- - - G5Q-EL/-EL2/-EL3 PCB Power Relay A Miniature Power Relay with high performance IEC/EN 60335-1 conformed. Coil insulation system: class F (UL1446) Type G5Q-EL Higher performance compare with G5Q standard type. Minimum 100,000 operations durability at 10 A (250 VAC) switching. Type G5Q-EL2 High inrush capacity performance (Inrush current 40 A). UL508 TV3 conformed. Type G5Q-EL3 Ideal for motor switching 3 A with high inrush 30 A IEC/EN 60079-15 conformed. RoHS Compliant G Model Number Legend Application Examples 5 Q G5Q- - - - Home appliances E Building automation 12 3 4 5 6 L 1. Number of Pole 4. Classification Lighting control / 1 : 1-pole EL : For Resistive load Output of control system E EL2 : For Inrush load 2. Contact Form L FA I/O module EL3 : For Motor load A : SPST-NO (1a) 2 / 5. Market Code 3. Enclosure rating HA : Home Appliance according E None : Flux protection to IEC/EN60335-1 L (-EL type only) 3 4 : Fully sealed 6. Case Vent Hole (-EL2, -EL3) None : No vent hole VH : Vent hole (-EL type only) Ordering Information Classification Contact form Enclosure rating Model Rated coil voltage Minimum packing unit 5 VDC -EL type Flux protection SPST-NO (1a) G5Q-1A-EL-HA-VH 12 VDC (For Resistive load) (Vent hole type) 24 VDC 5 VDC -EL2 type SPST-NO (1a) Sealed G5Q-1A4-EL2-HA 12 VDC 100 pcs/tray (For Inrush load) 24 VDC 5 VDC -EL3 type SPST-NO (1a) Sealed G5Q-1A4-EL3-HA 12 VDC (For Motor load) 24 VDC Note 1. When ordering, add the rated coil voltage to the model number. Example: G5Q-1A4-EL2-HA DC12 Rated coil voltage Note 2. Contact your OMRON sales representative for tube packing models. Ratings Coil Must operate voltage (V) Must release voltage (V) Max. voltage (V) Rated current Coil resistance Power consumption Rated voltage (mA) () (mW) % of rated voltage 5 VDC 63 80.0 190% 12 VDC 360 75% max. 5% min. Approx. 400 33.3 (at 23C) 24 VDC 1440 16.7 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. Note 3. The Max. voltage is the maximum voltage that can be applied to the relay coil. Note 4. 5 VDC of coil rated voltage is available only for EL3 1- - - G5Q-EL/-EL2/-EL3 PCB Power Relay Contacts Load -EL type (For Resistive load) -EL2 type (For Inrush load) -EL3 type (For Motor load) SPST-NO (1a) Item Flux protection Sealed Sealed Contact type Single Contact material Ag-Alloy (Cd free) Capacitive load Inrush 40 A (100 s) / Motor load : Inrush 30 A (0.5 s) / Rated load Resistive load 10 A at 250 VAC 1 A break at 250 VAC 3 A break cos=0.5 at 250 VAC Rated carry current 10 A Max. rated voltage 277 VAC Max. rated current 10 A AC Characteristics Item Classification -EL type (For Resistive load) -EL2 type (For Inrush load) -EL3 type (For Motor load) Contact resistance *1 100 m max. Operate time 10 ms max. Release time 5 ms max. Insulation resistance *2 1,000 M min. (at 500 VDC) Between coil and 4,000 VAC, 50/60 Hz for 1 min contacts Dielectric strength Between contacts of the 1,000 VAC, 50/60 Hz for 1 min same polarity G 5 Impulse withstand Between coil and 8 kV (1.2 x 50 s) Q voltage contacts E Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Vibration resistance L Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) / 2 Destruction 1,000 m/s E Shock resistance 2 Malfunction 100 m/s L 2 Mechanical 10,000,000 operations (18,000 operations per hour) / Resistive load Capacitive load Motor load E Durability 100,000 operations at 23C 100,000 operations at 23C 300,000 operations at 23C Electrical L (operation: ON for 1 sec. OFF for 9 (operation: ON for 1 sec. OFF for 3 (operation: ON for 1 sec. OFF for 1 3 sec.) sec.) sec.) Failure rate (P level) (reference *3) 10 mA at 5 VDC Ambient operating temperature -40C to 85C (with no icing or condensation) Ambient operating humidity 5% to 85% Weight Approx. 6.5 g Note. Values in the above table are the initial values at 23C. *1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method. *2. Testing conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the electric strength was measured. *3. This value was measured at switching frequency of 120 operation/min. Engineering Data Maximum Switching Capacity Ambient Temperature VS. Shock Malfunction (AC) Maximum Coil Voltage 200 100 1,000 180 160 X Z 1,000 1,000 140 AC resistive load 120 Energized 100 10 De-energized 200 80 1,000 1,000 800 Z X 60 40 1,000 20 2 Y Unit: m/s Sample: G5Q-1A-EL-HA-VH Shock direction 0 1 -40 -20 0 20 23 40 60 80 100 120 1 10 100 1000 XX Number of Relays: 5 pcs Y Test conditions: Shock is applied Z Switching voltgate (V) Ambient temperature (C) in X, Y, and Z directions three Z times each with without Note. The Maximum coil voltage refers to the Y energizing the Relays to check maximum value in a varying of operating the number of malfunctions. power voltage, not a continuous voltage. Requirement: None malfuction 2 100 m/s 2 Switching current (A) Maximum coil voltage (% of rated)