PCB Relay G5CA Flat Relays that Switch 10-A/15-A Loads with New Quick-connect Terminals Ideal for switching power in household appliances or for outputs from industrial devices. Subminiature dimensions: 16 x 22 x 11 mm (L x W x H). High-sensitivity models available with low power consumption (150 mW). UL recognized / CSA certified. Fully sealed models and quick-connect terminal models available ( 187 load contact terminals). RoHS Compliant. Ordering Information To order: Select the part number and add the rated coil voltage to the part number. Example: G5CA-1A4-H DC12. Item Model Enclosure Contact Standard High-sensitivity High-capacity Quick-connect terminals Ratings configuration ( 187) Flux protection SPST-NO G5CA-1A G5CA-1A-H G5CA-1A-E G5CA-1A-TP-E Fully sealed G5CA-1A4 G5CA-1A4-H --- --- Note: 1. Contact your OMRON representative for details on other coil voltage specifications. 2. High-capacity models with a fully sealed structure are not available. 3. Standard or high-sensitivity models with quick-connect terminals are not available. Model Number Legend G5CA-1A - - - 1 2 34 5 Standard Specifications 1. Number of Poles 2. Enclosure Ratings 4. Special functions None: Flux protection 1A: 1 pole (SPST-NO) None: Standard Contact Configuration:SPST-NO 4: Fully sealed E: High-capacity Enclosure Ratings: Flux protection 5. Coil consumption 3. Terminal form None: Standard Terminal form: PCB terminal None: PCB terminal H: High-sensitivity TP: Quick-connect terminal ( 187) PCB Relay G5CA 203Specifications Coil Ratings Item Standard, high-capacity, or quick-connect terminals High-sensitivity 5 VDC 12 VDC 24 VDC 5 VDC 12 VDC 24 VDC Rated current 40 mA 16.7 mA 8.3 mA 30 mA 12.5 mA 6.25 mA Coil resistance 125 720 2,880 167 960 3,840 Must-operate voltage 75% of rated voltage (max.) 80% of rated voltage (max.) Must-release voltage 10% of rated voltage (min.) Max. voltage 150% (standard)/130% (high-capacity, quick-connect 150% of rated voltage at 23C terminals) of rated voltage (at 23C) Power consumption Approx. 200 mW Approx. 150 mW Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C (73F) with a tolerance of 10%. 2. The operating characteristics are measured at a coil temperature of 23C. 3. Themaximum voltag is the maximum voltage that can be applied to the relay coil. Contact Ratings Item Standard High-sensitivity High-capacity, or quick-connect terminals Resistive load Inductive load Resistive load Inductive load Resistive load Inductive load (cos = 0.4, (cos = 0.4, (cos = 0.4, L/R = 7 ms) L/R = 7 ms) L/R = 7 ms) Contact form Single Contact material Silver alloy Rated load 10 A at 250 VAC 3 A at 250 VAC 10 A at 250 VAC 3 A at 250 VAC 15 A at 110 VAC 5 A at 110 VAC 10 A at 30 VDC 3 A at 30 VDC 10 A at 30 VDC 3 A at 30 VDC 10 A at 30 VDC 3 A at 30 VDC Rated carry current 10 A 10 A 15 A Max. switching voltage 250 VAC, 125 VDC Max. switching current 10 A 10 A 15 A Max. switching power 2,500 VA, 300 W 750 VA, 90 W 2,500 VA, 300 W 750 VA, 90 W 2,500 VA, 300 W 750 VA, 90 W (reference value) 204 PCB Relay G5CA