G5Q PCB Power Relay A Miniature Power Relay with 1-pole 10A Switching Capacity Compact single pole relay. Excellent switching performance for a variety of loads. Small, yet provide 8-kV impulse withstand voltage (between coil and contacts). RoHS Compliant Model Number Legend Application Examples G5Q- Ideal for output applications of control equipments. 12 3 1. Number of 2. Contact Form 3. Enclosure rating Poles None : SPDT (1c) None : Flux protection 1: 1-pole A : SPST-NO (1a) 4 : Fully-sealed G 5 Q Ordering Information Enclosure Flux protection Fully-sealed rating Minimum Terminal Contact Rated coil Rated coil packing unit Model Model Shape Classification form voltage voltage 5 VDC 5 VDC 9 VDC 9 VDC SPST-NO G5Q-1A G5Q-1A4 (1a) 12 VDC 12 VDC 24 VDC 24 VDC PCB 40 pcs/ Standard terminals 5 VDC 5 VDC tube Note. When ordering, add the rated coil voltage to the 9 VDC 9 VDC model number. SPDT G5Q-1 G5Q-14 Example: G5Q-1A 5 VDC (1c) 12 VDC 12 VDC Rated coil voltage 24 VDC 24 VDC Ratings Coil Must operate Must release Max. voltage Power Rated current Coil resistance voltage voltage Contact form Rated voltage (V) consumption (mA) () (V) (V) (mW) % of rated voltage 5 VDC 125 40 9 VDC 405 22.2 SPST-NO (1a) Approx. 200 12 VDC 720 16.7 24 VDC 2880 190% 8.3 75% max. 5% min. 5 VDC 63 (at 23C) 80 9 VDC 202 44.4 SPDT (1c) Approx. 400 12 VDC 360 33.3 24 VDC 1440 16.7 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. Note 3. The Max. voltage is the maximum voltage that can be applied to the relay coil. Contacts Load Resistive load Item SPST-NO (1a) SPDT (1c) Contact Type Single Contact material Ag-Alloy (Cd free) 10 A at 125 VAC (NO) 3 A at 125 VAC (NO) 10 A at 125 VAC 3 A at 250 VAC (NO) Rated load 3 A at 125 VAC 5 A at 30 VDC (NO) (resistive) 3 A at 250 VAC 3 A at 125 VAC (NC) 5 A at 30 VDC 3 A at 250 VAC (NC) 3 A at 30 VDC (NC) Rated carry current 10 A (NO)/3 A (NC) Max. switching 277 VAC, 30 VDC voltage Max. switching AC: 10 A (NO)/3 A (NC) current DC: 5 A (NO)/3 A (NC) 1G5Q PCB Power Relay Characteristics Item Classification Standard model Contact resistance *1 100 m max. Operate time 10 ms max. Release time 5 ms max. Insulation resistance *2 1,000 M min. Between coil 4,000 VAC, 50/60 Hz for 1 min and contacts Dielectric Between strength contacts of the 1,000 VAC, 50/60 Hz for 1 min same polarity Impulse withstand voltage 8 kV (1.2 x 50 s) (between coil and contacts) Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Vibration resistance Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 2 Destruction 1,000 m/s Shock resistance 2 Malfunction 100 m/s Mechanical 10,000,000 operations (18,000 operations per hour) NO 50,000 operations: 10 A at 125 VAC resistive load (operation: ON for 1 sec, OFF for 3 sec) 200,000 operations: 3 A at 125 VAC resistive load (operation: ON for 1 sec, OFF for 1 sec) G 100,000 operations: 3 A at 250 VAC resistive load 5 (operation: ON for 1 sec, OFF for 1 sec) Durability Q 100,000 operations: 5 A at 30 VDC resistive load Electrical (operation: ON for 1 sec, OFF for 1 sec) NC 200,000 operations: 3 A at 125 VAC resistive load (operation: ON for 1 sec, OFF for 1 sec) 100,000 operations: 3 A at 250 VAC resistive load (operation: ON for 1 sec, OFF for 1 sec) 100,000 operations: 3 A at 30 VDC resistive load (operation: ON for 1 sec, OFF for 1 sec) Failure rate (P level) 10 mA at 5 VDC (reference *3) Ambient operating -40C to 105C (with no icing or condensation) temperature Ambient operating humidity 5% to 85% Weight Approx. 6.5 g Note. The data shown above are initial values. *1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method. *2. Testing conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. *3. This value was measured at a switching frequency of 120 operations/min. Engineering Data Maximum Switching Capacity Ambient Temperature VS. Shock Malfunction Maximum Coil Voltage Y 100 200 1,000 180 160 X Z 1,000 1,000 140 120 AC resistive load (NO) NC 10 NO Contact 100 300 Contact DC resistive load (NO) 80 300 1,000 1,000 Z X AC resistive load (NC) 60 40 DC resistive load (NC) 1,000 2 20 Unit: m/s Y Sample: G5Q-14 12 VDC Shock direction 1 0 1 10 100 1000 -40 -20 0 20 23 40 60 80 85 100 120 XX Number of Relays: 5 pcs Y Test conditions: Shock is applied Switching voltgate (V) Ambient temperature (C) Z in X, Y, and Z directions three Z times each with without Y energizing the Relays to check the number of malfunctions. Requirement: None malfuction 2 100 m/s 2 Switching current (A) Maximum coil voltage (% of rated)