Low Signal Relay G5V-1 Ultra-miniature, Highly Sensitive SPDT Relay for Signal Circuits High sensitivity: 150 mW nominal power consumption. Small size at 10 H x 7.5 W x 12.5 L mm. Switches from 1 mA to 1 A. Conforms to FCC part 68 requirements for coil to contacts. Fully-sealed construction. Ideal for use in telecommunications, security, and comput- er/peripheral equipment. RoHS Compliant. RC Ordering Information To Order: Select the part number and add the desired coil voltage rating (e.g., G5V-1-DC12). Terminal Type Contact form Contact type Construction Model PCB through-hole Standard SPDT Single crossbar Fully sealed G5V-1 Model Number Legend G5V - - DC 12 3 1. Contact Form 2. Pickup Voltage % 3. Rated Coil Voltage Blank: Standard, 80% of nominal 1: SPDT 3, 5, 6, 9, 12, 24 VDC Specifications Contact Data Load Resistive load (p.f. = 1) Rated load 0.50 A at 125 VAC, 1A 24 VDC Contact material Ag + Au-Alloy Carry current 2 A Max. operating voltage 125 VAC, 60 VDC Max. operating current 1 A Max. switching capacity 62.50 VA, 30W Min. permissible load (See note) 1 mA, 5 VDC 6 Note: P level: = 0.1 x 10 /operation 60 This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 100 . This value may vary depending on the operating environment. Always double-check relay suitability under actual operating conditions. Low Signal Relay G5V-1 45 Coil Data Rated Rated current Coil Coil inductance Pick-up Dropout Maximum Power voltage (mA) resistance (Ref. value) (H) voltage voltage voltage consumption (VDC) () (mW) Armature OFF Armature ON % of rated voltage 3 50 60 0.05 0.11 80% 10% min. 200% Approx. 150 at 23C 5 30 167 0.15 0.29 6 25 240 0.20 0.41 9 16.70 540 0.45 0.93 12 12.50 960 0.85 1.63 24 6.25 3,840 3.48 6.61 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. The operating characteristics are measured at a coil temperature of 23C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. Characteristics Contact resistance (See note 1) 100 m max. Operate time (See note 2) 5 ms max. (mean value: approx. 2.50 ms) Release time (See note 2) 5 ms max. (mean value: approx. 0.90 ms) Operating frequency (max.) Mechanical 36,000 operations/hour Electrical 1,800 operations/hour Insulation resistance (See note 3) 1,000 M min. (at 500 VDC between coil and contacts, at 250 VDC between contacts of same polarity) Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between coil and contacts 400 VAC, 50/60 Hz for 1 minute between contacts of same polarity Impulse withstand voltage 1,500 V (10 X 160 s) between coil and contacts (conforms to FCC Part 68) Vibration Mechanical durability 10 to 55 Hz, 3.30 mm double amplitude Malfunction durability 2 Shock Mechanical durability 1,000 m/s (approx. 100G) 2 Malfunction durability 100 m/s (approx. 10 G) Ambient temperature -40C to 70C Humidity 5% to 85% RH Service life Mechanical 5 million operations min. (at 18,000 operations/hour) Electrical 100,000 operations min. (under rated load,1,800 ops/hr) See Characteristic Data Weight Approx. 2 g Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method. 2. Values in parentheses are typical values unless otherwise stated. 3. The insulation resistance was measured with a 500-VDC Megohmmeter between coil and contacts and a 250 VDC megohmmeter between con- tacts with the same polarity applied to the same parts as those for checking the dielectric strength. 4. The above values are initial values. Approvals UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40C Type Contact form Coil rating Contact ratings Number of test operations G5V-1 SPDT 3 to 24 VDC 0.5A at 125 VAC (General Use) 100,000 0.3 A at 110 VDC (Resistive) 6,000 1A at 30 VDC (Resistive) Note: In the interest of product improvement, specifications are subject to change. 46 Low Signal Relay G5V-1