Special-purpose PCB Relay G5PA-1 G5PA Ideal for Power Switching and Isolation of TV Screen, TV Tuner, Video Accessories, and Audio Systems High-capacity, high-isolation switching ideal for todays re- mote controlled large-screen TVs with built-in tuners and accessories (DVD, TiVO, etc.). Power saving for todays energy conservation require- ments Reduced 250 mW power consumption (150 mW optional). Achieves 5 year HDTV/large screen very high inrush TV power switching ( std. 1/hr) Extended contact gap provides isolation from devastating lightning strikes and power grid surges. Equipped with double-insulation construction assuring iso- lation of video/data feed and accessories from power. Models conforming to UL508, CSA C22.2, VDE0435/ IEC255, and SEMKO are available. Ordering Information Classification Contact form Enclosure ratings Model Standard SPST-NO Flux protection G5PA-1 Note: When ordering, add the rated coil voltage to the model number. Example: G5PA-1 12 VDC Rated coil voltage Model Number Legend G5PA-1----DC 12 3 4 Number of poles 2. Power Usage 3. Capacity 1: 1 pole, form A (SPST-NO) No symbol: 250 mW No symbol: 5A, 250 mW -H: 150 mW -E: 10A, 540 mW 1. Seal Rating -M: 540 mW -H-E 1A, 250 mW No symbol: flux sealed (IP-52) -S: fully sealed (IP-67) 4. Rated for Coil Voltage 5, 6, 9, 12, 18, 24 VDC (3 VDC possible) Note: 1. optional low audible version 2. former -8-type (.42 mm coil terminal) is now standard Special-purpose PCB Relay G5PA-1 1Specifications Coil Ratings Rated voltage 12 VDC 24 VDC Rated current 20.8 mA 10.4 mA Coil resistance 576 2,304 Must operate voltage 80% of rated voltage max. Must release voltage 10% of rated voltage min. Max. permissible voltage 150% of rated voltage (at 23 C) Power consumption 250 mW (other options available) Note: 1. Each rated current or coil resistance value must allow a tolerance of 10% at a coil temperature of 23C. 2. The operating characteristics are values at a coil temperature of 23C. 3. The maximum permissible voltage is the maximum voltage that is applicable to the relay coil for an instant. Contact Ratings Rated load (capacitive load) 250 VAC with inrush current of 100 A (0 to peak) and constant current of 3 A (rms) Resistive load (reference value) 10 A 250 VAC 5A 30 VDC/277 VAC ( 40 C) Max. switching voltage 277 VAC, 30 VDC Max. switching current 10 A ( 40 C) Characteristics Contact resistance (see note 2) 100 m max. Operate time 15 ms max. Release time 5 ms max. Insulation resistance (see note 3) 1,000 M min. (at 500 VDC) Dielectric strength 4,000 VAC 50/60 Hz for 1 min between coil and contacts 1,000 VAC 50/60 Hz for 1 min between contacts of same polarity Impulse withstand voltage 10 kV (1.2 x 50 s between coil and contacts), 12 kV optional Vibration resistance Destruction:10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction:10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) 2 Shock resistance Destruction:1,000 m/s 2 Malfunction: 200 m/s Endurance Mechanical: 1,000,000 operations min. (at 18,000 operations an hour) Electrical: 40,000 operations min. with a rated load at a 1,800 operations an hour. 100,000 operations min. with a resistive load (reference value) Ambient temperature Operating: -40C to 70C (with no icing) Ambient humidity Operating: 5% to 85% Weight Approx. 10 g Approved Standards UL (File No. E41515, UL508) CSA (File No. LR31928, C22.2 No. 14) Model Coil ratings Contact ratings Number of test operations G5PA-1 5 to 24 VDC ( 40 C) 5 A, 277 VAC 30,000 5 A, 30 VDC 6,000 30,000 (optional) 10 A, 250 VAC 100,000 TV-5 rating 25,000 TV-8 rating 25,000 (optional) 2 Special-purpose PCB Relay G5PA-1