G5RL PCB Relay Low-profile Relay with Various Models Low profile: 15.7 mm in height Clearance and creepage distance Between coil and contacts: 8 mm/8 mm Between contacts of the same polarity: 3 mm/4 mm Models with AC coil available. High-Inrush model available (Inrush peak currents up to 100 A) Silent model available (Approx. 10 to 20 dB less sound pressure than standard G5RL-series Relays) RoHS Compliant Ordering Information Classification Enclosure ratings Contact form Contact ratings Special function SPST-NO SPDT 16 A (high capacity) AC coil Flux protection --- G5RL-1-E High inrush G5RL-1A-E-HR G5RL-1-E-HR Silent G5RL-1A-E-LN 12 A G5RL-1A-LN Note: When ordering, add the rated coil voltage to the model number. Example: G5RL-1A-LN 12 VDC Rated coil voltage Model Number Legend: G5RL- - - VDC (VAC) 12354 1. Number of Poles 4. Special Function 1: 1 pole None: Standard 2. Contact Form/Contact Construction HR: High inrush None: SPDT LN: Silent A: SPST-NO 5. Rated Coil Voltage 3. Contact Ratings Refer to Coil Ratings on page 2, 4 and 6. None: 12 A E: 16 A (high capacity) 1G5RL G5RL Models with AC Coil: G5RL-1-E Specifications Coil Ratings Rated voltage 24 VAC 100 VAC 115 VAC/120 VAC 200 VAC 230 VAC/240 VAC Rated current at 50 Hz 31.30 mA 7.50 mA 5.85 mA 6.25 mA 3.75 mA 3.00 mA 3.13 mA Rated current at 60 Hz 28.30 mA 6.88 mA 5.35 mA 5.70 mA 3.45 mA 2.76 mA 2.88 mA Coil resistance 443 8,220 11,600 33,000 47,600 Must operate voltage 75% max. of rated voltage Must release voltage 15% min. of rated voltage Max. voltage 90% to 110% of rated voltage Power consumption Approx. 0.75 VA Note: 1. The above items are measured at a coil temperature of 23C. 2. The tolerance of the rated current is +15%/20%. 3. Power consumption drop was measured at 50 Hz. 4. Coil resistances are provided as reference values. Contact Ratings Contact form SPDT Contact material Ag alloy (Cd free) Load Resistive load (cos=1) Rated load 16 A at 250 VAC (NO) 16 A at 24 VDC (NO) 5 A at 250 VAC (NC) 5 A at 24 VDC (NC) Rated carry current 16 A (NO), 5 A (NC) Max. switching voltage 250 VAC, 24 VDC Max. switching current 16 A (NO), 5 A (NC) Max. switching power 4,000 VA, 384 W (NO) 1,250 VA, 120 W (NC) Failure rate (reference value) 40 mA at 24 VDC 6 Note: P level: = 0.1 10 operations 60 Characteristics Contact resistance 100 m max. Operate time 20 ms max. Release time 20 ms max. Insulation resistance 1,000 M min. (at 500 VDC) Dielectric strength 6,000 VAC, 50/60 Hz for 1 min between coil and contacts 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity Impulse withstand voltage 10 kV between coil and contacts (1.2 50 s) Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Endurance Mechanical: 10,000,000 operations min. (at 18,000 operations/h) Electrical: 50,000 operations min. (Resistive load, 16 A, 250 VAC, NO contact) (Resistive load, 16 A, 24 VDC, NO contact) (Resistive load, 5 A, 250 VAC, NC contact) (Resistive load, 5 A, 24 VDC, NC contact) Ambient temperature Operating: 40C to 70C (with no icing) Ambient humidity Operating: 5% to 85% Weight Approx. 10g Note: 1. Values in the above table are initial values. 2. The contact resistance is measured with 1 A applied at 5 VDC using a fall-of-potential method. 3. The insulation resistance is measured between coil and contacts and between contacts of the same polarity at 500 VDC. 2