PCB Relay G5Q Compact, High Isolation Relay Compact single pole relay with high isolation between coil and contacts. Ensures a withstand impulse voltage of 8,000V between the coil and contacts. Low coil power consumption. UL class F coil insulation. UL recognized / CSA certified. EN approved. Ideal for appliance and HVAC controls RoHS Compliant Ordering Information To Order: Select the part number and add the desired coil voltage and rating. (e.g., G5Q-14 DC12) Classification Enclosure rating Model Single contact, class F coil insulation SPST-NO Vented G5Q-1A Sealed G5Q-1A4 SPDT Vented G5Q-1 Sealed G5Q-14 Note: Add -EU before the coil voltage to obtain versions with CTI > 250. (e.g., G5Q-1A4-EU DC12) Specifications forE type differ from standard models. Contact Omron for more details Specifications Coil Ratings Pick-up Drop-out Maximum Power Rated coil Coil resistance voltage voltage voltage Rated voltage (V) consumption current (mA) () (mW) Percent of rated voltage SPDT DC 5 80 63 75% max 5% min 190% 23C 400 DC 9 44.4 202 DC 12 33.3 360 DC 24 16.7 1440 SPST-NO DC 5 40 125 200 DC 9 22.2 405 DC 12 16.7 720 DC 24 8.3 2880 Note: Rated current and coil resistance are measured at 23C with a tolerance of 10%. PCB Relay G5Q 163 Contact Ratings Item SPDT SPST-NO Rated load (resistive) 10 A at 125 VAC (NO) 10 A at 125 VAC 3 A at 250 VAC (NO) 3 A at 250 VAC 5 A at 30 VDC (NO) 5 A at 30 VDC 3 A at 125 VAC (NC) 3 A at 30 VDC (NC) Contact material Ag alloy Rated carry current 10 A (NO)/3 A (NC) Max. switching voltage 277 VAC, 30 VDC Max. switching current AC: 10 A (NO)/3 A (NC) DC: 5 A (NO)/3 A (NC) Max. switching capacity 1250 VA, 150 W (NO) 375 VA, 90 W (NC) 6 Min. permissible load 10 mA at 5 VDC (P level: = 0.1 10 /operation) 60 Characteristics Contact resistance (See note 2.) 100 m max. Operate time 10 ms max. Release time 5 ms max. Insulation resistance (See note 3.) 1,000 m min. Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between coil and contacts 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity Impulse withstand voltage 8 kV (1.2 50 s) between coil an contacts Vibration resistance Destruction: 10 to 55 to 10 Hz, 1.5-mm double amplitude Malfunction: 10 to 55 to 10 Hz, 1.5-mm double amplitude 2 Shock resistance Destruction: 1000 m/s (approx. 100G) 2 Malfunction: 100 m/s (approx. 10G) Life expectancy (See Note 4) Mechanical 10,000,000 operations (18,000 operations per hour) Electrical 200,000 operations: 3 A (NO)/3 A (NC) at 125 VAC, resistive load 100,000 operations: 3 A (NO)/3 A (NC) at 250 VAC, 5 A (NO)/3 A (NC) at 30 VDC, resistive load 50,000 operations: 10 A at 125 VAC (900 operations per hour) Ambient temperature Operating & 40 C to 105C (-40F to 221F) with no icing or condensation storage Ambient humidity Operating & 5% to 85% storage Note: 1. The data shown above are initial values. 2. The contact resistance is measured with 1 A applied at 5 VDC using a fall-of-potential method. 3. The insulation resistance is measured between coil and contacts and between contacts of the same polarity at 500 VDC. 4. The electrical life data items shown are possible at 23C 164 PCB Relay G5Q