G5RL PCB Relay Low-profile Relay with Various Models Low profile: 15.7 mm in height Clearance and creepage distance Between coil and contacts: 8 mm/8 mm Between contacts of the same polarity: 3 mm/4 mm Models with AC coil available. High-Inrush model available (Inrush peak currents up to 100 A) Silent model available (Approx. 25% (15 dB) less sound pressure than standard G5RL-series Relay) RoHS Compliant Ordering Information Classification Enclosure ratings Contact form Contact ratings Special function SPST-NO SPDT 16 A (high capacity) AC coil Flux protection --- G5RL-1-E High inrush G5RL-1A-E-HR G5RL-1-E-HR Silent G5RL-1A-E-LN 12 A G5RL-1A-LN Note: When ordering, add the rated coil voltage to the model number. Example: G5RL-1A-LN 12 VDC Rated coil voltage Model Number Legend: G5RL- - - VDC (VAC) 12354 1. Number of Poles 4. Special Function 1: 1 pole None: Standard 2. Contact Form/Contact Construction HR: High inrush None: SPDT LN: Silent A: SPST-NO 5. Rated Coil Voltage 3. Contact Ratings Refer to Coil Ratings on page 2, 4 and 6. None: 12 A E: 16 A (high capacity) 1G5RL G5RL Models with AC Coil: G5RL-1-E Specifications Coil Ratings Rated voltage 24 VAC 100 VAC 115 VAC/120 VAC 200 VAC 230 VAC/240 VAC Rated current at 50 Hz 31.30 mA 7.50 mA 5.85 mA 6.25 mA 3.75 mA 3.00 mA 3.13 mA Rated current at 60 Hz 28.30 mA 6.88 mA 5.35 mA 5.70 mA 3.45 mA 2.76 mA 2.88 mA Coil resistance 443 8,220 11,600 33,000 47,600 Must operate voltage 75% of rated voltage Must release voltage 15% of rated voltage Max. voltage 90% to 110% of rated voltage Power consumption Approx. 0.75 VA Note: 1. The above items are measured at a coil temperature of 23C. 2. The tolerance of the rated current is +15%/20%. 3. Power consumption drop was measured at 50 Hz. 4. Coil resistances are provided as reference values. Contact Ratings Characteristics Contact form SPDT Contact resistance 100 m max. Contact material Ag alloy (Cd free) Operate time 20 ms max. Load Resistive load (cos=1) Release time 20 ms max. Rated load 16 A at 250 VAC (NO) Insulation 1,000 M min. (at 500 VDC) 16 A at 24 VDC (NO) resistance 5 A at 250 VAC (NC) Dielectric strength 6,000 VAC, 50/60 Hz for 1 min between 5 A at 24 VDC (NC) coil and contacts Rated carry current 16 A (NO), 5 A (NC) 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity Max. switching voltage 250 VAC, 24 VDC Impulse withstand 10 kV between coil and contacts (1.2 Max. switching current 16 A (NO), 5 A (NC) voltage 50 s) Max. switching power 4,000 VA, 384 W (NO) Vibration resistance Destruction: 10 to 55 to 10 Hz, 1.5-mm 1,250 VA, 120 W (NC) double amplitude Failure rate (reference value) 40 mA at 24 VDC Malfunction: 10 to 55 to 10 Hz, 1.5-mm double amplitude 6 Note: P level: = 0.1 10 operations 60 Endurance Mechanical: 10,000,000 operations min. (at 18,000 operations/h) Electrical: 50,000 operations min. (Resistive load, 16 A, 250 VAC, NO contact) (Resistive load, 16 A, 24 VDC, NO contact) (Resistive load, 5 A, 250 VAC, NC contact) (Resistive load, 5 A, 24 VDC, NC contact) Ambient Operating: 40C to 70C (with no icing) temperature Ambient humidity Operating: 5% to 85% Weight Approx. 10g Note: 1. Values in the above table are initial values. 2. The contact resistance is measured with 1 A applied at 5 VDC using a fall-of-potential method. 3. The insulation resistance is measured between coil and contacts and between contacts of the same polar- ity at 500 VDC. 2