ratings (Ta = 25C) Item Symbol Rating Unit Measurement Conditions Note: 1. The dielectric strength between the input and Input LED forward current I 30 mA F output was checked by applying voltage be- Repetitive peak LED forward I 1 A 100 s pulses, 100 pps FP tween all pins as a group on the LED side and current all pins as a group on the light-receiving side. LED forward current reduc- I / C 0.3 mA/ CTa 25 C F tion rate LED reverse voltage V 5V R Connection temperature T 125 C j Output Load voltage (AC peak/DC) V 600 V OFF Continuous load current (AC I 90 mA O peak/DC) ON current reduction rate I / C 0.9 mA/ CTa 25 C O Pulse ON current I 0.27 A t = 100 ms, Duty = 1/10 op Connection temperature T 125 C j Dielectric strength between input and V 5,000 Vrms AC for 1 min I-O output (See note 1.) Operating temperature T 40 to +85 C With no icing or condensation a Storage temperature T 55 to +125 C With no icing or condensation stg Soldering temperature (10 s) --- 260 C 10 s Electrical Characteristics (Ta = 25 C) Item Symbol Mini- Typical Maxi- Unit Measurement mum mum conditions Note: 2. Turn-ON and Turn-OFF Input LED forward voltage V 1.45 1.63 1.75 V I = 10 mA F F Times Reverse current I --- --- 10 AV = 5 V R R IF 1 4 RL VDD Capacity between terminals C --- 40 --- pF V = 0, f = 1 MHz T VOUT 2 3 Trigger LED forward current I --- 0.3 2 mA I = 90 mA FT O Output Maximum resistance with output ON R --- 30 40 I = 5 mA, ON F I = 90 mA, t < 1 s O 45 60 I = 5 mA, F IF I = 90 mA O Current leakage when the relay is I --- --- 1.0 AV = 600 V LEAK OFF open 90% VOUT 10% Capacity between terminals C --- 75 --- pF V = 0, f = 1 MHz OFF t ON t OFF Capacity between I/O terminals C --- 0.8 --- pF f = 1 MHz, Vs = 0 V I-O Insulation resistance R 1,000 --- --- M V = 500 VDC, I-O I-O RoH 60% Turn-ON time tON --- 0.2 1 ms I = 5 mA, R = 200 F L V = 10 V (See note 2.) DD Turn-OFF time tOFF --- 0.2 1 ms Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) V --- --- 480 V DD Operating LED forward current I 3520 mA F Continuous load current (AC peak/DC) I --- --- 90 mA O Operating temperature T 20 --- 65 C a Engineering Data Safety Precautions Refer to Common Precautions for all G3VM models. Load Current vs. Ambient Temperature G3VM-601AY(DY) 140 120 100 80 60 40 20 0 20 0 20 40 60 80 100 Ambient temperature (C) 2 Load current (mA)